Labshake search
Citations for World Precision Instruments :
151 - 200 of 674 citations for 6 AMINO 4H 7H 1 3 DITHIINO 5 4 D PYRIMIDIN 8 ONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... between two custom-made suction electrodes (1.5 mm, #1B150-6, World Precision Instruments) and kept superfused with artificial cerebrospinal fluid (aCSF) ...
-
bioRxiv - Neuroscience 2023Quote: ... These were pulled from TW150F-6 micropipettes (World Precision Instruments Inc., Sarasota, FL) on a horizontal Flaming/Brown micropipette puller (Model P-87 ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Biophysics 2023Quote: ... Thin-wall capillaries (TW150F-3, World Precision Instruments, Germany) were pulled with a DMZ-universal puller (Zeitz ...
-
bioRxiv - Bioengineering 2023Quote: ... Using a microinjection pump (UMP-3; World Precision Instruments), 0.2⨉106 D425-GL cells were injected in a volume of 3 μL at 30 nL/s ...
-
bioRxiv - Bioengineering 2023Quote: ... 4 nl of the sample were delivered into the common cardinal vein using microcapillaries (TW100-4, World Precision Instruments), which were pulled using a Sutter P1000 needle puller.
-
bioRxiv - Neuroscience 2021Quote: ... was assembled prior to injections into the cortex under microscopic control using a microinjection system (UMP3-1, SYS-Micro 4; World Precision Instruments). To increase optogenetic responses after one year ...
-
bioRxiv - Cell Biology 2022Quote: ... IVT reticulocyte lysate was backloaded into a needle pulled from a 1 mm glass capillary tube (TW 100F-4, World Precision Instruments) using a P-87 Micropipette Puller (Sutter Instrument) ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
bioRxiv - Neuroscience 2020Quote: ... A small craniotomy was made (5 × 5 mm) with a microdrill (OmniDrill 35, World Precision Instruments, USA) and the margins were removed with rat skull-appropriate bone rongeurs to extend the craniotomy to accommodate a 10 mm diameter microwire array ...
-
bioRxiv - Systems Biology 2021Quote: ... 1 mM beta-glycerol phosphate and 5 mM of sodium orthovanadate) using a syringe pump (Aladdin AL-1000, World precision instruments). Livers and right kidneys were quickly removed and snap frozen in liquid nitrogen ...
-
bioRxiv - Bioengineering 2021Quote: ... The culture medium in the trachea lumen and within the chamber was refreshed via a syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and a programmable pump (flow rate ...
-
bioRxiv - Bioengineering 2021Quote: ... the culture medium within the inner space of the trachea was replaced with the fresh medium once a day using a programmable syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and the removed culture medium was collected in a waste reservoir ...
-
bioRxiv - Neuroscience 2023Quote: Intracortical injections were made at multiple sites (∼5-9 sites per cranial window, spaced 0.5-1 mm apart) using a microinjector (NanoFil, World Precision Instruments) fit with a 36G beveled needle (NF36BV-2 ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Neuroscience 2020Quote: ... Glass injection pipettes (World Precision Instruments, 1B100-4) were pulled using a Sutter P-2000 laser puller and beveled using a Narishige EG-45 grinder ...
-
bioRxiv - Physiology 2020Quote: ... A thinly pulled glass electrode (IB200F-4, WPI) back-billed with 500 mmol L-1 KCl was used as a reference ...
-
bioRxiv - Microbiology 2020Quote: ... and LabTrax 4-Channel Data Acquisition system (WPI). Finally ...
-
bioRxiv - Biophysics 2019Quote: Borosilicate capillary glasses (1B150F−4, World Precision Instruments) were pulled in a horizontal pipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... from borosilicate glass (1B200-4, WPI, Sarasota, FL). Pipettes for somatic recording had an impedance of 5-6 MΩ ...
-
bioRxiv - Genomics 2022Quote: ... Standard Glass Capillaries (1B100-4, World Precision Instruments) using a P-2000 needle puller (Sutter instruments) ...
-
bioRxiv - Neuroscience 2021Quote: ... titer: 8-10 × 1012) as described previously by using a beveled needle nanosyringe (nanofil 34G BVLD, WPI) under control of a micro injection pump (100 nl/min ...
-
bioRxiv - Microbiology 2023Quote: ... that had been prepared on a 8 mm diameter #1.5 circular glass coverslip (World Precision Instruments, Inc). The coverslip-pad-cell sample assembly was placed inverted onto the base of a 35 mm #1.5 FluoroDish (WPI)45 ...
-
bioRxiv - Bioengineering 2021Quote: ... Pulled glass capillaries (TW120-3, World Precision Instruments, Sarasota, FL) were made using a glass puller and filament (P-97 and FB315B ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass pipettes with a resistance of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Neuroscience 2020Quote: ... Mice were anesthetized with isoflurane (5% induction, 1-2 % maintenance; Aerrane, Henry Schein) and secured in a rodent stereotaxic apparatus (Model #502063, World Precision Instruments). Buprenex (Buprenorphine ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (5 % induction, 1-2 % maintenance; Aerrane, Henry Schein) and secured in a rodent stereotaxic apparatus (Model #502063, World Precision Instruments). Buprenex (Buprenorphine ...
