Labshake search
Citations for World Precision Instruments :
201 - 247 of 247 citations for Calcium calmodulin Dependent 3' 5' Cyclic Nucleotide Phosphodiesterase 1C PDE1C Antibody since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Cells expressing YFP and with a soma diameter <25 µm were targeted for whole cell recording using pipettes (∼5 MΩ resistance) pulled from borosilicate glass (WPI).
-
bioRxiv - Neuroscience 2019Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion and reduce spread up the infusion tract ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Neuroscience 2020Quote: ... were applied with a glass pipette (2-3 μm diameter) positioned 20 to 30 μm away from the soma and connected to a picospritzer (World Precision Instruments, adjusted to ~2 psi). All electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Neuroscience 2021Quote: ... Constant current stimuli (0.5 μA-5 mA) were applied using a high-voltage stimulus isolator (A365R, World Precision Instruments, Sarasota, FL). The evoked mono and polysynaptic IPSCs were recorded simultaneously in GCs and SGC pairs ...
-
bioRxiv - Bioengineering 2021Quote: ... Electrochemical characterizations were performed in a three-electrode configuration, using a thick (2-mm diameter, ~5 mm2) Pt wire (WPI, 99.99%) as counter electrode (CE ...
-
bioRxiv - Systems Biology 2021Quote: ... 1 mM beta-glycerol phosphate and 5 mM of sodium orthovanadate) using a syringe pump (Aladdin AL-1000, World precision instruments). Livers and right kidneys were quickly removed and snap frozen in liquid nitrogen ...
-
bioRxiv - Neuroscience 2020Quote: ... The craniotomy was sealed with agarose (1.5–2%, dissolved in artificial cerebrospinal fluid) and a 5 mm glass coverslip (World Precision Instruments) was placed over it ...
-
bioRxiv - Microbiology 2019Quote: ... They were filled with a 1M KCl solution using a MicroFil non-metallic syringe needle (MF 34G-5, World Precision Instruments).
-
bioRxiv - Neuroscience 2022Quote: ... was injected iontophoretically (0.8—1.0 μA positive current pulses with a 7 s-on/off cycle for 5 min using A365, World Precision Instruments). The coordinates of the injection were [AP −2.9 ...
-
bioRxiv - Developmental Biology 2019Quote: ... A total of 1-5 nl mRNAs were microinjected into one-cell stage wild-type zebrafish embryo using the WPI microinjector (WPI, USA). The 1-2 dpf embryos were anesthetized in 0.016% tricaine and photographed under a Leica stereomicroscope.
-
bioRxiv - Bioengineering 2021Quote: ... The culture medium in the trachea lumen and within the chamber was refreshed via a syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and a programmable pump (flow rate ...
-
bioRxiv - Bioengineering 2021Quote: ... the culture medium within the inner space of the trachea was replaced with the fresh medium once a day using a programmable syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and the removed culture medium was collected in a waste reservoir ...
-
bioRxiv - Neuroscience 2023Quote: Intracortical injections were made at multiple sites (∼5-9 sites per cranial window, spaced 0.5-1 mm apart) using a microinjector (NanoFil, World Precision Instruments) fit with a 36G beveled needle (NF36BV-2 ...
-
bioRxiv - Bioengineering 2023Quote: ... Drugs were infused over 5 minutes intravenously via a tail vein catheter with an infusion pump (World Precision Instruments, Sarasota, FL). Focused ultrasound was applied after 2.5 minutes of drug infusion for 2.5 minutes (250 kHz ...
-
bioRxiv - Neuroscience 2020Quote: ... Mice were anesthetized with isoflurane (5% induction, 1-2 % maintenance; Aerrane, Henry Schein) and secured in a rodent stereotaxic apparatus (Model #502063, World Precision Instruments). Buprenex (Buprenorphine ...
-
bioRxiv - Cell Biology 2019Quote: ... cells were plated as single cells (5 × 105 cells) on 35 mm FluoroDish Cell Culture Dishes (World Precision Instruments, cat. WD35-100) and allowed to attach for 72 h ...
-
bioRxiv - Physiology 2019Quote: ... TEER values were determined on days-2 and −5 with an Epithelial Volt ohm meter 2 (EVOM2) and STX2 series chopstick electrodes (World Precision Instruments).
-
bioRxiv - Neuroscience 2019Quote: ... Anesthesia was induced at 5% isofluorane in O2/N2O mixture (Rothacher Medical GmbH., Switzerland) and mice were placed in the stereotaxic frame (World Precision Instruments). During surgery ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (5 % induction, 1-2 % maintenance; Aerrane, Henry Schein) and secured in a rodent stereotaxic apparatus (Model #502063, World Precision Instruments). Buprenex (Buprenorphine ...
-
bioRxiv - Cell Biology 2021Quote: ... was injected into each hemisphere of the M1 motor cortex using a glass pipette (tip diameter 5∼8 mm) at a rate of 100 nl/min using a syringe pump (Micro4; World Precision Instruments). The injection site was standardized among animals by using stereotaxic coordinates (ML = ±1.50 ...
-
bioRxiv - Neuroscience 2022Quote: ... rats were deeply anaesthetised with urethane and lesions were made at the tip of the tetrodes using a 30 μA unipolar current for 5 – 10 s (Stimulus Isolator, World Precision Instruments). Then ...
