Labshake search
Citations for World Precision Instruments :
151 - 200 of 477 citations for 5 Pyrimidinecarbonitrile 2 4 diamino 6 methyl since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2020Quote: ... The resulting 1D channels of 5 μm height and 5 μm width were sealed in 35-mm glass bottomed cell culture dishes (World Precision Instruments, Sarasota, FL, USA) using plasma surface activation ...
-
bioRxiv - Biophysics 2019Quote: ... The resultant channels of 5 μm height and 5 μm width was attached in 35mm glass bottom cell culture dishes (World Precision Instruments, Sarasota, FL, USA) by plasma surface activation ...
-
bioRxiv - Developmental Biology 2021Quote: ... thin wall glass capillary needles with filament (World Precision Instruments #TW150F-4) were pulled with program 4 “Pro-Nuclear Injection” (Heat ...
-
bioRxiv - Neuroscience 2020Quote: ... Borosilicate capillaries for VTA/SNC (1B150F-4, World Precision Instruments, Friedberg, Germany) and ITC injections (marked 1 to 5 μl ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes were pulled from borosilicate glass (PG10150-4, World Precision Instruments) and filled with intrapipette solution (35 mM K-gluconate ...
-
bioRxiv - Biophysics 2022Quote: ... a PDMS block with a 4 mm punched (504651 World Precision Instruments) through hole was bonded on a cleaned coverslip ...
-
bioRxiv - Neuroscience 2019Quote: ... and controlled by a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3-4). The syringe was left in place for an additional 10 minutes following injection to facilitate viral spread ...
-
bioRxiv - Cancer Biology 2020Quote: ... thin wall glass capillary needles with filament (World Precision Instruments #TW150F-4) were pulled with program 4 “Pro-Nuclear Injection” (Heat ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording electrodes were prepared from borosilicate filaments (TW150-4, World Precision Instruments) on a P-97 Sutter Instrument micropipette puller and had a resistance of 3 – 6 MΩ ...
-
bioRxiv - Cell Biology 2024Quote: ... Injection was performed with glass capillary needles (World Precision Instruments, 1B100-4), pulled on a micropipette puller (Sutter Instrument ...
-
bioRxiv - Physiology 2024Quote: ... Glass capillaries for microelectrodes (TW150-4, World Precision Instruments, Sarasota, FL, USA) and reference electrodes (1B200F-4 ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (4-8MΩ) were made from borosilicate glass (World Precision Instruments) using a Sutter Instruments P-97 model puller.
-
bioRxiv - Neuroscience 2021Quote: ... a volume of 300 nL of AAV9-cFos-tTa + TRE-EYFP viral cocktail was bilaterally injected at 200 nL/min using a micro-infusion pump for each coordinate (2×300 nL for dDG and 2×300 nL for BLA) (UMP3; World Precision Instruments). After injection was complete ...
-
bioRxiv - Developmental Biology 2021Quote: ... The microelectrode and a reference electrode (WPI, DRIREF-2) were then mounted onto the micromanipulator (Narishige MO-202D ...
-
bioRxiv - Neuroscience 2023Quote: ... A 2 MΩ tungsten electrode (World Precision Instruments, TM33A20) driven by a Sutter manipulator was inserted into the depth of TG (around 5 - 6 mm below brain surface) ...
-
bioRxiv - Neuroscience 2023Quote: ... and 35G NanoFil beveled needle (WPI; Catalog# NF35BV-2). The volume of AAVs was 500-1000 nL at the rate 50-100 nL per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... fit with a 36G beveled needle (NF36BV-2, WPI). A high-titre solution of viral vector (AAV9-syn-jGCaMP7f-WPRE ...
-
bioRxiv - Neuroscience 2023Quote: ... electrolytic lesions of 10 μA during 5 s(Stimulus Isolator, WPI) to identify electrode bundle tip location were performed prior to PFA perfusions ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3×5 mm2 craniotomy was drilled (Omnidrill35, World Precision Instruments) over an area covering the monocular and binocular primary visual (V1m and V1b ...
-
bioRxiv - Neuroscience 2023Quote: ... the 5-V trigger is sent to a picopump (WPI, PV830) connected to a 2-mm diameter plastic tube that terminates in a glass capillary to deliver pressurized air to the mouse whiskers.
-
bioRxiv - Neuroscience 2021Quote: ... ACSF or 6-OHDA solution were loaded to a 10 µl NanoFil syringe (World Precision Instruments Inc., Sarasota, FL, USA) with a 35G blunt needle ...
-
bioRxiv - Neuroscience 2021Quote: ... Stimulation pipettes were made from 1.50 OD/1.02 ID thick septum theta borosilicate glass capillaries (TST150-6; World Precision Instruments) using a P-97 micropipette puller and filled with ACSF ...
-
bioRxiv - Neuroscience 2023Quote: ... Injection micropipettes were pulled from glass capillary tubes (1B100F-4, World Precision Instruments) and backfilled with virus and then mineral oil and mounted on a Hamilton syringe ...