-
bioRxiv - Neuroscience 2022Quote: ... They were filled with a 1 M KCl solution using a MicroFil non-metallic syringe needle (MF 34G-5, World Precision Instruments); a few recordings were done with 3 M KCl (no particular change was noticed).
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 1 and 5 MΩ using a MF-200 microforge (World Precision Instruments). An agar bridge (1M KCl ...
-
bioRxiv - Physiology 2019Quote: ... Ventilatory motor patterns were recorded from one of the abdominal nerve roots with a suction electrode (World Precision Instruments). The electrode was made from an unfilamented capillary tube 1 mm in diameter (World Precision Instruments ...
-
bioRxiv - Developmental Biology 2020Quote: ... One-cell-stage AB WT embryos were injected with gRNA and Ca9 mRNA with a Picopump (World Precision Instruments). Potential founders (F0 ...
-
bioRxiv - Biophysics 2020Quote: ... Recording pipettes were fabricated from the TW150-6 borosilicate glass capillaries (World Precision Instruments Inc.) using the pp830 vertical puller (Narishige International) ...
-
bioRxiv - Physiology 2020Quote: ... glass capillaries (TW-150-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL) were pulled to desired shape using a Sutter Inst ...
-
bioRxiv - Neuroscience 2022Quote: ... using a microinjector pump (UltraMicroPump3-4, World Precision Instruments). The needle was lowered over 1 min and remained in place for 1 min before infusion ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were performed with microinjector-controlled (micro-4, WPI) syringe (nanofil syringe and Nanofil 33G BVLD Needle ...
-
bioRxiv - Neuroscience 2023Quote: ... Electrical hindpaw stimulation was applied with 1 msec 5 mA current pulses using an isolated current stimulator (A382, World Precision Instruments, Sarasota, Florida). For each stimulation condition ...
-
bioRxiv - Neuroscience 2021Quote: ... The implanted GRIN lens was secured using 3 M Vetbond (WPI) on the skull ...
-
bioRxiv - Neuroscience 2021Quote: ... A borosilicate glass capillary (1B100F-3; World Precision Instruments, Sarasota, FL) was filled with 10% sucrose water and embedded into a cotton plug ...
-
bioRxiv - Neuroscience 2021Quote: ... Two sharp borosilicate glass (1B100F-3; World Precision Instruments, Sarasota, FL) electrodes were prepared using an electrode puller (P-2000 ...
-
bioRxiv - Neuroscience 2021Quote: ... A borosilicate glass capillary (1B100F-3; World Precision Instruments, Sarasota, FL) was filled with 10% sucrose water and embedded into a cotton plug ...
-
bioRxiv - Genetics 2023Quote: ... OCT was performed at 2- and 3-weeks post-injection (WPI), then 1- ...
-
A lateral protrusion latticework connects neuroepithelial cells and is regulated during neurogenesisbioRxiv - Developmental Biology 2021Quote: ... in poly-D-lysine coated glass-bottomed petri-dishes (World Precision Instruments, FD35-PDL- 100), covered with neurobasal media ...
-
bioRxiv - Biophysics 2019Quote: ... or on poly-D-lysine coated FluoroDishes (FD35-PDL-100, World Precision Instruments; Hitchin, UK) in Dulbecco’s Modified Eagle Medium (Sigma ...
-
bioRxiv - Developmental Biology 2020Quote: ... A solution containing 25 ng/µL gRNA and 100 ng/µL Cas9 mRNA or 1000 ng/µL Cas9 protein (Toolgen) was injected into one-cell-stage embryos using a pneumatic microinjector (PV830, WPI). The insertion and/or deletion (indel ...
-
bioRxiv - Neuroscience 2022Quote: ... An incision was made over the eyelid of one eye and it was injected with CTB conjugated to Alexa-647 (Mol. Probes C34778) using a nanoliter injector (WPI). The animals were perfused with 4% PFA in PBS (0.01M ...
-
bioRxiv - Developmental Biology 2023Quote: ... A solution containing 25 ng/μL gRNA and 100 ng/μL Cas9 mRNA or 1000 ng/μL Cas9 protein (ToolGen Inc.) was injected into one-cell-stage embryos using a pneumatic microinjector (PV830, WPI). To establish the foxp1b mutant ...
-
bioRxiv - Cancer Biology 2023Quote: ... 5 × 105 SUM149 cells (transduced with WPI-Luciferase) were injected into the right thoracic mammary fat pads of the Rag2−/−:IL2Rγc−/− female mice in a volume of 100 μl containing 50% Matrigel using a hypodermic syringe ...
-
Interleukin 4 controls the role of macrophages in pulmonary metastatic tumor cell seeding and growthbioRxiv - Cancer Biology 2021Quote: ... Trans-endothelial resistance was measured using EndOhm-6 chamber and EVOM2 resistance meter (World Precision Instruments) and expressed as a function of the effective surface area of the filter membrane (Ω x cm2) ...
-
bioRxiv - Neuroscience 2023Quote: ... We prepared the needles for virus injection by pulling glass pipettes (World Precision Instruments, # 1B100-6) on a puller (Narishige International ...