Labshake search
Citations for World Precision Instruments :
251 - 300 of 526 citations for 6H Furo 2 3 g 3 benzazepine 2 ethyl 7 8 9 10 tetrahydro 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Neuroscience 2022Quote: ... The injection needle (34-g, beveled, WPI) was left in place for 3 and 5 min after the first and second injections (100-nl/min ...
-
bioRxiv - Neuroscience 2021Quote: The stimulation parameters were controlled by a pulse generator (Master 9; World Precision Instruments, Sarasota, FL, USA). For light stimulation ...
-
bioRxiv - Neuroscience 2020Quote: ... The LED driver was controlled by a pulse generator (Master 9; World Precision Instruments, Sarasota, FL, USA). Image acquisition and stimulus application were synchronized ...
-
bioRxiv - Cell Biology 2020Quote: ... on to 1×105 adhered U–2–OS or U–2–OS Flp-In T-Rex cells in 2 mL media in a 3.5 cm glass bottom dish (FD35–100, WPI). 8 hr following transfection ...
-
bioRxiv - Immunology 2021Quote: ... Barrier integrity of ALI cultures was monitored by measuring trans-epithelial electrical resistance (TEER, EVOM 2, World Precision Instruments). ALI cultures were validated for use in experiments based on microscopic appearance of appropriate ciliated morphology and TEER > 500 Ω*cm2 ...
-
bioRxiv - Cell Biology 2021Quote: ... TEER values were determined daily beginning on day-2 using an epithelial volt/ohm meter (EVOM2, World Precision Instruments) and STX2 series chopstick electrodes as described previously (23).
-
bioRxiv - Neuroscience 2024Quote: ... For all surgical procedures mice were anesthetized using 1.5-2% isoflurane and were injected using a Kopf stereotaxic and World Precision Instruments (WPI) microinjection syringe pump with a 10 mL syringe and 33g blunt needle at 50-100 nL/min ...
-
bioRxiv - Neuroscience 2024Quote: ... Embryos were loaded into a 2% agarose gel mold and a pre-pulled glass needle (World Precision Instruments, Sarasota) was filled with 10 μL of the injection medium ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (2-4 MΩ) were pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments) on a Sutter P-97 puller (Sutter Instruments Company ...
-
bioRxiv - Neuroscience 2021Quote: ... 2.0-2.3 mm lateral to midline and 2.0-2.5 mm posterior to bregma) at a rate of 60 nL/min at a concentration of 2 mM using a Nanoliter 2020 system (WPI). Optogenetic silencing of V1 was achieved by the use of mice in which channelrhodopsin-2 expression was driven by cre in parvalbumin positive interneurons (Ai32 x PVcre) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (2–5 MΩ) were pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments) on a Sutter P-97 puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... 1010 gc AAV8 in 1-2 μl was stereotactically injected with 15 nl/sec using a microinjection system (Nanoliter 2010, WPI) at (X ...
-
Red Algae-Derived Mineral Intervention to Counter Pro-inflammatory Activity in Human Colon OrganoidsbioRxiv - Molecular Biology 2022Quote: ... TEER values were determined daily with an Epithelial Volt ohm meter 2 (EVOM2) epithelial volt/ohm meter (World Precision Instruments) and STX2 series chopstick electrodes.
-
bioRxiv - Biochemistry 2023Quote: ... 1×105 U-2 OS or U-2 OS Flp-In T-Rex cells were seeded in 35 mm glass bottom dishes (FD35-100, WPI); cells were transfected with 1-2 µg of pcDNA5 FRT/TO plasmids containing the gene of interest using GeneJuice transfection reagent (Cat#70967 ...
