Labshake search
Citations for World Precision Instruments :
301 - 350 of 376 citations for DOLICHOL FROM BOVINE HEART since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2020Quote: The nanopipettes with ∼60 nm diameters were fabricated from quartz glass capillaries of 0.5 mm inner diameter (QF100-50-7.5, World precision Instruments, UK) using a Sutter instrument model P-2000 laser puller ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Biophysics 2022Quote: ... Subsequently the agarose film was further rehydrated by fusing a 2.3 nl volume of buffer to it from a nanolitre piezo-injector (World Precision Instruments). Once the imaging conditions had been optimized ...
-
bioRxiv - Neuroscience 2020Quote: ... VP neurons were visualized using an Olympus BX51WI microscope and recorded from using glass pipettes (1.3-2 MΩ, World Precision Instruments) filled with internal solution (in mM ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Neuroscience 2022Quote: ... Stimulation of excitatory fibers was performed with a stimulating electrode (bipolar concentric electrode from Phymep and stimulator A365, World Precision Instruments). Intracellular solution based on K-gluconate (containing in mM ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes were pulled from borosilicate glass (outer diameter 1.5 mm, inner diameter 1.12 mm, World Precision Instruments, Sarasota, FL, USA) to a tip resistance of 2-5 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass pipettes with a resistance of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Developmental Biology 2024Quote: Erythrocytes were isolated from 3-dpf zebrafish embryos (wild-type and miR-144Δ/Δ) by dissecting their tail using sapphire blade (WPI) and collecting cells in the bleeding buffer (1X PBS containing 2% PBS and 5 mM EDTA) ...
-
bioRxiv - Biochemistry 2024Quote: ... For the detection of H2S release from persulfidated compounds a selective H2S electrode of a Free Radical Analyzer (World Precision Instruments) was used ...
-
bioRxiv - Neuroscience 2023Quote: ... was infused into the CA1 region at a depth of 1.3 mm from the dura (rate: 50 nl/min) using a pulled glass micropipette and microinjection pump (World Precision Instruments). Three weeks after viral injection ...
-
bioRxiv - Neuroscience 2023Quote: ... Micropipettes were made from 1.5 mm OD/1.12 mm ID borosilicate glass with a filament (World Precision Instruments, Sarasota, FL, USA) and resistance was 2–4 MΩ ...
-
bioRxiv - Neuroscience 2024Quote: ... DNA was injected into the lateral ventricles via surgical needles pulled from glass thin-walled capillaries (World Precision Instruments, TW15-OF4). A triple-electrode configuration was used to apply 5 electrical pulses ...
-
bioRxiv - Neuroscience 2024Quote: ... and was fixed and insulated from surrounding tissue using the quick-setting silicone adhesive Kwik-Sil (World Precision Instruments, FL, USA). After separating the vagus nerve from the carotid artery ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were obtained using low-resistance pipettes (2.2 - 5 MΩ) pulled from filamented borosilicate glass (World Precision Instruments, Cat #1B150F-4) with a flaming/brown micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Stimulation of excitatory fibers was performed with a stimulating electrode (bipolar concentric electrode from Phymep and stimulator A365, World Precision Instruments) located in the fiber bundle between the cortex and the ventral striatum ...
-
bioRxiv - Neuroscience 2020Quote: Somatic whole cell patch clamp recordings of visually identified CA1 principal cells were performed after 16-23 DIV with microelectrodes (3-8 MΩ) prepared from borosilicate glass capillaries (1B150F-4 World Precision Instruments) using a Sutter P-1000 puller ...
-
bioRxiv - Biophysics 2022Quote: ... 20-50 μl of cell suspension from the bottom of the tube was transferred for imaging to a 35-mm glass-bottomed microscopy dish (FluoroDish, World Precision Instruments). Wave formation was most abundant 3-6 h after the initiation of development.
-
bioRxiv - Neuroscience 2021Quote: ... directly on the S1 site to protect the thinned skull from contamination and infection and sealed the exposed skull with a silicone elastomer (Kwik-Cast, World Precision Instruments).
