Labshake search
Citations for World Precision Instruments :
401 - 449 of 449 citations for 4 nitro 5 ethyl 2 methylpyridine n oxide since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Electrical hindpaw stimulation was applied with 1 msec 5 mA current pulses using an isolated current stimulator (A382, World Precision Instruments, Sarasota, Florida). For each stimulation condition ...
-
bioRxiv - Neuroscience 2022Quote: ... cells were treated with 12-h αSN-AGs (5% v/v) for 16 h and TEER was measured using the EVOM2 apparatus with STX2 chopstick electrodes (World Precision Instruments, USA).
-
bioRxiv - Neuroscience 2023Quote: ... Bipolar stimulation electrodes were placed on the unopened spinal cord to transmit low-intensity (5–8 V) electrical pulses generated by an isolated stimulator (A 360, WPI, Sarasota, FL, USA). This allowed antidromic activation of the M-cell axons ...
-
bioRxiv - Microbiology 2019Quote: ... and sporozoites were injected intradermally into the ear pinna in a total volume of 0.2 μl using a NanoFil-10 μl syringe with a NF33BV-2 needle (World Precision Instruments). All sporozoite injections were completed within 30 min of salivary gland dissection to ensure that imaging and parasite conditions remained constant ...
-
bioRxiv - Microbiology 2019Quote: ... falciparum sporozoites were then injected into the dermis in a total volume of 0.2 μl using a NanoFil-10 μl syringe with a NF33BV-2 needle (World Precision Instruments). The human skin was then moistened with RPMI medium ...
-
bioRxiv - Neuroscience 2021Quote: ... +/−2.6mm ML, −4.5mm DV) using a 10μL syringe (nanofil, World Precision Instrument, USA) with NanoFil Needle (NF33BV-2, World Precision Instruments, USA) at a rate of 100nL/min (Micro4 pump ...
-
bioRxiv - Neuroscience 2021Quote: ... then mounted lateral-side up on a thin layer of 1.5-2% low-melt agarose in a tissue culture dish with a cover-glass bottom (World Precision Instruments) and covered in E3 media ...
-
bioRxiv - Neuroscience 2021Quote: ... A long tempered small tip (2 — 3 μm in diameter) patch pipette (∼3 MΩ; borosilicate glass, WPI, GBF 150-86-10) was used to pressure inject the dye into the extracellular space at 4 — 6 psi for 14 minutes ...
-
bioRxiv - Neuroscience 2020Quote: ... VP neurons were visualized using an Olympus BX51WI microscope and recorded from using glass pipettes (1.3-2 MΩ, World Precision Instruments) filled with internal solution (in mM ...
-
bioRxiv - Bioengineering 2022Quote: ... a 2-mm diameter craniotomy was then made over the fiducial mark and covered with KwikCast (World Precision Instruments, FL, USA). The mouse then recovered overnight before the recording session.
-
bioRxiv - Cell Biology 2022Quote: ... TEER was measured with was monitored daily using an epithelial tissue volt ohmmeter (EVOMX) with STX-2 chopsticks (World Precision Instruments). TEER measurements were calculated in ohms cm2 after subtracting the blank value for the membrane insert ...
-
bioRxiv - Neuroscience 2023Quote: ... 1474) and a 75-200 nL volume of viral vector was injected using a microinjector pump (World Precision Instruments, UMP3T-2) with an attached 10-μL NanoFil syringe (World Precision Instruments ...
-
bioRxiv - Cell Biology 2023Quote: ... was injected using a 5-µl Hamilton syringe at a rate of 0.25µl/min during 2 min with a mini-pump (UltraMicroPump III, World Precision Instruments, USA). The same volume of the dye Evans Blue (Sigma ...
-
bioRxiv - Cancer Biology 2023Quote: ... A suspension of 100,000 cells/2 µl/injection was then slowly injected using an UltraMicroPump III and a Micro4 Controller (World Precision Instruments). Post-surgical pain was controlled with SQ carprofen ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...
-
bioRxiv - Neuroscience 2019Quote: Eight to eleven weeks old injected mice were anesthetized with 5% of isoflurane a 1.5% of oxygen into the anesthesia system box (World Precision Instruments, Ref. EZ-B800) for 5 minutes ...
-
bioRxiv - Physiology 2021Quote: The mixed sample was then transferred to a 5 mL syringe and perfused using an Aladdin AL-1000 syringe pump (World precision instruments, United Kingdom) through the ibidi slide ...
