Labshake search
Citations for World Precision Instruments :
301 - 350 of 535 citations for Methyl 3 2 morpholin 4 ylethoxy benzoate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2023Quote: ... The samples were electrosprayed from gold-coated borosilicate glass capillaries Kwik-Fil 1B120F-4 (World Precision Instruments) prepared in-house essentially as described before (49 ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipettes with 4.5-6.5 MΩ tip resistance were prepared from borosilicate glass capillaries (TW150F-4, WPI) using micropipette pullers (HEKA PIP 6 and MDI PMP102) ...
-
bioRxiv - Cell Biology 2023Quote: ... Microinjection was performed using borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA). 200-250 HeLa cells transfected with si-NC or si-METTL3 at a concentration of 25 nM were injected directly into the middle of the yolk sac of the larva ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by AAV injections using a micro-syringe connected to a micropump (UltraMicroPump 4, WPI surgical instruments), which was lowered into the brain until it reached the DV coordinates (see below for details) ...
-
bioRxiv - Neuroscience 2024Quote: ... and an outer diameter of 1 mm (Sutter BF100-50-10 or World Precision Instruments 1B100F-4). Patch pipettes were pulled with a Narishige PC10 electrode puller from borosilicate glass capillaries without filament ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes were pulled from 1.5 mm borosilicate glass capillaries (World Precision Instruments; 4-8 MW resistance). Pipettes were filled with K-gluconate intracellular solution for intrinsic experiments ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes with resistance between 1.5-4 MΩ were prepared using borosilicate glass capillaries (World Precision Instruments, Inc ...
-
bioRxiv - Neuroscience 2024Quote: ... Affixed to the vials was a rubber stopper with one glass pipet (World Precision Instruments, #1B150F-4), initially empty ...
-
bioRxiv - Biochemistry 2024Quote: ... Samples were loaded into in-house prepared golden-coated borosilicate glass capillaries (1B120F-4, World Precision Instruments) and electrosprayed into a Waters Synapt G2Si mass spectrometer ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording glass electrode (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) was pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 20-30 nl/minute into the parenchyma ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were performed with low resistance (1–3 MΩ) glass pipettes (ID: 0.68 mm, OD: 1.2 mm, WPI, Sarasota, FL) filled with aCSF under current-clamp mode with I=0 configuration ...
-
bioRxiv - Neuroscience 2023Quote: ... 30–120 nl of virus were injected at a rate of 3 nl/s at two depths (0.1 mm and 0.2 mm ventral/below pia) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Neuroscience 2024Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 30-40 nl/min into the parenchyma ...
-
bioRxiv - Physiology 2022Quote: ... pulled from glass tubes (1.12 mm inner / 2 mm outer diameter, World Precision Instruments) and bent at 30 ° to allow near-parallel alignment of the fibres with the bottom of the experimental chamber ...
-
bioRxiv - Neuroscience 2023Quote: ... Bilateral infusions were achieved using a 35-gauge needle (World Precision Instruments NF35BV-2) and a 10 μL Hamilton Syringe (World Precision Instrument NANOFIL) ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording pipettes (resistance of 4-7 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with internal solution (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette consisted of 5 barrels in an H configuration (World Precision Instruments, catalogue no. 5B120F-4) with the tip broken to a diameter of 30–40 μm [37] ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Microinjection needles were prepared from glass capillary tubes (0.58 mm inner diameter; World Precision Instruments, FL; 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Microbiology 2020Quote: Fly injections were carried out with microinjection needles produced from borosilicate glass capillaries (World Precision Instruments TW100-4) and a needle puller (Model PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... A micro-holding device62 was used to keep in the same coordinate the borosilicate capillary (1B150F-4, WPI) containing the LFP electrode and the optic fibre ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with high chloride internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... and DVB soma were patched using 15-20 MΩ-resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Neuroscience 2023Quote: ... Anterior body wall muscle cells were patched using 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA), which were pulled by micropipette puller P-1000 (Sutter) ...
-
bioRxiv - Neuroscience 2024Quote: Extracellular stimulation of layer 4 was performed with a constant current isolator (World Precision Instruments A365 Stimulus Isolator) to deliver current through a low resistance (∼750 kΩ ...
