Labshake search
Citations for World Precision Instruments :
3151 - 3200 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Surface of the corpus callosum was protected with QuickSil (WPI) then the cannula with the window was implanted and fixed to the heaplate of the animal.
-
bioRxiv - Cell Biology 2020Quote: WT fibroblasts were seeded in 35 mm dishes (WPI, FD3510-10), grown to confluence and differentially entrained with temperature cycles ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2020Quote: ... Transverse and superior articular processes of the vertebra were removed using microdissection scissors and OmniDrill 35 (WPI). To obtain a clear image of the sensory neuron cell bodies in the ipsilateral dorsal root ganglion (DRG) ...
-
bioRxiv - Biophysics 2020Quote: Pipettes were pulled from borosilicate glass capillaries (TW150F-3; World Precision Instruments, Sarasota, FL, USA) and polished with a microforge (MF-900 ...
-
bioRxiv - Biophysics 2020Quote: ... capillaries were handmade by pulling borosilicate glass tubes (inner diameter 0.68 mm, outer diameter 1.2 mm with filament, World Precision Instruments, Sarasota, FL, USA) using a two-step program in a micropipette puller (Sutter Instruments ...
-
Modified N-linked glycosylation status predicts trafficking defective human Piezo1 channel mutationsbioRxiv - Biophysics 2020Quote: ... Negative pressure was applied to patch pipettes using a High Speed Pressure Clamp-1 (ALA Scientific Instruments, Farmingdale, NY, USA) and recorded in millimetres of mercury (mmHg) using a piezoelectric pressure transducer (WPI, Sarasota, FL, USA). Borosilicate glass pipettes (Sigma-Aldrich ...
-
bioRxiv - Biophysics 2020Quote: ... The resulting 1D channels of 5 μm height and 5 μm width were sealed in 35-mm glass bottomed cell culture dishes (World Precision Instruments, Sarasota, FL, USA) using plasma surface activation ...
-
bioRxiv - Biophysics 2020Quote: ... were pulled in-house from borosilicate capillaries (1.2 mm outer diameter, 0.68 mm inner diameter, with filament, World Precision Instruments) with a micropipette puller (P-1000 ...
-
bioRxiv - Biophysics 2020Quote: ... The pipette electrodes were pulled from capillary tubing (World Precision Instruments) on pipette puller (Sutter Instruments ...
-
bioRxiv - Biophysics 2020Quote: ... Recording pipettes were fabricated from the TW150-6 borosilicate glass capillaries (World Precision Instruments Inc.) using the pp830 vertical puller (Narishige International) ...
-
bioRxiv - Biophysics 2020Quote: ... After punching a fluid port through the 5 mm thick Sylgard using 0.75 mm diameter biopsy punches (World Precision Instruments) the PDMS chip was bonded onto glass substrates using an 0.3 mbar ...
-
bioRxiv - Biophysics 2020Quote: The nanopipettes with ∼60 nm diameters were fabricated from quartz glass capillaries of 0.5 mm inner diameter (QF100-50-7.5, World precision Instruments, UK) using a Sutter instrument model P-2000 laser puller ...
-
bioRxiv - Biophysics 2020Quote: ... Using a syringe pump (AL-2000, World Precision Instruments) CO2-charged medium is pumped through the flow chamber at a flow rate of 500 μl/min for < 1 min to flush out non-attached and possible dead cells ...
-
bioRxiv - Cell Biology 2020Quote: ... 50 mm FluoroDish tissue culture dishes (World Precision Instruments, Inc., #FD5040-100) were coated with 1:10 PDMS using a spin coater ...
-
bioRxiv - Cell Biology 2020Quote: ... the cells were re-plated onto a cover-glass bottom dish (FluoroDish, WPI, #FD35-100) at 2 – 4 days post-transfection at an appropriate density and imaged after another 2 – 3 days ...
-
bioRxiv - Cell Biology 2020Quote: ... A365 stimulus isolator (WPI, Sarasota, FL, USA) was used for electrical stimulation ...
-
bioRxiv - Cell Biology 2020Quote: ... on to 1×105 adhered U–2–OS or U–2–OS Flp-In T-Rex cells in 2 mL media in a 3.5 cm glass bottom dish (FD35–100, WPI). 8 hr following transfection ...
-
bioRxiv - Neuroscience 2020Quote: ... were dissected into fine multiunit branches and a single branch was placed within a sealed glass pipette containing a microelectrode (WPI) attached to a Neurolog headstage (NL100AK ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording electrodes (thin-wall glass, WPI Instruments) were made using a PC-10 puller (Narishige International ...
-
bioRxiv - Neuroscience 2020Quote: ... radial cuts around the limbus of the eye were made using spring scissors (WPI, 501235) to remove the anterior segment of the eye (cornea and lens) ...
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2020Quote: ... KCl was puffed onto dorsolateral striatum for 10 seconds at 9 µl/s using a syringe pump (World Precision Instruments) and recordings were in ACSF (unless mentioned otherwise) ...
-
bioRxiv - Neuroscience 2020Quote: ... The AAVs and CTB were stereotaxically injected with a glass pipette connected to a Nano-liter Injector 201 (World Precision Instruments, Inc.) at a slow flow rate of 0.15 μl / min to avoid potential damage to local brain tissue ...
