Labshake search
Citations for World Precision Instruments :
401 - 450 of 611 citations for 1 6 Chloropyridazin 3 yl piperidine 4 carboxamide since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... and Long Pulse Photostimulation (LPP; 4-10 s) waveforms were delivered under the command of a pulse generator (Pulsemaster A300 Generator; WPI) connected to the laser power supply ...
-
bioRxiv - Molecular Biology 2024Quote: ... 1 mm (WPI). The collected brain samples were stored in individual tubes at -20 °C until further analysis.
-
bioRxiv - Bioengineering 2022Quote: ... The needle was allowed to sit in place for approximately 5 min and 3-5 μL of viral vector was injected using a microsyringe pump (World Precision Instruments, UMP3) and pump controller (World Precision Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral Injections were unilaterally or bilaterally delivered using a syringe (65458-01, Hamilton, USA) controlled by an ultra-micropump (UMP-3, World Precision Instruments, USA) at a rate of 0.1 µl/min (total volume of 0.6 µl for slice imaging and 0.4 µl for fiber photometry) ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the cells were injected at the position 2 mm to the right lateral bregma and 3 mm deep with a flow of 0.2 μL/min utilizing a 10 μL precision micro syringe (World Precision Instruments, Florida, USA) with a 34-gauge needle ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral construct were administered in 4 injections within GPe using a UMP3 microsyringe pump injector (World Precision Instruments, Sarasota, FL, USA) with 100µl Hamilton syringe ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Neuroscience 2022Quote: Single-unit recordings of Purkinje neurons and cerebellar nuclei neurons were performed using borosilicate glass electrodes (1B100F-4, World Precision Instruments) with 1-to 2-μm tips ...
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 0.5 and 4 MΩ using a MF-200 microforge (World Precision Instruments). 90% series resistance (Rs ...
-
bioRxiv - Neuroscience 2024Quote: ... A total of 400 nl of AAV was injected at a rate of 80 nl/min and a depth of 0.6 mm into each of 4 injection sites with a microinjector (WPI, Nanoliter 2010) using the following coordinates (AP/ML ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were obtained using low-resistance pipettes (2.2 - 5 MΩ) pulled from filamented borosilicate glass (World Precision Instruments, Cat #1B150F-4) with a flaming/brown micropipette puller (Sutter Instruments ...
-
Clemizole and Trazodone are Effective Antiseizure Treatments in a Zebrafish Model of STXBP1 DisorderbioRxiv - Neuroscience 2022Quote: ... gap-free local field potential recordings (LFP; 60 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3) filled with 2 mM NaCl internal solution (~1 μm tip diameter ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole cell voltage and current-clamp recordings were performed at 32–34 °C with electrodes (3–5MΩ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with intracellular solution of the following composition (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... gap-free local field potential recordings (LFP; 15 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3); ~ 1 μm tip diameter ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were subject to nano-electrospray ionization (nESI) in positive ion mode (at ∼2 kV) with a pulled nanospray tip (World Precision Instruments 1B100-3) prepared as detailed in (48) ...
-
bioRxiv - Bioengineering 2021Quote: ... New Jersey) and custom 3D-printed components was assembled around the animal to support a 3-axis micromanipulator (502600, World Precision Instruments, Sarasota, FL) and linear actuator (M-235.5DD ...
-
bioRxiv - Neuroscience 2023Quote: ... A circular piece of the skull (3 mm in diameter) centered over the injection was carefully cut out using a sharp drill (Ideal micro drill, World Precision Instruments, Berlin, Germany). The dura was removed with forceps and mild vacuum suction was used to slowly remove the cortex within the craniotomy ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... at least 3 days before the day of injection and the craniotomies were covered with silicone elastomer (Kwik-Cast, World Precision Instruments, FL, USA). Before injection ...
-
bioRxiv - Neuroscience 2024Quote: ... square craniotomy (1-1-5 mm diameter) was made and covered with a coverslip (World Precision Instruments, coverslip No. 1) fitting the size of the bone removed ...
-
bioRxiv - Neuroscience 2021Quote: ... 200 nl of 1:1 mixture of AAV5 CAG-FLEx-TCb and AAV8 CAG-FLEx-RG was injected into the PVH at a speed of 50 nl/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For local circuit mapping (Fig ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
Prelimbic proBDNF facilitates memory destabilization by regulation of neuronal function in juvenilesbioRxiv - Neuroscience 2022Quote: ... which was arrayed into a 4×8 matrix using 25-μm-diameter tungsten wires (California Fine Wires) in a 35-gauge silica tube (World Precision Instruments). A cannula was attached to a silica tube ...
-
bioRxiv - Neuroscience 2023Quote: ... A total of 250 nL AAV was dispensed at each cortical layer through a glass-capillary-attached Hamilton syringe at a rate of 40 nL/min using a UltraMicroPump-4 system (World Precision Instruments). To image UDP in hippocampus ...
