Labshake search
Citations for World Precision Instruments :
1 - 50 of 484 citations for 3 Chloro 5 fluoro 4' morpholinomethyl benzophenone since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: For GBA quantification (n=5 for 4 WPI, n=3 for 8 WPI), the surface function of the Imaris software was used to select only GFP-positive cells by appropriately adjusting the number of voxels as well as the intensity of the GFP channel in the threshold tab ...
-
bioRxiv - Neuroscience 2021Quote: For GBA quantification (n=5 for 4 WPI, n=3 for 8 WPI), the surface function of the Imaris software was used to select only GFP-positive cells by appropriately adjusting the number of voxels as well as the intensity of the GFP channel in the threshold tab ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass pipettes were used with a resistance of 3-5 MΩ (1B150F-4; WPI). Patch clamp recordings were acquired and filtered at 10 kHz with the internal Bessel filter using a Multiclamp 700B (Molecular Devices ...
-
bioRxiv - Neuroscience 2022Quote: ... or 23mm well fluoro dishes (World Precision Instruments). The intracellular free calcium concentration ([Ca2+]i ...
-
bioRxiv - Developmental Biology 2022Quote: ... on Fluoro-Dish glass bottom dishes (World Precision Instruments). Images were acquired using a Leica DFC7000T camera mounted on a Leica M165FC stereomicroscope and LAS X software (Leica).
-
bioRxiv - Neuroscience 2021Quote: ... The patch electrodes (3-4 MΩ, World Precision Instruments; 1B150F-3) were filled with intracellular solution containing ...
-
bioRxiv - Neuroscience 2023Quote: ... Mice were anesthetized using 4% isoflurane (Piramal) in 100% O2 for 3 to 5 min (World Precision Instruments, Small Animal Anesthesia System ...
-
bioRxiv - Cell Biology 2024Quote: ... using 3-4 MΩ glass pipettes (WPI) pulled with a PC100 puller (Narishige ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass pipettes (3-4 MΩ resistance, World Precision Instruments (Sarasota, FL)) were filled with an intracellular solution containing the following ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3×5 mm2 craniotomy was drilled (Omnidrill35, World Precision Instruments) over an area covering the monocular and binocular primary visual (V1m and V1b ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording electrodes (3–4 MΩ) were pulled from thin-walled borosillicate glass (TW150F-4; World Precision Instruments, Sarasota, FL) and filled with (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... with patch pipettes (2-3 MΩ) pulled from borosilicate pipettes (TW150-4, WPI, USA) using PC-10 puller (Narishige ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes of 4-6 MOhm resistance (borosilicate glass, World Precision Instruments, no. TW150F-3) were prepared on Narishige (PP-830 ...
-
bioRxiv - Neuroscience 2023Quote: Voltage clamp recordings were performed using 3-4 MΩ patch pipettes (WPI; Sarasota, FL), which were pulled from borosilicate glass on a P-97 pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... neurons are sparsely plated in 3-4 spots on 35mm plates (Fluorodish, World Precision Instruments) coated with PDL/Laminin ...
-
bioRxiv - Neuroscience 2023Quote: ... Animals were injected into their foot with 3-5 µL of 10-5 M ELH using a 10 µL Nanofil syringe (World Precision Instruments) equipped with a 35-gauge needle ...
-
bioRxiv - Developmental Biology 2023Quote: ... Ventral longitudinal muscle 6 in abdominal segments 3 or 4 was impaled with two intracellular electrodes (1 mm outer diameter borosilicate capillaries; World Precision Instruments, 1B100F-4) of ∼15 MΩ resistance (3M KCl) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance between 3-5 MΩ were pulled from borosilicate glass (WPI) with a Sutter-87 puller (Sutter) ...
-
bioRxiv - Neuroscience 2020Quote: ... 200 nl of drug were injected in mice (n=3) using a microinjector (Micro 4, WPI) via Hamilton syringe connected to a cannula using tygon tubing at a rate of 200 nl/15s as we previously described in Gao and colleagues18.
-
bioRxiv - Genetics 2022Quote: ... and filled with a Microfil 28 needle (MF28G67-5 4; World Precision Instruments, Inc.). The chorion of Sciara is very thin and does not need to be removed for injection ...
-
bioRxiv - Bioengineering 2022Quote: ... The needle was allowed to sit in place for approximately 5 min and 3-5 μL of viral vector was injected using a microsyringe pump (World Precision Instruments, UMP3) and pump controller (World Precision Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes with a resistance of 4-5 MΩ were pulled from borosilicate capillaries (WPI, USA) in a horizontal puller (P1000 ...
-
bioRxiv - Neuroscience 2021Quote: Low-resistance patch electrodes (3–4 MΩ) were pulled from filamented borosilicate patch electrodes (World Precision Instruments, USA) with a PC-100 micropipette puller (Narishige ...
-
bioRxiv - Neuroscience 2023Quote: ... electrodes (2-3 MΩ tip resistance) were pulled from cleaned borosilicate glass capillaries (TW150F-4, World Precision Instruments), their tips were silanized using 5% dichlorodimethylsilane at 220 °C for 30 min and stored in a desiccator ...
