Labshake search
Citations for World Precision Instruments :
401 - 450 of 686 citations for 7 CHLORO 2H PYRIDO 2 3 B 1 4 OXAZIN 3 4H ONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2020Quote: Fly injections were carried out with microinjection needles produced from borosilicate glass capillaries (World Precision Instruments TW100-4) and a needle puller (Model PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... A micro-holding device62 was used to keep in the same coordinate the borosilicate capillary (1B150F-4, WPI) containing the LFP electrode and the optic fibre ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with high chloride internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Anterior body wall muscle cells were patched using 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA), which were pulled by micropipette puller P-1000 (Sutter) ...
-
bioRxiv - Neuroscience 2024Quote: ... Neurons were harvested using a thin wall glass capillary tube (4 inch, OD 1.0 MM, World Precision Instruments) into EBSS in a non-stick Eppendorf tube and kept on ice until dissociation.
-
bioRxiv - Neuroscience 2023Quote: ... and DVB soma were patched using 15-20 MΩ-resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Physiology 2022Quote: ... pulled from glass tubes (1.12 mm inner / 2 mm outer diameter, World Precision Instruments) and bent at 30 ° to allow near-parallel alignment of the fibres with the bottom of the experimental chamber ...
-
bioRxiv - Neuroscience 2023Quote: ... Bilateral infusions were achieved using a 35-gauge needle (World Precision Instruments NF35BV-2) and a 10 μL Hamilton Syringe (World Precision Instrument NANOFIL) ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Developmental Biology 2022Quote: ... It is connected to working solutions kept at 37 °C via a 4-channel peristaltic pump (WPI, PERIPRO-4LS). Lower GI tract was harvested and transferred to the organ bath with the Krebs buffer was flowing through ...
-
bioRxiv - Physiology 2019Quote: ... Hemolymph Na+ and K+ concentrations were measured using ion-selective borosilicate microelectrodes (TWI150-4, World Precision Instruments, Sarasota, USA). No interference from the FITC-dextran was found when measuring ions ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... and anterior muscle cells were patched using fire-polished 4−6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by HEKA EPC-9 patch clamp amplifier ...
-
bioRxiv - Neuroscience 2021Quote: ... DV -5.7) at a rate of 50 nl/minute using a microinjector-controlled syringe (micro-4, World Precision Instruments) and needle (Nanofil 33G beveled needle ...
-
bioRxiv - Neuroscience 2022Quote: ... D/V = −4) using 10 μl NanoFil syringes equipped with 33 gauge beveled NanoFil needles (World Precision Instruments, Inc.) at a volume of 0.7 μl and a rate of 0.1 μl per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled from filament-containing borosilicate glass capillaries (TW150F-4; World Precision Instruments Inc., Sarasota, FL, USA) using a Flaming/Brown Micropipette Puller (Model P-97 ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal extracellular recordings from the axons of the antennal nerve were made with glass microelectrodes (1B100F–4, WPI Inc.) filled with 0.15 M sodium chloride and inserted at the scape-pedicel joint ...
-
bioRxiv - Cell Biology 2024Quote: ... Resistance measurements were performed 4 days later in triplicate using an EVOM Epithelial Volt/ohm meter (World Precision Instruments). The values represent the average of three replicates minus the background resistance ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp recordings were performed with pipettes pulled (Sutter P-97) using borosilicate capillary tubes (WPI Cat # 1B150F-4) with open tip resistances of 20 +/- 3 MΩ filled with internal solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... +2.5 mm L/M and −3.0 mm D/V using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4). Glass micropipettes were mounted to the stereotaxic frame via specialized connectors and attached ...
-
bioRxiv - Neuroscience 2019Quote: ... pH 7.4) was infused over 2 min using a micro-injection system (World Precision Instruments). The needle was left in place for an additional 8 min after the injection ...
-
bioRxiv - Neuroscience 2020Quote: ... driven by a digital Micro2T controller (Model UMP3T-2; World Precision Instruments, Sarasota, FL, USA). After each injection ...
