Labshake search
Citations for World Precision Instruments :
251 - 300 of 625 citations for 4S 6 8 difluoro 3 4 dihydro 2H 1 benzopyran 4 ol since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... 200 nl of 1:1 mixture of AAV5 CAG-FLEx-TCb and AAV8 CAG-FLEx-RG was injected into the PVH at a speed of 50 nl/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For local circuit mapping (Fig ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5-inch-long needle attached to a 5 µl Hamilton syringe was mounted to the stereotaxic frame and controlled using a Micro 4 Microsyringe Pump (World Precision Instruments) to infuse 0.5 µl AAV2/PHP.eB-hGfaABC1D-DIO-hTDP43-WT (1.2 × 1013 particles/µl) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes for patch clamping were prepared freshly on the day of electrophysiology experiments from filamented glass capillaries (1B150F-4, World Precision Instruments) using a horizontal pipette puller (P1000 ...
-
The CB1 receptor interacts with cereblon and drives cereblon deficiency-associated memory shortfallsbioRxiv - Neuroscience 2023Quote: Adult mice (2 months-old) were anaesthetized with isoflurane (4%) and placed into a stereotaxic apparatus (World Precision Instruments, Sarasota, FL, US). Adeno-associated viral particles were injected with a Hamilton microsyringe (Sigma-Aldrich #HAM7635-01 ...
-
bioRxiv - Neuroscience 2023Quote: ... A total of 250 nL AAV was dispensed at each cortical layer through a glass-capillary-attached Hamilton syringe at a rate of 40 nL/min using a UltraMicroPump-4 system (World Precision Instruments). To image UDP in hippocampus ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV serotype 9 OTp-mCherry was bilaterally injected into the PVH and the supraoptic nucleus at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV8 hSyn-DIO-hM3Dq-mCherry or AAV5 hSyn-DIO-mCherry was bilaterally injected into the PVH at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). The coordinates for injection into the supraoptic nucleus were as follows ...
-
Dietary potassium and cold acclimation additively increase cold tolerance in Drosophila melanogasterbioRxiv - Physiology 2024Quote: ... The ion-selective microelectrodes used to measure hemolymph [K+] were fashioned from glass capillaries (TW150-4, World Precision Instruments, Sarasota, FL, USA) and pulled to a ∼ 1-3 mm tip on a Flaming-Brown micropipette puller (P-1000 ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were plated onto either 13 mm 1.5 glass coverslips in 4-well plates or FluoroDish 35 mm dishes ready coated with poly-D-lysine (PDL) (World Precision Instruments). Glass coverslips were coated with 0.1 ug/ul PDL for 20 minutes and washed once with F12 ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Freshly isolated PAs were cannulated with glass micropipettes (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments) bathed with 37 °C PSS (PSS0Caplus 1.6 mM CaCl2 and without EDTA ...
-
bioRxiv - Bioengineering 2024Quote: ... Glass capillaries (1 mm outer diameter/0.75 mm inner diameter, World Precision Instruments TW100-3) were pulled on a Flaming/Brown type pipette puller (Sutter Instruments P- 97) ...
-
bioRxiv - Cell Biology 2020Quote: ... and stiff pulling pipette (WPI TW100-6) were used for stretching chromosomes ...
-
bioRxiv - Biophysics 2020Quote: ... The signal from the force transducer was amplified using Transbridge TBM4M and digitized using Lab-Trax-4 data acquisition hardware (WPI, Sarasota, FL, USA). Three phases could be distinguished on force curves recorded using LabScribe v3 (iWorks ...
-
bioRxiv - Microbiology 2020Quote: The permeability of the differentiated epithelial layer (after 4 weeks of differentiation) was determined by measuring the TEER using an epithelial volt-ohm meter (EVOM2, World Precision Instruments, Inc.). The EVOM2 was calibrated according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus was injected via a pulled needle of a borosilicate glass capillary (ID: 0.68mm, OD: 1.2mm; Kwik-fill, World Precision Instruments Inc., # 1B150F-4) that was angled at 50° to the slice using a stereotactic micromanipulator (SM-11 ...
-
bioRxiv - Neuroscience 2024Quote: ... Local field-potential (LFP) activity was recorded using a patch pipette prepared from thin-borosilicate glass (1.5mmOD, 0.84mmID, World Precision Instruments, cat.no. 1B150F-4) pooled and fire-polished on a Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2024Quote: Glass capillary tubes with an inner diameter about 0.2 mm were prepared from thin wall glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL), using puller (PC-100 ...
-
bioRxiv - Bioengineering 2022Quote: ... A glass capillary (1 mm outer diameter/0.75 mm inner diameter, World Precision Instruments TW100-3) was pulled on a Browning/Flaming type pipette puller (Sutter Instruments P-97) ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2022Quote: ... A standard micropipette injection protocol was used to make all injections into the brain or spinal cord using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2020Quote: MC3T3-E1 Subclone 4 (ATCC® CRL-2593™) preosteoblastic cells were cultured on duplicate samples of tissue-cultured polystyrene (Fluorodish, World Precision Instruments) and commercially available argon-treated BC (CoArBC) ...
