Labshake search
Citations for World Precision Instruments :
2701 - 2750 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: 5–7 dpf larvae were anesthetized in 0.02% MS-222 and embedded in low-melting point agarose (1.5%) in a 10 mm FluoroDish (WPI). Images were acquired on an Olympus FV1200 Confocal microscope equipped with high sensitivity GaAsP detectors (filter cubes FV12-MHBY and FV12-MHYR) ...
-
bioRxiv - Neuroscience 2021Quote: ... was transferred to a glass Petri dish to which it was glued with KWIK-SIL (World Precision Instruments, Berlin, Germany). The Petri dish was filled with ECi and then placed on the stage of an upright CFS 6000 microscope equipped with a TCS-SP5 AOBS scan head (Leica Microsystems ...
-
bioRxiv - Neuroscience 2021Quote: ... AAV virus was injected with a glass pipette using an infusion pump (Micro 4, WPI, USA). Viruses were injected bilaterally into target brain areas using the following coordinates ...
-
bioRxiv - Neuroscience 2021Quote: ... into ipsilateral mPFC (Nanofil Syringe and Pump UMP3, World Precision Instruments). Coordinates for injection into ipsilateral mPFC were (in mm relative to Bregma) ...
-
bioRxiv - Neuroscience 2021Quote: ... A borosilicate glass capillary (1B100F-3; World Precision Instruments, Sarasota, FL) was filled with 10% sucrose water and embedded into a cotton plug ...
-
bioRxiv - Neuroscience 2021Quote: ... The syringe was mounted into a motorized microinjector (UMP3T-2, WPI) that was held by a manipulator (model 1460 ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses were pressure-injected using a 10-μL Nanofil Syringe (NANOFIL, WPI, USA) with a 33-gage beveled Nanofil needle (NF33BV-2 ...
-
bioRxiv - Neuroscience 2021Quote: ... 1.5% maintenance) and body temperature was maintained at 37.5°C using a temperature controller (ATC2000, World Precision Instruments). Animals were dosed with slow-release buprenorphine (0.1mg/kg ...
-
bioRxiv - Neuroscience 2021Quote: ... USA) was injected using a 10 µl syringe and an ultra-micro pump (UMP3 with SYS-Micro4 Controller, WPI, UK) and 35 G needles on a micron-resolution manipulator ...
-
bioRxiv - Neuroscience 2021Quote: ... and controller (World Precision Instruments). The coordinates for viral injection were +2.8 / +3.2 mm from midline (M-L axis) ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 33-gage beveled Nanofil needle (NF33BV-2, WPI). The syringe was mounted into a motorized microinjector (UMP3T-2 ...
-
bioRxiv - Neuroscience 2021Quote: ... A Micro-1 microsyringe pump controller (World Precision Instruments) was used to inject 1.5 μl of virus at a constant rate over 10 minutes ...
-
bioRxiv - Neuroscience 2021Quote: ... in 6 steps consisting of 50 nl pulses every 50 μm on the left side (400 μm lateral from the midline) of the spinal cord using a 0.5 μl Hamilton syringe mounted on a UMP3 UltraMicroPump (WPI). Skin was then sutured with a nylon surgical suture ...
-
bioRxiv - Neuroscience 2021Quote: ... The reward during the tasks was a viscous solution of gum arabic (gum arabic powder, Willy Benecke, Germany) applied through a syringe pump (AL-1000HP, WPI, USA) that was controlled by a custom Arduino-based circuit ...
-
bioRxiv - Neuroscience 2021Quote: ... the craniotomy was filled with kwik-sil (World Precision Instruments, Inc., Sarasota, FL, USA) and covered with cyanoacrylate glue (Super Glue ...
-
bioRxiv - Neuroscience 2021Quote: ... Current pulses (0.2 ms, 50 ms interpulse intervals) was provided by a stimulus isolator (WPI, cat. #A365) and adjusted for each cell to produce ∼90% success rates ...
-
bioRxiv - Neuroscience 2021Quote: ... and 400-500 nl of AAV was injected using a microsyringe pump (Nanoliter 2000 injector, WPI) at the following coordinates ...
-
bioRxiv - Neuroscience 2021Quote: ... The micropressure application of drugs was controlled using a Pneumatic PicoPump PV800 (World Precision Instruments). Hypotonic solutions were delivered by perfusion ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes (World Precision Instruments, Inc., USA) were made by a Narishige puller (PP-830 ...
-
bioRxiv - Neuroscience 2021Quote: Electrodes were pulled from a borosilicate glass microcapillary (1.00 mm; World Precision Instruments) using a laser puller (Sutter Instruments co ...
-
bioRxiv - Neuroscience 2021Quote: ... in a recording chamber (Fluorodish, World Precision Instruments). To ensure odor to arrive to the nostrils ...
-
bioRxiv - Neuroscience 2021Quote: ... The CNS was stabilized on the coverslip using tissue adhesive (Gluture, World Precision Instruments, USA). The aCC or RP2 cells ...
-
bioRxiv - Neuroscience 2021Quote: ... The electrode was fixed to the skull using dental cement (C&B Metabond) and surrounding skin was sealed using GLUture (WPI Inc.). Mice were monitored for 7 days post-surgery to ensure proper recovery.
-
bioRxiv - Neuroscience 2021Quote: ... connected to a microsyringe pump (World Precision Instruments, UMP3 UltraMicroPump). Coordinates for injections into PFC were (in mm ...