-
bioRxiv - Physiology 2021Quote: ... Reference electrodes (5-10 megaohms) were pulled using filamented capillaries (1B100F-4, World Precision Instruments, USA) and back-filled with 1 M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... 4~5 MΩ for whole-cell recording) were pulled from borosilicate capillary glass (World Precision Instruments) with a Stutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording electrodes were typically 3-5 MΩ size and were pulled from borosilicate glass (World Precision Instruments). The intracellular solution used had the following composition (in mM) ...
-
bioRxiv - Physiology 2023Quote: ... a pressure pipette (OD 3–4 μm) attached to a micropressure system (model 900A; World Precision Instruments, Sarasota, FL) was inserted into an early proximal segment ...
-
bioRxiv - Neuroscience 2022Quote: ... patch pipettes with a resistance of 3~5 MΩ were made from borosilicate glass (World Precision Instruments, Sarasota, FL) with a Sutter Instrument P-97 micropipette puller (Novato ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained from NAc shell MSNs using borosilicate glass pipettes (3-5 ΩM; WPI) filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled to resistances of ∼3 MΩ from thin-walled glass capillaries (World Precision Instruments, Cat# 1B120F-4). Importantly ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette consisted of 5 barrels in an H configuration (World Precision Instruments, catalogue no. 5B120F-4) with the tip broken to a diameter of 30–40 μm [37] ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2024Quote: ... We used 3−5 MΩ glass patch pipettes (capillary tubing with 1.5/0.75 mm OD/ID-World Precision Instruments, Sarasota, FL) that were pulled on a P-97 Flaming/Brown type micropipette puller (Sutter Instrument Co. ...
-
bioRxiv - Neuroscience 2020Quote: Somatic whole cell patch clamp recordings of visually identified CA1 principal cells were performed after 16-23 DIV with microelectrodes (3-8 MΩ) prepared from borosilicate glass capillaries (1B150F-4 World Precision Instruments) using a Sutter P-1000 puller ...
-
bioRxiv - Neuroscience 2020Quote: ... The administration speed was held constant at 800 nL/min by an injection pump (World Precision Instruments, Inc., UMP 3-4, USA), and the time interval between each injection path was 5 min (43) ...
-
bioRxiv - Neuroscience 2024Quote: ... two circular glass coverslips (one of 3 mm diameter and one of 4 mm) were affixed with a clear silicone elastomer (Kwik-Sil, World Precision Instruments). An extra layer of dental acrylic (C&B Metabond ...
-
bioRxiv - Neuroscience 2022Quote: ... glass pipettes (3-8 MΩ, 1B150F-3, World Precision Instruments) were pulled using a horizontal puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2024Quote: All recordings were performed at 31–33°C with electrodes (3–5 MΏ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with one of two intracellular solutions (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were obtained using low-resistance pipettes (2.2 - 5 MΩ) pulled from filamented borosilicate glass (World Precision Instruments, Cat #1B150F-4) with a flaming/brown micropipette puller (Sutter Instruments ...
-
bioRxiv - Molecular Biology 2024Quote: ... The electrical resistance of cell monolayers was measured on day 4 (before stimulation) and day 7 (after 3 days of stimulation) using an EVOM2 epithelial Volt/ Ohm meter (World Precision Instruments, FL, USA). The resistance of cell monolayers was corrected by subtracting the resistance of wells without cells and normalized by multiplying by the effective well surface area to provide transepithelial electrical resistance (TEER ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5-inch-long needle attached to a 5 µl Hamilton syringe was mounted to the stereotaxic frame and controlled using a Micro 4 Microsyringe Pump (World Precision Instruments) to infuse 0.5 µl AAV2/PHP.eB-hGfaABC1D-DIO-hTDP43-WT (1.2 × 1013 particles/µl) ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were plated onto either 13 mm 1.5 glass coverslips in 4-well plates or FluoroDish 35 mm dishes ready coated with poly-D-lysine (PDL) (World Precision Instruments). Glass coverslips were coated with 0.1 ug/ul PDL for 20 minutes and washed once with F12 ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were obtained using tungsten electrodes (TM31C40KT, 4-MΩ impedance at 1 kHz or TM31A50KT, 5-MΩ impedance at 1 kHz; World Precision Instruments Inc., Sarasota FL, USA). All recordings were pre-amplified in the DC mode ...
-
bioRxiv - Neuroscience 2022Quote: ... filamented glass capillaries (4”, 1.0 mm outer diameter; World Precision Instruments, 1B100F-4) were pulled using a Sutter P-97 Flaming/Brown type micropipette puller using a custom program with the following parameters ...
-
bioRxiv - Neuroscience 2024Quote: ... filamented glass capillaries (4”, 1.0 mm outer diameter; World Precision Instruments, 1B100F-4) were pulled using a Sutter P-97 Flaming/Brown type micropipette puller using a custom program with the following parameters ...