-
bioRxiv - Biophysics 2023Quote: ... A standard micropipette injection protocol was used to make all injections into the brain using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2024Quote: Molds for the device assembly were fabricated using PDMS and biopsy punches of 4 mm and 7 mm diameters (World Precision Instruments, Sarasota, FL). A large well was made in the PDMS with the 7 mm punch ...
-
bioRxiv - Neuroscience 2024Quote: ... A Hamilton syringe (Hamilton 7635-01) was filled with either PBS or C9-ASO at 50 ng/μL and attached to a microinjection pump (World Precision Instruments Micro 4) on a stereotactic arm ...
-
bioRxiv - Cell Biology 2020Quote: An easily bent force pipette (WPI TW100F-6), and stiff pulling pipette (WPI TW100-6 ...
-
bioRxiv - Neuroscience 2023Quote: ... and 26-gauge needle (Hamilton) at a flow rate of 100 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato, USA or 1B150F-4, World Precision Instruments, Sarasota, USA) in a horizontal pipette puller (P-1000 Micropipette puller ...
-
bioRxiv - Genetics 2023Quote: ... 0.5nl of the mixtures were directly injected into the yolk of freshly layed zygotes using a glass capillary needle [TW120-4) (Kwik-Fil, World Precision Instruments, Inc., Hertfordshire, UK)] with the help of a pedal controlled microinjector (PV820 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2024Quote: ... plasmid was delivered using a glass pipette at a flow rate of 50 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Neuroscience 2020Quote: ... with a 1” 30g blunt needle was mounted into an UMP-3 (World Precision Instruments, Sarasota, FL) injector connected to a SYS-Micro4 controller (both from World Precision Instruments ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... A circular 6 mm biopsy corer (World Precision Instruments) was used to isolate smaller regions of interest from several different tissue blocks and re-embedded into a new block.
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... The vessels were repositioned to display all branches without overlap using a glass capillary (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments, Sarasota, FL) thinned with a micropipette puller (Narishige ...
-
bioRxiv - Cell Biology 2023Quote: ... from day 1 to day 6 of subculture of BMEC onto Transwells® using an EVOM2 Voltohmmeter/STX2 electrodes (World Precision Instruments). The STX2 electrode was positioned within the well and the resistance (Ω ...
-
bioRxiv - Neuroscience 2020Quote: ... pipettes (World Precision Instruments, 1B150F-3) were pulled (Sutter ...
-
bioRxiv - Neuroscience 2021Quote: ... M3516)-filled glass pipette (WPI, TW100F-3) and delivered at rate 30 nl/min using a micro-infusion pump (Harvard Apparatus ...
-
bioRxiv - Neuroscience 2022Quote: ... 30–100nl of virus were injected at a rate of 3–5nl/s at two depths (0.7–0.85, and 0.9–1 mm ventral) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... 1-3% maintenance) and body temperature was maintained at 37.5°C using a temperature controller (ATC2000, World Precision Instruments). Animals were dosed with slow-release buprenorphine (0.1mg/kg ...
-
bioRxiv - Plant Biology 2023Quote: ... Borosilicate glass capillaries (1B150F-6, World Precision Instruments, Sarasota, USA) were used to make micropipettes with the use of a P-30 micropipette puller (Shutter Instrument Co. ...
-
bioRxiv - Neuroscience 2024Quote: ... 6 mL/min) using a peristaltic pump (World Precision Instruments). Brains were excised whole ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were performed with low resistance (1–3 MΩ) glass pipettes (ID: 0.68 mm, OD: 1.2 mm, WPI, Sarasota, FL) filled with aCSF under current-clamp mode with I=0 configuration ...
-
bioRxiv - Developmental Biology 2022Quote: ... glass capillaries (World Precision Instruments TW100-3) were pulled using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass capillaries (WPI, cat. No. 1B100-3) coated with a drop of heparin (50U/ml ...
-
bioRxiv - Neuroscience 2023Quote: ... Using an UltraMicroPump 3 (World Precision Instruments), 5.5 μg of Rho-BR-EVs were injected into the lateral ventricle at a 1 μl/min rate ...
-
bioRxiv - Developmental Biology 2023Quote: ... glass capillaries (World Precision Instruments TW100-3) are pulled using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Bioengineering 2024Quote: ... A 6-channel programmable syringe pump (AL-1600, World Precision Instruments) was used to achieve a flow rate of 5 µL per minute throughout the experiments.
-
bioRxiv - Cell Biology 2024Quote: ... loose chromosome was grabbed by the deflection pipette (WPI TW100F-6) using a MP285 ...
-
bioRxiv - Microbiology 2021Quote: ... that had been prepared on an 8 mm diameter #1.5 circular glass coverslip (WPI). The coverslip-pad-sample assembly was then lifted with forceps and placed ...
-
bioRxiv - Biochemistry 2024Quote: ... Snails were injected using glass capillary needles (World Precision Instruments, 1B100F-6) pulled to an opening size of approximately 100 µm with a Model P-87 Sutter Instrument Micropipette Puller ...