-
bioRxiv - Neuroscience 2019Quote: ... Whole-cell voltage-clamp recordings were obtained using borosilicate glass pipettes (2-5 MΩ; WPI) filled with intracellular solution containing the following (in mM) ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Anterior chambers were cannulated with 33-gauge beveled needles (NanoFil, NF33BV-2, World Precision Instruments) attached to micro-manipulators and equilibrated for 30 minutes at 9 mmHg ...
-
bioRxiv - Cancer Biology 2023Quote: ... which was experimentally validated using a set Ca2+ calibration buffers (World Precision Instruments, Calbuf-2). Rates of Ca2+ uptake were determined by fitting a single exponential from the initial peak after Ca2+ addition (T = 400 sec ...
-
bioRxiv - Microbiology 2023Quote: ... and 14 Trans-epithelial electrical resistance (TEER) was measured (EVOM-2 voltohmmeter, World Precision Instruments) 10 min after medium change ...
-
bioRxiv - Neuroscience 2023Quote: Eyes were initially punctured with a beveled needle (NF36BV-2, NanoFil Needles, World Precision Instruments) in the pars plana site that is posterior from the limbus of the eye [41 ...
-
bioRxiv - Neuroscience 2024Quote: ... The filling needle was replaced with a 35-gauge needle (World Precision Instruments, #NF35BV-2), and the syringe was secured to a micromanipulator (Model Kite-L ...
-
bioRxiv - Neuroscience 2021Quote: ... of 7 μm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2 mm O.D., 0.68 mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... Recording pipettes were pulled on a PP-830 vertical puller (Narishige) from borosilicate glass pipettes (1B150F-4, World Precision Instruments). Patch pipettes were pulled to resistances of 5-7 MΩ for hair cells ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were pulled from borosilicate glass capillaries (1.0 mm outside diameter, 0.58 mm inside diameter, 1B100F-4, World Precision Instruments) using a P-1000 puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2020Quote: Pipettes for OGB injections were pulled from borosilicate glass capillaries (1B150F-4, outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments) using a micropipette puller (P-97 ...
-
bioRxiv - Neuroscience 2019Quote: ... DiI crystals were manually placed just under the tissue surface using a pulled capillary glass (World Precision Instruments, 1B120F-4) using a dissecting microscope ...
-
bioRxiv - Cancer Biology 2022Quote: ... Borosilicate glass capillaries with a length of 4 inches and an OD of 1.0 mm (World Precision Instruments, FL, USA) were used for microinjection ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... of 7[µm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2[mm O.D., 0.68[mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... was used to create a micropipette (tip diameter 30-50 µm) from a micro glass tube (1.0-mm diameter; TW100F-4; WPI, USA). The pulled micropipette was then beveled using a micro grinder (EG-402 ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained using patch pipettes pulled from borosilicate glass capillaries (1B120F-4, World Precision Instruments). Pipette tip resistances were ∼4-10 MΩ for amacrine cell recordings in the ganglion cell layer ...
-
bioRxiv - Molecular Biology 2024Quote: ... 1 mm (WPI). The collected brain samples were stored in individual tubes at -20 °C until further analysis.
-
bioRxiv - Neuroscience 2022Quote: ... Injections were performed with a blunt 33-gauge stainless steel needle (NF33BL-2, World Precision Instruments) and a 10 μL microinjection syringe (Nanofil ...
-
bioRxiv - Neuroscience 2023Quote: ... Injections were performed with a blunt 33-gauge stainless steel needle (World Precision Instruments NF33BL-2) and a 10 µL microinjection syringe (World Precision Instruments NanoFil) ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral construct were administered in 4 injections within GPe using a UMP3 microsyringe pump injector (World Precision Instruments, Sarasota, FL, USA) with 100µl Hamilton syringe ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Neuroscience 2022Quote: Single-unit recordings of Purkinje neurons and cerebellar nuclei neurons were performed using borosilicate glass electrodes (1B100F-4, World Precision Instruments) with 1-to 2-μm tips ...
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 0.5 and 4 MΩ using a MF-200 microforge (World Precision Instruments). 90% series resistance (Rs ...
-
bioRxiv - Neuroscience 2024Quote: ... dorsoventral from the brain surface [DV] 1.9 mm) at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For the optogenetic silencing experiments (Figure 1H–N) ...