-
bioRxiv - Developmental Biology 2023Quote: ... Borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA) were used for injection ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes were obtained from borosilicate glass filaments (TW150-4, World Precision Instruments) pulled on a P-97 Micropipette Puller (Sutter Instruments) ...
-
bioRxiv - Bioengineering 2023Quote: ... or saline (1xPBS) were loaded into pulled borosilicate glass micropipettes (WPI #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter after formulation with sterile-filtered components ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were fabricated from borosilicate glass capillaries (TW150F-4, World Precision Instruments) using a P-97 Flaming/Brown micropipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were fabricated from borosilicate glass capillaries (TW150F-4, World Precision Instruments) using a P-97 Flaming/Brown micropipette puller (Sutter Instruments) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Concentrated cell suspension was loaded into a microcapillary (World Precision Instruments, TW100-4) connected to a FemtoJet 4x (Eppendorf) ...
-
bioRxiv - Bioengineering 2020Quote: ... 2×104 sGFP sender and 2×104 αGFP receiver cells were seeded into 35-mm FluoroDish Cell Culture Dishes (World Precision Instruments, FD35-100) and immediately imaged under a DeltaVision OMX (GE Healthcare ...
-
bioRxiv - Neuroscience 2019Quote: ... A Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was inserted into the brain and the virus was injected at a rate of 25 nl/min using Microsyringe Pump (World Precision Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... through a 33G beveled needle (World Precision Instruments, # NF33BV-2), controlled by a micro-syringe pump (World Precision Instruments ...
-
Social Regulation of Egg Size Plasticity in the Honey Bee is Mediated by Cytoskeleton Organizer Rho1bioRxiv - Evolutionary Biology 2022Quote: ... coupled with a 35G needle (NF35BV-2; World Precision Instruments). Injected queens were given time to recover and placed back into their original colonies ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 33-gage beveled Nanofil needle (NF33BV-2, WPI). The syringe was mounted into a motorized microinjector (UMP3T-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... and a microinjection syringe pump (UMP3T-2 World Precision Instruments). Animals received 250 µL of saline for post-surgery hydration.
-
bioRxiv - Neuroscience 2023Quote: ... a Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was slowly inserted into the CA1 region (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... Females: scaled*0.95) using a 33g needle (NF33BV-2, WPI). During the same surgery ...
-
bioRxiv - Neuroscience 2022Quote: ... 400 nl of BDA were injected at a rate of 80 nl/min and a depth of 0.7 mm into each of 6 injection sites with a microinjector (WPI, Nanoliter 2010) using the fine glass pipets ...
-
bioRxiv - Neuroscience 2019Quote: ... as the guide tube and a glass capillary tube (PG52165-4; World Precision Instruments) as the flow cell ...
-
bioRxiv - Neuroscience 2020Quote: ... was placed partially inside a capillary tube (#1B120F-4; World Precision Instruments; Sarasota, FL) and then saturated with tastant ...
-
bioRxiv - Neuroscience 2020Quote: ... Glass pipettes were pulled from borosilicate glass capillary tubes (1B150F-4; World Precision Instruments) using a two-stage ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes were pulled from borosilicate glass capillary tubes (1B150F-4; World Precision Instruments) using a programmable microelectrode puller (P-97 ...
-
bioRxiv - Developmental Biology 2022Quote: Microinjections were performed using a borosilicate glass capillary needle (World Precision Instruments, TW100F-4) connected to a Pneumatic Picopump injector (World Precision instruments) ...
-
bioRxiv - Genetics 2022Quote: ... with needles drawn out from borosilicate glass capillaries (1B100-4; World Precision Instruments, Inc.) and filled with a Microfil 28 needle (MF28G67-5 4 ...
-
bioRxiv - Physiology 2022Quote: ... Glass pipette tips were created from glass rods (World Precision Instruments, Inc., 1B120F-4) using a Narshige pipette puller (Model PC-100 ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass capillary tubes (Kwik-Fil 1B150F-4, World Precision Instruments, Hitchin, United Kingdom) were pulled using a Model P90 micropipette puller (Sutter instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... Before activating the micropump (MicroSyringe Pump Controller, Micro 4 ™, World Precision Instruments, Inc.) for the injection ...
-
bioRxiv - Neuroscience 2023Quote: Thick-walled borosilicate glass pipettes (World Precision Instruments; Sarasota, Fl, USA; Cat# 1B150F-4) were pulled using a Narishige PP-830 electrode puller (Tokyo ...
-
bioRxiv - Neuroscience 2023Quote: ... Neurons were patched using ∼20 MΩ-resistant borosilicate pipettes (1B100F-4; World Precision Instruments). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Neuroscience 2023Quote: ... patch pipettes were pulled from borosilicate glass capillary tubes (TW150-4; World Precision Instruments) using a PC-10 pipette puller (Narishige) ...