Labshake search
Citations for World Precision Instruments :
401 - 450 of 704 citations for 6 9 Methano 4 1 benzoxazepin 2 3H one octahydro 3 methyl 3 α 5a bta 6 bta 9 bta 9a bta 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... (4) conduction velocity – A 2.0 MΩ Parylene-coated tungsten metal stimulating electrode (TM33B20, World Precision Instruments) was positioned within the RF of interest ...
-
bioRxiv - Cell Biology 2021Quote: ... the patch pipettes were pulled from borosilicate glass capillary tubes (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes filled with 4% LY PBS solution were mounted on a microelectrode holder (WPI, PE MEH710), which was fixed on a 3-D adjustable micromanipulor (Scientifica ...
-
bioRxiv - Physiology 2021Quote: ... Reference electrodes (5-10 megaohms) were pulled using filamented capillaries (1B100F-4, World Precision Instruments, USA) and back-filled with 1 M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... 4~5 MΩ for whole-cell recording) were pulled from borosilicate capillary glass (World Precision Instruments) with a Stutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2021Quote: ... AAV virus was injected with a glass pipette using an infusion pump (Micro 4, WPI, USA). Viruses were injected bilaterally into target brain areas using the following coordinates ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass recording electrodes (outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments 1B150F-4) were pulled using a vertical puller (Narishige ...
-
bioRxiv - Physiology 2023Quote: ... Patch pipettes were pulled (PC-10, Narashige) from borosilicate glass tubes (TW150F-4, World Precision Instruments) and heat polished at the tip using a microforge (MF-200 ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were initially anesthetized with 4% isoflurane and fixed in a stereotaxic frame (#504926, WPI, Germany) at 2% isoflurane ...
-
bioRxiv - Plant Biology 2023Quote: ... The measured data were acquired by a Lab-Trax-4 device (World Precision Instruments, Sarasota, USA) working with LabScribe2 software ...
-
bioRxiv - Physiology 2023Quote: ... The final injection mix was loaded using a pulled capillary needle (1B100F-4, World Precision Instruments) and injected into the germline of N2 young adults ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings from these cells were obtained with glass pipettes (World Precision Instruments 1B150F-4) filled with a solution containing (in mM ...
-
bioRxiv - Physiology 2024Quote: ... Ion-selective electrodes were fashioned from borosilicate glass (TW150-4; World Precision Instruments, Sarasota, FL, USA), pulled on a Flaming-Brown P-1000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... and/or Day 2 of subculture using the EVOM2 voltohmmeter (World Precision Instruments) with STX2 chopstick electrodes (World Precision Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... AAV-containing solution was infused using a 34-gauge needle (NF34BV-2, WPI) connected to a 10µL Nanofil Syringe (NANOFIL ...
-
bioRxiv - Genetics 2023Quote: ... 2 nl of this mix using a pneumatic system (pneumatic pico pump, WPI) and glass capillaries (Zebrafish-injection-pipettes blunt ...
-
bioRxiv - Neuroscience 2020Quote: Patch clamp pipettes were pulled from borosilicate capillaries (1B120F-4, World Precision Instruments, Inc., Sarasota, FL, USA) with a horizontal puller (P-87 ...
-
bioRxiv - Biophysics 2019Quote: ... An ACSF-filled glass pipette (opening diameter 10-30 µm, 1B120F-4, World Precision Instruments, Sarasota, FL) was used for Schaffer collateral nerve stimulations ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Microinjection needles were created from glass capillary tubes (058 mm inner diameter; World Precision Instruments, 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Neuroscience 2022Quote: ... and controlled by a micromanipulator connected to a pneumatic picopump (4 psi, World Precision Instruments, SYS-PV820). Constant circulation of aCSF was maintained in the dish during the recording ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipettes with 4.5-6.5 MΩ tip resistance were prepared from borosilicate glass capillaries (TW150F-4, WPI) using micropipette pullers (HEKA PIP 6 and MDI PMP102) ...
-
bioRxiv - Cell Biology 2023Quote: ... Microinjection was performed using borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA). 200-250 HeLa cells transfected with si-NC or si-METTL3 at a concentration of 25 nM were injected directly into the middle of the yolk sac of the larva ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by AAV injections using a micro-syringe connected to a micropump (UltraMicroPump 4, WPI surgical instruments), which was lowered into the brain until it reached the DV coordinates (see below for details) ...
-
bioRxiv - Biochemistry 2023Quote: ... The samples were electrosprayed from gold-coated borosilicate glass capillaries Kwik-Fil 1B120F-4 (World Precision Instruments) prepared in-house essentially as described before (49 ...