-
bioRxiv - Neuroscience 2021Quote: ... Skin adjacent to the dental cement was sealed using GLUture (WPI Inc.). Mice received gentamicin (i.m ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected (at the rate of 100 nl/min) with a microinjection syringe (Nanofil 10 µl with 35 gauge needle, World Precision Instruments) connected to a microsyringe pump (World Precision Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... and injections were carried out using a Micro4 injection pump controller (World Precision Instruments). Viruses were bilaterally injected (1 μl per site ...
-
bioRxiv - Neuroscience 2021Quote: ... A solution containing 100-200 nl viral construct was loaded into a pulled glass capillary and injected into the target region using a Nanoinjector (WPI). Optic fibers (0.2 mm diameter ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass capillary tubes (Kwik-Fil 1B150F-4, World Precision Instruments, Hitchin, United Kingdom) were pulled using a Model P90 micropipette puller (Sutter instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes (2-4MΩ) were pulled from borosilicate glass (Schott no. 8250; World Precision Instruments, Sarasota, FL, USA) with a Sutter P-97 puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... was done after 7s of baseline recording using an A385 current isolator and a SYS-A310 Accu pulser signal generator (World Precision Instruments). 2% NaN3 was added by directly injecting into the imaging chamber after 30s to achieve immediate mixing ...
-
bioRxiv - Neuroscience 2021Quote: ... and fine flexible injection cannula (MicroFil 34 AWG, MF34G-5, World Precision Instruments, Ltd.). The pipettes were connected to the iontophoresis unit (Neurophore-BH- 2 ...
-
bioRxiv - Neuroscience 2021Quote: ... The DRG were covered with silicone elastomer (World Precision Instruments, Ltd) to maintain a physiological environment ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses were injected using a glass micropipette (WPI, 1B120F-4) filled with mineral oil attached to Nanoliter Injector with SMARTouch Controller (WPI ...
-
bioRxiv - Neuroscience 2021Quote: ... Using a microsyringe (33GA; Hamilton syringe, Reno, NV) connected to an UltraMicroPump (World Precision Instruments, Saratosa, FL) virus was subsequently injected at a flow rate of 50-100nl/min ...
-
bioRxiv - Neuroscience 2021Quote: ... were used for immunocytochemistry and FluoroDish (FD35-100, World Precision Instruments) were used for live single axon imaging ...
-
bioRxiv - Bioengineering 2021Quote: ... The culture medium in the trachea lumen and within the chamber was refreshed via a syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and a programmable pump (flow rate ...
-
bioRxiv - Bioengineering 2021Quote: ... of either 2% or 4% SDS solution was infused through the trachea using a programmable syringe pump (flow rate: 6.3 mL.s-1; AL-4000, World Precision Instruments) to generate a thin film of the detergent solution on the luminal surface of the trachea.49,51 To promote de-epithelization ...
-
bioRxiv - Bioengineering 2021Quote: ... the culture medium within the inner space of the trachea was replaced with the fresh medium once a day using a programmable syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and the removed culture medium was collected in a waste reservoir ...
-
Interleukin 4 controls the role of macrophages in pulmonary metastatic tumor cell seeding and growthbioRxiv - Cancer Biology 2021Quote: ... Trans-endothelial resistance was measured using EndOhm-6 chamber and EVOM2 resistance meter (World Precision Instruments) and expressed as a function of the effective surface area of the filter membrane (Ω x cm2) ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The left epandrial lobe was shortened to various lengths with micro dissection scissors (SuperFine Vannas Scissors, World Precision Instruments). Flies were let to recover for at least 7 days on standard D ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes were pulled from borosilicate glass capillaries with an inner filament (1.5 mm outer diameter; World Precision Instruments Inc., Sarasota, FL) on a pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2021Quote: ... 5kHz and 10 kHz were generated by custom made script and applied to the slice through a stimulus isolator A395 (WPI, Lawrence, PA). Occasional DC offsets were monitored and neutralized when they occurred ...
-
bioRxiv - Neuroscience 2021Quote: ... Immediately after the stabilization of Rl of REPL-NG/ONCM complex or REPL-NG was injected into the L4 and L5 DRG at a rate of 0.25 μl/min using a nanoinjector (#M3301R, World Precision Instruments). For intraganglionic injection ...
-
bioRxiv - Neuroscience 2021Quote: ... 2 μl of AAV5-CCL2 or AAV5-GFP was injected into the L5 DRG at a rate of 0.25 μl/min using a nanoinjector (#M3301R, World Precision Instruments). The recombinant AAV vector containing ONCM or SS-ONCM expression cassette was generated from pCMV-ONCM and pCMV-SS-ONCM ...
-
bioRxiv - Molecular Biology 2021Quote: Microinjection needles were prepared from thin wall borosilicate glass capillaries with filament (Outer diameter 1.0mm, inner diameter 0.75mm. World Precision Instruments, Sarasota, USA) on a micropipette puller (P-1000,Sutter Instruments ...
-
bioRxiv - Biophysics 2021Quote: ... Borosilicate glass capillaries (World Precision Instruments) were used with a resistance of 0.1–0.3 MΩ when filled with 3 M KOAc and 10 mM KCl ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... The polyethylene slide was positioned immediately below the flower with the aid of a micromanipulator (M330 with M3 tilting base and 2.5kg weight; World Precision Instruments, Hitchin, UK). After the vibration was applied ...
-
bioRxiv - Developmental Biology 2021Quote: ... Transplantation needles were prepared by pulling thin glass capillaries (WPI, USA) using an electric puller (Narishige ...
-
bioRxiv - Developmental Biology 2021Quote: Deskinned embryos were glued to FluoroDish dishes (World Precision Instruments, FL USA, cat no. FD5040-100) using CELL-TAK (Corning ...