-
The CB1 receptor interacts with cereblon and drives cereblon deficiency-associated memory shortfallsbioRxiv - Neuroscience 2023Quote: Adult mice (2 months-old) were anaesthetized with isoflurane (4%) and placed into a stereotaxic apparatus (World Precision Instruments, Sarasota, FL, US). Adeno-associated viral particles were injected with a Hamilton microsyringe (Sigma-Aldrich #HAM7635-01 ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5-inch-long needle attached to a 5 µl Hamilton syringe was mounted to the stereotaxic frame and controlled using a Micro 4 Microsyringe Pump (World Precision Instruments) to infuse 0.5 µl AAV2/PHP.eB-hGfaABC1D-DIO-hTDP43-WT (1.2 × 1013 particles/µl) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes for patch clamping were prepared freshly on the day of electrophysiology experiments from filamented glass capillaries (1B150F-4, World Precision Instruments) using a horizontal pipette puller (P1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV8 hSyn-DIO-hM3Dq-mCherry or AAV5 hSyn-DIO-mCherry was bilaterally injected into the PVH at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). The coordinates for injection into the supraoptic nucleus were as follows ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV serotype 9 OTp-mCherry was bilaterally injected into the PVH and the supraoptic nucleus at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments).
-
Dietary potassium and cold acclimation additively increase cold tolerance in Drosophila melanogasterbioRxiv - Physiology 2024Quote: ... The ion-selective microelectrodes used to measure hemolymph [K+] were fashioned from glass capillaries (TW150-4, World Precision Instruments, Sarasota, FL, USA) and pulled to a ∼ 1-3 mm tip on a Flaming-Brown micropipette puller (P-1000 ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were plated onto either 13 mm 1.5 glass coverslips in 4-well plates or FluoroDish 35 mm dishes ready coated with poly-D-lysine (PDL) (World Precision Instruments). Glass coverslips were coated with 0.1 ug/ul PDL for 20 minutes and washed once with F12 ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Physiology 2024Quote: ... using glass pulled microelectrodes filled with 3 M KCl (pipette resistance: 30–60 MΩ) connected to a DUO 773 electrometer (World Precision Instruments, Inc., FL, USA). For smooth muscle and endothelium recordings ...
-
bioRxiv - Biophysics 2020Quote: ... The signal from the force transducer was amplified using Transbridge TBM4M and digitized using Lab-Trax-4 data acquisition hardware (WPI, Sarasota, FL, USA). Three phases could be distinguished on force curves recorded using LabScribe v3 (iWorks ...
-
bioRxiv - Microbiology 2020Quote: The permeability of the differentiated epithelial layer (after 4 weeks of differentiation) was determined by measuring the TEER using an epithelial volt-ohm meter (EVOM2, World Precision Instruments, Inc.). The EVOM2 was calibrated according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus was injected via a pulled needle of a borosilicate glass capillary (ID: 0.68mm, OD: 1.2mm; Kwik-fill, World Precision Instruments Inc., # 1B150F-4) that was angled at 50° to the slice using a stereotactic micromanipulator (SM-11 ...
-
bioRxiv - Neuroscience 2024Quote: ... Local field-potential (LFP) activity was recorded using a patch pipette prepared from thin-borosilicate glass (1.5mmOD, 0.84mmID, World Precision Instruments, cat.no. 1B150F-4) pooled and fire-polished on a Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2024Quote: Glass capillary tubes with an inner diameter about 0.2 mm were prepared from thin wall glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL), using puller (PC-100 ...
-
bioRxiv - Neuroscience 2020Quote: ... were applied with a glass pipette (2-3 μm diameter) positioned 20 to 30 μm away from the soma and connected to a picospritzer (World Precision Instruments, adjusted to ~2 psi). All electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2022Quote: ... A standard micropipette injection protocol was used to make all injections into the brain or spinal cord using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2020Quote: MC3T3-E1 Subclone 4 (ATCC® CRL-2593™) preosteoblastic cells were cultured on duplicate samples of tissue-cultured polystyrene (Fluorodish, World Precision Instruments) and commercially available argon-treated BC (CoArBC) ...
-
bioRxiv - Biophysics 2023Quote: ... A standard micropipette injection protocol was used to make all injections into the brain using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2024Quote: Molds for the device assembly were fabricated using PDMS and biopsy punches of 4 mm and 7 mm diameters (World Precision Instruments, Sarasota, FL). A large well was made in the PDMS with the 7 mm punch ...
-
bioRxiv - Neuroscience 2024Quote: ... A Hamilton syringe (Hamilton 7635-01) was filled with either PBS or C9-ASO at 50 ng/μL and attached to a microinjection pump (World Precision Instruments Micro 4) on a stereotactic arm ...
-
bioRxiv - Neuroscience 2023Quote: ... and 26-gauge needle (Hamilton) at a flow rate of 100 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Genetics 2023Quote: ... 0.5nl of the mixtures were directly injected into the yolk of freshly layed zygotes using a glass capillary needle [TW120-4) (Kwik-Fil, World Precision Instruments, Inc., Hertfordshire, UK)] with the help of a pedal controlled microinjector (PV820 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato, USA or 1B150F-4, World Precision Instruments, Sarasota, USA) in a horizontal pipette puller (P-1000 Micropipette puller ...