-
bioRxiv - Cell Biology 2023Quote: ... The micropipette was bent to a desired degree by heating it over an alcohol lamp and was filled with phosphate-buffered saline (PBS) using the MicroFil (World Precision Instruments, MF34G-5). The micropipette was installed to a micropipette holder ...
-
bioRxiv - Neuroscience 2022Quote: Mice were anesthetized with 3% isoflurane (Aerrane, Henry Schein) for 2 min and then transferred to the stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% and monitored the same way as described above for IHKA injection ...
-
bioRxiv - Neuroscience 2021Quote: ... was inserted in the dorsal horn to carefully deliver CAV virus at 2 nl/s with the aid of electronically controlled nanoinjector (Nanoliter 2010, WPI, FL, US). Three injections ...
-
bioRxiv - Neuroscience 2022Quote: ... for 2 min in a rectangular transparent plexiglass box (induction chamber) and then transferred to a stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% ...
-
bioRxiv - Microbiology 2021Quote: ... The dorsal side of their ears was then either exposed to mosquito bites for two minutes or injected with 0.2 μL of sporozoite suspension using a micro syringe (NanoFil 10 μL syringe mounted with a 35G beveled needle, World Precision Instruments), yielding fields of view containing in average 100 parasites ...
-
bioRxiv - Neuroscience 2021Quote: ... 40 nl of one of the viral vectors listed above at a titer of 2*1012 particles/ml was injected per site (PMd, amv dlPAG) using a 10 μl nanofil syringe (World Precision Instruments) at 0.08 μl/min ...
-
bioRxiv - Genetics 2020Quote: ... phenol red was injected into the yolk of 1- to 2-cell-stage embryos with a Pneumatic PicoPump pv280 (World Precision Instruments). After injection ...
-
bioRxiv - Neuroscience 2021Quote: ... Approximately 1 µl (2 x 1010 GC/hemisphere) virus was dispensed using a NanoFil syringe with a 33G beveled needle (World Precision Instruments). The other hemisphere was injected in the same way ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings from GPe neurons were obtained using micropipettes (2–4MΩ) made from 1.5 mm OD/1.12 mm ID borosilicate glass with a filament (World Precision Instruments, Sarasota, FL) pulled with a P-97 puller (Sutter Instruments Novato ...
-
bioRxiv - Neuroscience 2023Quote: ... Three circular glass coverslip (2 of 3 mm and one 4mm coverslips) was affixed with a clear silicone elastomer (Kwik-sil, World Precision Instruments). A custom 3D-printed stainless steel headpost was attached on the skull and the rest of exposed skull area and the edge of the cranial window were covered using a dental acrylic (C&B Metabond) ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus solution (0.4-0.6 µL) was injected at a rate of 2 nL/s with a microinjection pump (either Neurostar NanoW or WPI NanoLiter 2010). The pipette was slowly withdrawn at least 10 minutes after the completion of the injection ...
-
bioRxiv - Cell Biology 2024Quote: ... and injected with 3 μl of AAV9-hSyn-iCre (titer 1 x 1013 to 2 x 1014) into the right lateral ventricle using a nanoliter injector (World Precision Instruments; Micro4 MicroSyringe Pump Controller connected with Nanoliter 2000 ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Neuroscience 2020Quote: ... with a 33-G beveled needle that was mounted into a motorized microinjector (Legato130, KD Scientific or UMP3T-2, WPI, Sarasota, FL, USA). Other surgical procedures and viral injection was as described previously (15).
-
bioRxiv - Neuroscience 2020Quote: ... at a rate of 0.2 μL/min with a glass micropipette connected to a Hamilton syringe controlled by stereotaxic syringe holder (SYS-Micro4, WPI, Sarasota, FL, USA). The needle was removed 10 min later ...
-
bioRxiv - Molecular Biology 2023Quote: The trans-epithelial electric resistance (TEER) was tracked using the EVOM voltohmmeter equipped with STX-2 chopstick electrodes (World Precision Instruments, Stevenage, UK) during wet (days −3 ...
-
bioRxiv - Neuroscience 2023Quote: ... fluoxetine was intracranially delivered with a volume of 58.7 nl/side over 2 min using a motorized single pressure syringe pump (World Precision Instruments, Sarasota, FL). After infusion ...
-
bioRxiv - Cancer Biology 2023Quote: ... a custom-made EEG adapter with attached wires (2 recording channels, one reference, each made from Teflon-coated silver (WPI, Sarasota, FL, USA) wire with ∼0.5mm tips exposed ...