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... the cells were approached with micropipettes of 1.2-3.3 MΩ resistance manufactured from 1.5 mm OD glass (World Precision Instruments, Sarasota, Florida, USA) on a microelectrode puller ...
-
bioRxiv - Neuroscience 2022Quote: In vivo intracellular recordings of cortical cells were performed in the primary visual cortex (area 1. 17) using sharp Glass electrodes pulled from 1.5-mm-thick borosilicate capillaries (World Precision Instruments Inc.). Electrodes were filled with a 2M potassium methyl sulfate (pH ranging from 7.2 to 7.4) ...
-
bioRxiv - Cell Biology 2022Quote: ... IVT reticulocyte lysate was backloaded into a needle pulled from a 1 mm glass capillary tube (TW 100F-4, World Precision Instruments) using a P-87 Micropipette Puller (Sutter Instrument) ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes were fabricated from GC150F-10 borosilicate glass capillaries as aforementioned and then fire-polished with a MF-200 microforge (World Precision Instruments) to obtain a tip resistance of 2–5 MΩ when filled with the recording solution (composition in mM ...
-
bioRxiv - Molecular Biology 2022Quote: ... Action potentials were caused by passing a 1 ms current pulse through platinum-iridium electrodes from an isolated current stimulator (World Precision Instruments). Neurons were perfused in saline-based Tyrode’s buffer consisting of 119 mM NaCl ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes were pulled from borosilicate glass capillaries with an inner filament (1.5 mm outer diameter; World Precision Instruments Inc., Sarasota, FL) on a pipette puller (P-97 ...
-
bioRxiv - Molecular Biology 2021Quote: Microinjection needles were prepared from thin wall borosilicate glass capillaries with filament (Outer diameter 1.0mm, inner diameter 0.75mm. World Precision Instruments, Sarasota, USA) on a micropipette puller (P-1000,Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Extracellular field potentials from de CA1 pyramidal neurons were recorded using a borosilicate glass micropipette (1–3 MΩ; RRID:SCR_008593; World Precision Instruments, Sarasota, US) filled with aCSF positioned on the slice surface in the stratum radiatum of CA1 and connected to the headstage of an extracellular recording amplifier (NeuroLog System ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings from GPe neurons were obtained using micropipettes (2–4MΩ) made from 1.5 mm OD/1.12 mm ID borosilicate glass with a filament (World Precision Instruments, Sarasota, FL) pulled with a P-97 puller (Sutter Instruments Novato ...
-
bioRxiv - Neuroscience 2023Quote: Nanopipettes were fabricated from quartz capillaries with filament (o.d. 1 mm, i.d. 0.5 mm, 10 cm length, World Precision Instruments QF100-50-10). The capillaries were transformed into nanopipettes using a laser puller (P2000 ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes for patch clamping were prepared freshly on the day of electrophysiology experiments from filamented glass capillaries (1B150F-4, World Precision Instruments) using a horizontal pipette puller (P1000 ...
-
bioRxiv - Bioengineering 2023Quote: ... DV –4.5 mm) using a microinjection apparatus (10 µL Hamilton syringe #80308, UMP-3 syringe pump, and Micro4 controller; all from World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... were recorded from the stratum radiatum (or stratum pyramidale region where indicated) region of CA1 using a borosilicate glass (WPI, Sarasota, Fl) microelectrode (pulled (Sutter ...
-
bioRxiv - Cell Biology 2023Quote: ... from day 1 to day 6 of subculture of BMEC onto Transwells® using an EVOM2 Voltohmmeter/STX2 electrodes (World Precision Instruments). The STX2 electrode was positioned within the well and the resistance (Ω ...
-
bioRxiv - Genetics 2022Quote: ... Each adult female was injected with 3 ul injection mix between the 4th and 5th abdominal sternites using a glass needle pulled from borosilicate glass capillary tubes (World Precision Instruments). Each injected female was paired with a male and kept individually in a Drosophila vial supplied with raw sunflower seeds ...