-
bioRxiv - Neuroscience 2022Quote: ... Neural signals were amplified (20,000 X) and filtered (300 Hz – 5 kHz) through an isolated amplifier (ISO-Dam 80, WPI, Sarasota, FL, USA). The microelectrode was manually guided into a cutaneous fascicle by delivering weak electrical pulses (0.2 ms ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5-inch-long needle attached to a 5 µl Hamilton syringe was mounted to the stereotaxic frame and controlled using a Micro 4 Microsyringe Pump (World Precision Instruments) to infuse 0.5 µl AAV2/PHP.eB-hGfaABC1D-DIO-hTDP43-WT (1.2 × 1013 particles/µl) ...
-
bioRxiv - Neuroscience 2022Quote: ... They were filled with a 1 M KCl solution using a MicroFil non-metallic syringe needle (MF 34G-5, World Precision Instruments); a few recordings were done with 3 M KCl (no particular change was noticed).
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 1 and 5 MΩ using a MF-200 microforge (World Precision Instruments). An agar bridge (1M KCl ...
-
bioRxiv - Cell Biology 2023Quote: ... Cells were incubated for 60 min in 5% CO2 at 37°C in suspension before adding to glass-bottom dishes (FluoroDish, FD35-100, World Precision Instruments) or 12-mm diameter coverslips (Fisherbrand 1254580 ...
-
bioRxiv - Biophysics 2024Quote: ... A Polydimethylsiloxan (PDMS) stencil with a circle area of 5 [mm] was placed inside a bottom glass dish (FluoroDish, World Precision Instruments), which is a 35 [mm] diameter glass bottom dish ...
-
bioRxiv - Neuroscience 2021Quote: ... we filled the central barrel (with the tungsten electrode inside) with superglue using a syringe and fine flexible injection cannula (MicroFil 28 AWG, MF28G67-5, World Precision Instruments, Ltd.). We found that if we did not fill (most of ...
-
bioRxiv - Neuroscience 2021Quote: ... Injectors were connected via flexible polyethylene tubing to 5-µl SGE micro-syringes mounted on a microinfusion pump (sp200IZ, World Precision Instruments, UK). A volume of 0.5µl/side of either 0.9 % sterile saline (vehicle ...
-
bioRxiv - Neuroscience 2023Quote: ... Electrical hindpaw stimulation was applied with 1 msec 5 mA current pulses using an isolated current stimulator (A382, World Precision Instruments, Sarasota, Florida). For each stimulation condition ...
-
bioRxiv - Neuroscience 2022Quote: ... cells were treated with 12-h αSN-AGs (5% v/v) for 16 h and TEER was measured using the EVOM2 apparatus with STX2 chopstick electrodes (World Precision Instruments, USA).
-
bioRxiv - Neuroscience 2023Quote: ... Bipolar stimulation electrodes were placed on the unopened spinal cord to transmit low-intensity (5–8 V) electrical pulses generated by an isolated stimulator (A 360, WPI, Sarasota, FL, USA). This allowed antidromic activation of the M-cell axons ...
-
bioRxiv - Neuroscience 2019Quote: Eight to eleven weeks old injected mice were anesthetized with 5% of isoflurane a 1.5% of oxygen into the anesthesia system box (World Precision Instruments, Ref. EZ-B800) for 5 minutes ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2020Quote: Extracellular single-unit recordings confined to superficial cerebellar cortical layers were obtained in the awake animal during the reaching task using either parylene-insulated tungsten microelectrodes (WPI, impedance 2-5 MΩ) or a 16 channel Vector Array microelectrode (Neuronexus ...
-
bioRxiv - Physiology 2021Quote: The mixed sample was then transferred to a 5 mL syringe and perfused using an Aladdin AL-1000 syringe pump (World precision instruments, United Kingdom) through the ibidi slide ...
-
bioRxiv - Cell Biology 2023Quote: ... The micropipette was bent to a desired degree by heating it over an alcohol lamp and was filled with phosphate-buffered saline (PBS) using the MicroFil (World Precision Instruments, MF34G-5). The micropipette was installed to a micropipette holder ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were obtained using tungsten electrodes (TM31C40KT, 4-MΩ impedance at 1 kHz or TM31A50KT, 5-MΩ impedance at 1 kHz; World Precision Instruments Inc., Sarasota FL, USA). All recordings were pre-amplified in the DC mode ...
-
bioRxiv - Neuroscience 2023Quote: ... covered with cells was placed between two plates and an oscillatory pressure-driven fluid flow was propelled through it using 5 mL syringes (Terumo®) mounted on a programmable double syringe pump (AL-4000; World Precision Instruments®, Hertfordshire, UK). The flow rates of 22.45 mL/min and 4.49 mL/min at 0.5 Hz were used to obtain a shear stress magnitude of 0.1 and 0.5 Pa ...
-
bioRxiv - Neuroscience 2020Quote: ... The CO2 stimulus was pulsed through a separate delivery system that delivered controlled pulses using a PSM 8000 microinjector (WPI, Sarasota, FL., variable 5 mL s−1) into the same humidified airstream ...