-
bioRxiv - Neuroscience 2024Quote: ... For these observations we used glass microelectrodes fashioned from filamented borosilicate glass (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2024Quote: ... For these observations we used glass microelectrodes fashioned from filamented borosilicate glass (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Genetics 2020Quote: ... Glass needles for zebrafish eggs injections were prepared from glass capillary tubes with filament (ø1 mm × 90 mm) (WPI #1B100F-3) using a NARISHIGE dual-stage micropipette puller PC-10 machine ...
-
bioRxiv - Biophysics 2020Quote: ... were collected by centrifugation for 3 min at 180 RCF and seeded onto glass bottom dishes (fluorodish; #FD35100, WPI, FL, USA) in CO2-independent medium (#18045-054 ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2022Quote: ... The tip of the pipette was cut to an opening diameter of ∼3 μm and bent to ∼40° using a microforge (WPI, DMF1000). Tethers were pulled with a 4 µm diameter polystyrene bead (Spherotech #DIGP-40-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... We sealed the craniotomy with silicone gel (Dow DOWSIL 3-4680, sometimes called “artificial dura”) and a silicone sealant (WPI KwikCast). We also implanted a stainless steel pin elsewhere on the dorsal surface of the skull ...
-
bioRxiv - Developmental Biology 2024Quote: Erythrocytes were isolated from 3-dpf zebrafish embryos (wild-type and miR-144Δ/Δ) by dissecting their tail using sapphire blade (WPI) and collecting cells in the bleeding buffer (1X PBS containing 2% PBS and 5 mM EDTA) ...
-
bioRxiv - Neuroscience 2024Quote: ... Reference glass electrode and recording glass electrode were created by processing Standard Glass Capillaries (Cat # IB150F-3, World Precision Instruments, USA) with glass puller ...
-
bioRxiv - Neuroscience 2024Quote: ... We used 3−5 MΩ glass patch pipettes (capillary tubing with 1.5/0.75 mm OD/ID-World Precision Instruments, Sarasota, FL) that were pulled on a P-97 Flaming/Brown type micropipette puller (Sutter Instrument Co. ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Developmental Biology 2022Quote: ... It is connected to working solutions kept at 37 °C via a 4-channel peristaltic pump (WPI, PERIPRO-4LS). Lower GI tract was harvested and transferred to the organ bath with the Krebs buffer was flowing through ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... The larvae (4-7 dpf) were paralyzed by 0.1% α-bungarotoxin and embedded in a 10 mm FluoroDish (WPI) with low-melting point agarose (Camplex SeaPlaque Agarose ...
-
bioRxiv - Neuroscience 2020Quote: ... and anterior muscle cells were patched using fire-polished 4−6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by HEKA EPC-9 patch clamp amplifier ...
-
bioRxiv - Neuroscience 2021Quote: ... DV -5.7) at a rate of 50 nl/minute using a microinjector-controlled syringe (micro-4, World Precision Instruments) and needle (Nanofil 33G beveled needle ...
-
bioRxiv - Neuroscience 2022Quote: ... D/V = −4) using 10 μl NanoFil syringes equipped with 33 gauge beveled NanoFil needles (World Precision Instruments, Inc.) at a volume of 0.7 μl and a rate of 0.1 μl per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled from filament-containing borosilicate glass capillaries (TW150F-4; World Precision Instruments Inc., Sarasota, FL, USA) using a Flaming/Brown Micropipette Puller (Model P-97 ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Cell Biology 2024Quote: ... Resistance measurements were performed 4 days later in triplicate using an EVOM Epithelial Volt/ohm meter (World Precision Instruments). The values represent the average of three replicates minus the background resistance ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal extracellular recordings from the axons of the antennal nerve were made with glass microelectrodes (1B100F–4, WPI Inc.) filled with 0.15 M sodium chloride and inserted at the scape-pedicel joint ...
-
bioRxiv - Physiology 2023Quote: ... The glass microelectrodes were fashioned from 1 mm borosilicate glass capillaries (1B100F-4, World Precision Instruments, Sarasota, FL, USA) pulled to a tip resistance of 5-7 MΩ in a Flaming-Brown P-1000 micropipette puller ...