-
bioRxiv - Bioengineering 2023Quote: ... Pupils were dilated and sub-retinal injections of 2 µL were performed using a Nanofil syringe with a 28-gauge blunt needle (World Precision Instruments, Inc.) under an operating microscope (Leica Microsystems ...
-
bioRxiv - Neuroscience 2023Quote: ... covered with cells was placed between two plates and an oscillatory pressure-driven fluid flow was propelled through it using 5 mL syringes (Terumo®) mounted on a programmable double syringe pump (AL-4000; World Precision Instruments®, Hertfordshire, UK). The flow rates of 22.45 mL/min and 4.49 mL/min at 0.5 Hz were used to obtain a shear stress magnitude of 0.1 and 0.5 Pa ...
-
bioRxiv - Cell Biology 2021Quote: ... Transendothelial electrical resistance (TER) was measured daily using an EVOM volt ohm meter equipped with STX-2 electrodes (World Precision Instruments, Sarasota, FL, USA) and electrical resistance calculated as previously described (Bartosova et al. ...
-
Validating Minimally Invasive Laser Doppler Flowmetry for Serial Bone Perfusion Measurements in MicebioRxiv - Bioengineering 2019Quote: ... was placed directly on the exposed bone surface (Fig. 2) and held in place using a micromanipulator (MM3-ALL, World Precision Instruments, Sarasota, FL) to reduce signal noise from probe movement ...
-
bioRxiv - Neuroscience 2021Quote: ... The pipette was filled from the back end with mineral oil and attached to a syringe needle mounted in a microinjection syringe pump (World Precision Instruments, UMP3T-2). Before injection ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were subject to nano-electrospray ionization (nESI) in positive ion mode (at ∼2 kV) with a pulled nanospray tip (World Precision Instruments 1B100-3) prepared as detailed in (48) ...
-
bioRxiv - Neuroscience 2023Quote: ... the vagus nerve was mechanically stabilized on the micro-cuff electrode by applying a drop of 2-component silicone (Kwik-Sil, World Precision Instruments, Sarasota, FL) and then sectioned either caudal or rostral to the cuff ...
-
bioRxiv - Neuroscience 2023Quote: ... Infusions were made at a rate of 100 nL/min utilizing 29 Ga microinjection needles connected to FEP tubing secured to a 2 µl Hamilton syringe and a microinjection pump (UMP3, World Precision Instruments, Sarasota, FL). The infusion system was filled with distilled water and separated from the infused virus or drug by a small air bubble ...
-
bioRxiv - Neuroscience 2024Quote: ... the stock solution was further diluted to 0.6 mM with saline and 2 µl of the diluted solution was intracerebroventricularly administered after the control recording sessions using a NANOFIL micro-syringe (World Precision Instruments; FL, U.S.A.) and ultra-micro pomp (UMP3T-1 ...
-
bioRxiv - Neuroscience 2020Quote: ... The CO2 stimulus was pulsed through a separate delivery system that delivered controlled pulses using a PSM 8000 microinjector (WPI, Sarasota, FL., variable 5 mL s−1) into the same humidified airstream ...
-
bioRxiv - Microbiology 2022Quote: Consumption of O2 was measured using an ISO-OXY-2 O2 sensor attached to an APOLLO 4000 free radical analyzer (World Precision Instruments, Inc., Sarasota, FL) as described52 ...
-
bioRxiv - Neuroscience 2023Quote: ... The space between the edges of the foil and the head capsule of the fly was sealed with 2-component silicon (Kwik-Sil™, World Precision Instruments, Sarasota, USA). A droplet of Ringer’s solution (NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus (AAV1/2-OXTp-hM4Dgi-mCherry or AAV1/2-OXTp-Venus or AAV1/2-OXTp-mCherry) was loaded into a 20μl NanoFil syringe fitted with a 33gauge needle (cat no. NF33BL, World Precision Instruments Inc, Sarasota, FL, USA). A final volume of 270nl was injected into the PVH (A-P −1.7mm ...
-
bioRxiv - Biophysics 2021Quote: ... to block or enhance a specific pathway the ear surface was gently cleaned and dried and a 4 µl solution containing a selected drug (Table 2) diluted in a PBS was microinjected in the earlobe skin using a 10 µl NANOFIL syringe (World Precision Instruments Inc., Sarasota, FL, USA) equipped with a gauge 33 needle ...