-
bioRxiv - Developmental Biology 2024Quote: ... with needles pulled using a Model P-1000 Flaming Brown Micropipette Puller (World Precision Instruments, TW100F-4). Needles were cut to yield an injection volume of ∼1nL.
-
bioRxiv - Neuroscience 2020Quote: ... Recording pipettes (resistance of 4-7 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette consisted of 5 barrels in an H configuration (World Precision Instruments, catalogue no. 5B120F-4) with the tip broken to a diameter of 30–40 μm [37] ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Microinjection needles were prepared from glass capillary tubes (0.58 mm inner diameter; World Precision Instruments, FL; 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Microbiology 2020Quote: Fly injections were carried out with microinjection needles produced from borosilicate glass capillaries (World Precision Instruments TW100-4) and a needle puller (Model PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... A micro-holding device62 was used to keep in the same coordinate the borosilicate capillary (1B150F-4, WPI) containing the LFP electrode and the optic fibre ...
-
bioRxiv - Neuroscience 2024Quote: ... Neurons were harvested using a thin wall glass capillary tube (4 inch, OD 1.0 MM, World Precision Instruments) into EBSS in a non-stick Eppendorf tube and kept on ice until dissociation.
-
bioRxiv - Neuroscience 2023Quote: ... and DVB soma were patched using 15-20 MΩ-resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Physiology 2022Quote: ... pulled from glass tubes (1.12 mm inner / 2 mm outer diameter, World Precision Instruments) and bent at 30 ° to allow near-parallel alignment of the fibres with the bottom of the experimental chamber ...
-
bioRxiv - Neuroscience 2023Quote: ... Bilateral infusions were achieved using a 35-gauge needle (World Precision Instruments NF35BV-2) and a 10 μL Hamilton Syringe (World Precision Instrument NANOFIL) ...
-
bioRxiv - Developmental Biology 2022Quote: ... It is connected to working solutions kept at 37 °C via a 4-channel peristaltic pump (WPI, PERIPRO-4LS). Lower GI tract was harvested and transferred to the organ bath with the Krebs buffer was flowing through ...
-
bioRxiv - Physiology 2019Quote: ... Hemolymph Na+ and K+ concentrations were measured using ion-selective borosilicate microelectrodes (TWI150-4, World Precision Instruments, Sarasota, USA). No interference from the FITC-dextran was found when measuring ions ...
-
bioRxiv - Neuroscience 2021Quote: ... DV -5.7) at a rate of 50 nl/minute using a microinjector-controlled syringe (micro-4, World Precision Instruments) and needle (Nanofil 33G beveled needle ...
-
bioRxiv - Neuroscience 2022Quote: ... D/V = −4) using 10 μl NanoFil syringes equipped with 33 gauge beveled NanoFil needles (World Precision Instruments, Inc.) at a volume of 0.7 μl and a rate of 0.1 μl per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled from filament-containing borosilicate glass capillaries (TW150F-4; World Precision Instruments Inc., Sarasota, FL, USA) using a Flaming/Brown Micropipette Puller (Model P-97 ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal extracellular recordings from the axons of the antennal nerve were made with glass microelectrodes (1B100F–4, WPI Inc.) filled with 0.15 M sodium chloride and inserted at the scape-pedicel joint ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp recordings were performed with pipettes pulled (Sutter P-97) using borosilicate capillary tubes (WPI Cat # 1B150F-4) with open tip resistances of 20 +/- 3 MΩ filled with internal solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... +2.5 mm L/M and −3.0 mm D/V using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4). Glass micropipettes were mounted to the stereotaxic frame via specialized connectors and attached ...
-
bioRxiv - Cell Biology 2024Quote: ... Resistance measurements were performed 4 days later in triplicate using an EVOM Epithelial Volt/ohm meter (World Precision Instruments). The values represent the average of three replicates minus the background resistance ...
-
bioRxiv - Neuroscience 2019Quote: ... pH 7.4) was infused over 2 min using a micro-injection system (World Precision Instruments). The needle was left in place for an additional 8 min after the injection ...
-
bioRxiv - Neuroscience 2020Quote: ... driven by a digital Micro2T controller (Model UMP3T-2; World Precision Instruments, Sarasota, FL, USA). After each injection ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell voltage-clamp recordings were obtained using borosilicate glass pipettes (2-5 MΩ; WPI) filled with intracellular solution containing the following (in mM) ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Anterior chambers were cannulated with 33-gauge beveled needles (NanoFil, NF33BV-2, World Precision Instruments) attached to micro-manipulators and equilibrated for 30 minutes at 9 mmHg ...