-
bioRxiv - Neuroscience 2023Quote: ... The compound solutions were perfused into the chamber and cells via a multichannel perfusion system (MPS-2, World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... and injected with a volume of 2 μL at a rate of 20 nL/s (Micro4, World Precision Instruments, USA) into the vitreous cavity (51730D ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell patch-clamp recordings were made using electrodes (2-6MΩ) pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments). They were filled with a pipette solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (2–4MU) were pulled from filamental borosilicate glass capillaries (1.5 mm OD, 0.84 mm ID; World Precision Instruments) Patch pipettes were filled with internal solution containing (mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... we applied 1-s pressure pulses (0.4-0.6 psi) every 2 s for 1 min by a microinjector (PV850, World Precision Instruments). In some experiments ...
-
bioRxiv - Neuroscience 2021Quote: ... and the injection needle (34 g, beveled; WPI) was lowered 0.6 mm at a 0° polar angle ...
-
bioRxiv - Microbiology 2022Quote: ... 5-day-old 129sv or Stat1-/- pups were orally inoculated with rRRV-HuNoV-VP1 (3.9×105 FFU/pup) and intraperitoneally injected with rRRV-HuNoV-VP1 (3.9×105 FFU/pup) at 9 weeks post-inoculation (WPI). Blood and stool samples were collected at 4 ...
-
bioRxiv - Neuroscience 2022Quote: ... a subgroup of mice (6 NaCl, 9 KA) were implanted with wire electrodes (platinum-iridum, teflon-insulated, Ø125μm, WPI) into the dentate gyrus (DG ...
-
bioRxiv - Neuroscience 2023Quote: ... Fire-polished recording pipets with resistances ranging from 5-9 MΩ were pulled from borosilicate glass (World Precision Instruments). The patch pipette was filled with 120mM KCl ...
-
bioRxiv - Neuroscience 2021Quote: ... +/−2.6mm ML, −4.5mm DV) using a 10μL syringe (nanofil, World Precision Instrument, USA) with NanoFil Needle (NF33BV-2, World Precision Instruments, USA) at a rate of 100nL/min (Micro4 pump ...
-
bioRxiv - Bioengineering 2021Quote: ... Electrochemical characterizations were performed in a three-electrode configuration, using a thick (2-mm diameter, ~5 mm2) Pt wire (WPI, 99.99%) as counter electrode (CE ...
-
bioRxiv - Neuroscience 2021Quote: ... then mounted lateral-side up on a thin layer of 1.5-2% low-melt agarose in a tissue culture dish with a cover-glass bottom (World Precision Instruments) and covered in E3 media ...
-
bioRxiv - Neuroscience 2020Quote: ... The craniotomy was sealed with agarose (1.5–2%, dissolved in artificial cerebrospinal fluid) and a 5 mm glass coverslip (World Precision Instruments) was placed over it ...
-
bioRxiv - Neuroscience 2020Quote: ... VP neurons were visualized using an Olympus BX51WI microscope and recorded from using glass pipettes (1.3-2 MΩ, World Precision Instruments) filled with internal solution (in mM ...
-
bioRxiv - Bioengineering 2022Quote: ... a 2-mm diameter craniotomy was then made over the fiducial mark and covered with KwikCast (World Precision Instruments, FL, USA). The mouse then recovered overnight before the recording session.
-
bioRxiv - Cell Biology 2022Quote: ... TEER was measured with was monitored daily using an epithelial tissue volt ohmmeter (EVOMX) with STX-2 chopsticks (World Precision Instruments). TEER measurements were calculated in ohms cm2 after subtracting the blank value for the membrane insert ...
-
bioRxiv - Neuroscience 2023Quote: ... 1474) and a 75-200 nL volume of viral vector was injected using a microinjector pump (World Precision Instruments, UMP3T-2) with an attached 10-μL NanoFil syringe (World Precision Instruments ...
-
bioRxiv - Cell Biology 2023Quote: ... was injected using a 5-µl Hamilton syringe at a rate of 0.25µl/min during 2 min with a mini-pump (UltraMicroPump III, World Precision Instruments, USA). The same volume of the dye Evans Blue (Sigma ...