-
bioRxiv - Neuroscience 2020Quote: ... Neurons were stimulated by field stimulation with a custom-built platinum wire electrode with a stimulus isolator (A385, World Precision Instruments). Trains of 1 ...
-
bioRxiv - Neuroscience 2020Quote: ... and the dura was protected by a layer of Kwik-Sil (WPI). A custom 3D printed recording chamber and interlocking lid (NeuroNexus ...
-
bioRxiv - Neuroscience 2020Quote: ... Kwik-Sil (WPI) was added on top of the lens and allowed to cure for 10 minutes ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were pulled from thin-walled borosilicate glass (1.5/1.12 mm OD/ID; WPI, Sarasota, FL) to 5-to 10-MΩ resistances when filled with an internal solution containing (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... The exposed brain was then covered with a humid gelatinous hemostatic sponge (Surgispon) and silicone sealant (KwikCast, World Precision Instruments) until the experiment was performed (1-2 h after recovery).
-
bioRxiv - Neuroscience 2020Quote: ... A drop of silicone sealant (Kwik-Sil, WPI) was placed in the hole ...
-
bioRxiv - Neuroscience 2020Quote: ... 1.8M NaCl solution was then injected via glass micropipette (TIP01TW1F, WPI) at a flow rate of 309μL/min for 10 seconds in one eye while the fellow eye served as the contralateral control ...
-
bioRxiv - Neuroscience 2020Quote: ... mounted on a syringe pump controlled by a microcontroller (UMP3 + micro4, WPI). After trepanation of the skull ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were made from capillary glass (1 mm outer diameter, 0.58 mm inner diameter; WPI) with a horizontal puller (Sutter Instrument P1000 ...
-
bioRxiv - Microbiology 2020Quote: Cells were seeded at 2.5 x 105 cells/dish in a glass bottom FuoroDish (World Precision Instruments) on the day prior to the experiment ...
-
bioRxiv - Microbiology 2020Quote: ... HeLa cells were plated either in a glass bottom FluoroDish (World Precision Instruments) or in a glass-bottom Cellview Cell Culture Dish with 4 compartments (Greiner Bio-One) ...
-
bioRxiv - Neuroscience 2020Quote: ... Lentivirus was delivered at a rate of 500 nL/minute using an injection pump (UMC4, World Precision Instruments, Inc., Sarasota, FL). After completion of delivery ...
-
bioRxiv - Neuroscience 2020Quote: ... Whisker stimulation used puffs of air deflecting all whiskers and whisker pad (World Precision Instruments PV830 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2020Quote: ... patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a PC-10 Narishige puller and filled with a pipette solution containing the following (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... connected to a constant-current isolator (DLS100, WPI, Sarasota, Florida). These stimulation parameters were based on previous experiments [20] ...
-
bioRxiv - Neuroscience 2020Quote: ... Body temperature was controlled and maintained at 37°C by means of a heating pad (ATC1000, World Precision Instruments, Sarasota, Florida). Rats were mounted on a stereotaxic apparatus (Stoelting Co ...
-
bioRxiv - Neuroscience 2020Quote: ... HFS (100 Hz, 60 μs, 100 μA, bipolar, monophasic square-wave pulses) was applied with a stimulator (DS8000, World Precision Instruments, Sarasota, Florida) connected to a constant-current isolator (DLS100 ...
-
bioRxiv - Developmental Biology 2020Quote: ... Limited reuse biopsy punches (World Precision Instruments – #504528 [0.5mm] ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch-clamp recording pipettes were fabricated from 1 mm inner diameter borosilicate glass capillaries (World Precision Instruments, item# 1B100F-4). Pipettes were pulled with a multistep horizontal puller (P-1000 ...
-
bioRxiv - Microbiology 2020Quote: The permeability of the differentiated epithelial layer (after 4 weeks of differentiation) was determined by measuring the TEER using an epithelial volt-ohm meter (EVOM2, World Precision Instruments, Inc.). The EVOM2 was calibrated according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2020Quote: ... cells were plated on glass-bottom 35mm dishes (Fluorodish FD35-100 WPI) in growth media ...
-
bioRxiv - Neuroscience 2020Quote: ... at a rate of 0.2 μL/min with a glass micropipette connected to a Hamilton syringe controlled by stereotaxic syringe holder (SYS-Micro4, WPI, Sarasota, FL, USA). The needle was removed 10 min later ...
-
bioRxiv - Neuroscience 2020Quote: ... Virus was infused at a rate of 25 nl/min with a micropump and controller (World Precision Instruments, UMP3 pump and Micro4 controller) for a total of 250 nl (DMH ...
-
bioRxiv - Neuroscience 2020Quote: ... Kwik-Sil silicone adhesive (World Precision Instruments) was used to seal the craniotomy between recording days ...
-
bioRxiv - Neuroscience 2020Quote: ... A boron-doped glass capillary (PG10150, World Precision Instruments) was pulled with a horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes were pulled from borosilicate glass (World Precision Instruments) to a resistance of 3–5 MΩ using a vertical pipette puller (Narishige ...