-
bioRxiv - Neuroscience 2023Quote: ... EOD commands were also recorded from the EMNs and sent to a window discriminator for time stamping (SYS-121, World Precision Instruments). At the end of the recording session ...
-
bioRxiv - Developmental Biology 2023Quote: ... One-cell stage fertilized eggs were aligned in a custom-made setup and microinjected into the cell using pressurized microinjector from World Precision Instruments. Injection volumes were optically adjusted to about 5% from the cell volume ...
-
bioRxiv - Neuroscience 2024Quote: ... A recording pipette with a resistance of 3–6 MΩ was pulled from a borosilicate glass capillary (World Precision Instruments, Sarasota, FL) using a micropipette puller (Model P-97 ...
-
bioRxiv - Neuroscience 2024Quote: ... we applied transparent Metabond dental acrylic directly on the S1 site to protect the thinned skull from contamination and infection and sealed the exposed skull with a silicone elastomer (Kwik-Cast, World Precision Instruments).
-
Dietary potassium and cold acclimation additively increase cold tolerance in Drosophila melanogasterbioRxiv - Physiology 2024Quote: ... The ion-selective microelectrodes used to measure hemolymph [K+] were fashioned from glass capillaries (TW150-4, World Precision Instruments, Sarasota, FL, USA) and pulled to a ∼ 1-3 mm tip on a Flaming-Brown micropipette puller (P-1000 ...
-
bioRxiv - Physiology 2024Quote: Micropipettes were pulled using a two-stage puller (Narishige, Tokyo, Japan) from filamented borosilicate glass capillaries (World Precision Instruments, Sarasota, FL USA). mAoEC were cultured on glass coverslips and transfected with wild-type or mutant MARCKS constructs ...
-
bioRxiv - Neuroscience 2024Quote: All recordings were performed at 31–33°C with electrodes (3–5 MΏ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with one of two intracellular solutions (in mM) ...
-
bioRxiv - Physiology 2024Quote: ... DV−4.2 from the skull) at a rate of 0.5ul per minute using a microinjection pump (World Precision Instruments, Inc., Florida, USA). After each injection ...
-
bioRxiv - Neuroscience 2024Quote: ... Glass electrodes had at tip resistance of 0.5-2.5 MΩ and were pulled from thin-walled glass capillary tubes (World Precision Instruments, Hertfordshire, UK) using a PC-10 puller (Narishige ...
-
bioRxiv - Biophysics 2020Quote: ... The signal from the force transducer was amplified using Transbridge TBM4M and digitized using Lab-Trax-4 data acquisition hardware (WPI, Sarasota, FL, USA). Three phases could be distinguished on force curves recorded using LabScribe v3 (iWorks ...
-
bioRxiv - Neuroscience 2020Quote: ... 3 mm and 2.7 mm dorsoventral from the skull surface using a microliter syringe (Hamilton, USA) controlled by a four-channel micro controller (SYS-Micro4, World Precision Instruments, USA). After the last injection step ...
-
bioRxiv - Systems Biology 2020Quote: ... A constant volume (0.1 L min−1) from the odor bottle headspace was injected into the carrier stream using a pneumatic pico-pump (WPI Inc., PV-820) during odor presentations ...
-
bioRxiv - Bioengineering 2022Quote: ... The flow modules were extracted from the mold and access ports were cored using a 1 mm biopsy punch (World Precision Instruments, USA).
-
bioRxiv - Cancer Biology 2023Quote: ... a custom-made EEG adapter with attached wires (2 recording channels, one reference, each made from Teflon-coated silver (WPI, Sarasota, FL, USA) wire with ∼0.5mm tips exposed ...
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
bioRxiv - Neuroscience 2024Quote: ... Local field-potential (LFP) activity was recorded using a patch pipette prepared from thin-borosilicate glass (1.5mmOD, 0.84mmID, World Precision Instruments, cat.no. 1B150F-4) pooled and fire-polished on a Flaming/Brown micropipette puller (Sutter Instrument ...