-
bioRxiv - Cancer Biology 2023Quote: ... A suspension of 100,000 cells/2 µl/injection was then slowly injected using an UltraMicroPump III and a Micro4 Controller (World Precision Instruments). Post-surgical pain was controlled with SQ carprofen ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass pipettes with a resistance of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Bioengineering 2023Quote: ... and a 34 G beveled needle (World Precision Instruments). For the reconstitution of fluorophores ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... potential skin adherences at the tip of the pumps were disconnected and a surgical clip (Reflex clip 9 mm, WPI) was placed instead.
-
bioRxiv - Neuroscience 2020Quote: ... Mice were anesthetized with isoflurane (5% induction, 1-2 % maintenance; Aerrane, Henry Schein) and secured in a rodent stereotaxic apparatus (Model #502063, World Precision Instruments). Buprenex (Buprenorphine ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (5 % induction, 1-2 % maintenance; Aerrane, Henry Schein) and secured in a rodent stereotaxic apparatus (Model #502063, World Precision Instruments). Buprenex (Buprenorphine ...
-
bioRxiv - Neuroscience 2021Quote: ... was inserted in the dorsal horn to carefully deliver CAV virus at 2 nl/s with the aid of electronically controlled nanoinjector (Nanoliter 2010, WPI, FL, US). Three injections ...
-
bioRxiv - Neuroscience 2022Quote: ... for 2 min in a rectangular transparent plexiglass box (induction chamber) and then transferred to a stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% ...
-
bioRxiv - Genetics 2020Quote: ... phenol red was injected into the yolk of 1- to 2-cell-stage embryos with a Pneumatic PicoPump pv280 (World Precision Instruments). After injection ...
-
bioRxiv - Neuroscience 2021Quote: ... Approximately 1 µl (2 x 1010 GC/hemisphere) virus was dispensed using a NanoFil syringe with a 33G beveled needle (World Precision Instruments). The other hemisphere was injected in the same way ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings from GPe neurons were obtained using micropipettes (2–4MΩ) made from 1.5 mm OD/1.12 mm ID borosilicate glass with a filament (World Precision Instruments, Sarasota, FL) pulled with a P-97 puller (Sutter Instruments Novato ...
-
bioRxiv - Neuroscience 2023Quote: ... 20 nl of the Cre-dependent helper virus was injected to the HDB (bilateral, n = 2; unilateral, n = 1) using a Nanoliter 2010 microinjection pump (World Precision Instruments). The injection coordinates were defined by a stereotaxic atlas (Paxinos and Franklin ...
-
The CB1 receptor interacts with cereblon and drives cereblon deficiency-associated memory shortfallsbioRxiv - Neuroscience 2023Quote: Adult mice (2 months-old) were anaesthetized with isoflurane (4%) and placed into a stereotaxic apparatus (World Precision Instruments, Sarasota, FL, US). Adeno-associated viral particles were injected with a Hamilton microsyringe (Sigma-Aldrich #HAM7635-01 ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus solution (0.4-0.6 µL) was injected at a rate of 2 nL/s with a microinjection pump (either Neurostar NanoW or WPI NanoLiter 2010). The pipette was slowly withdrawn at least 10 minutes after the completion of the injection ...
-
bioRxiv - Cell Biology 2024Quote: ... and injected with 3 μl of AAV9-hSyn-iCre (titer 1 x 1013 to 2 x 1014) into the right lateral ventricle using a nanoliter injector (World Precision Instruments; Micro4 MicroSyringe Pump Controller connected with Nanoliter 2000 ...
-
bioRxiv - Neuroscience 2023Quote: Patch electrodes of 5-7 MΩ resistance (thin wall, filament, 1.5 mm, WPI, Florida, USA) were pulled on DMZ Zeitz-Puller (Zeitz-Instruments Vertriebs GmbH ...
-
bioRxiv - Neuroscience 2023Quote: Intracortical injections were made at multiple sites (∼5-9 sites per cranial window, spaced 0.5-1 mm apart) using a microinjector (NanoFil, World Precision Instruments) fit with a 36G beveled needle (NF36BV-2 ...