Labshake search
Citations for World Precision Instruments :
151 - 181 of 181 citations for Human Dual Specificity Phosphatase 3 DUSP3 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... A recording pipette with a resistance of 3–6 MΩ was pulled from a borosilicate glass capillary (World Precision Instruments, Sarasota, FL) using a micropipette puller (Model P-97 ...
-
bioRxiv - Bioengineering 2022Quote: ... The needle was allowed to sit in place for approximately 5 min and 3-5 μL of viral vector was injected using a microsyringe pump (World Precision Instruments, UMP3) and pump controller (World Precision Instruments ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: Micropipettes with a tip resistance of 3–6 MΩ were prepared from 1.2/0.69-mm OD/ID borosilicate glass capillaries (World Precision Instruments, GC-120F-10) using a pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... filled with normal ACSF) using a DAM-80 amplifier (low filter, 1 Hz; high pass filter, 3 KHz; World Precision Instruments, Sarasota, FL). Mossy fiber-mediated fEPSP were evoked by weak electrical stimulations performed via a bipolar NiCh electrode (NI-0.7F ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral Injections were unilaterally or bilaterally delivered using a syringe (65458-01, Hamilton, USA) controlled by an ultra-micropump (UMP-3, World Precision Instruments, USA) at a rate of 0.1 µl/min (total volume of 0.6 µl for slice imaging and 0.4 µl for fiber photometry) ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the cells were injected at the position 2 mm to the right lateral bregma and 3 mm deep with a flow of 0.2 μL/min utilizing a 10 μL precision micro syringe (World Precision Instruments, Florida, USA) with a 34-gauge needle ...
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
Polyunsaturated Fatty Acid - mediated Cellular Rejuvenation for Reversing Age-related Vision DeclinebioRxiv - Molecular Biology 2024Quote: ... connected to an RPE-KIT (World Precision Instruments) by SilFlex tubing (World Precision Instruments ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
Clemizole and Trazodone are Effective Antiseizure Treatments in a Zebrafish Model of STXBP1 DisorderbioRxiv - Neuroscience 2022Quote: ... gap-free local field potential recordings (LFP; 60 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3) filled with 2 mM NaCl internal solution (~1 μm tip diameter ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole cell voltage and current-clamp recordings were performed at 32–34 °C with electrodes (3–5MΩ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with intracellular solution of the following composition (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... gap-free local field potential recordings (LFP; 15 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3); ~ 1 μm tip diameter ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were subject to nano-electrospray ionization (nESI) in positive ion mode (at ∼2 kV) with a pulled nanospray tip (World Precision Instruments 1B100-3) prepared as detailed in (48) ...
-
bioRxiv - Bioengineering 2021Quote: ... New Jersey) and custom 3D-printed components was assembled around the animal to support a 3-axis micromanipulator (502600, World Precision Instruments, Sarasota, FL) and linear actuator (M-235.5DD ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-6 MΩ) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... at least 3 days before the day of injection and the craniotomies were covered with silicone elastomer (Kwik-Cast, World Precision Instruments, FL, USA). Before injection ...
-
bioRxiv - Neuroscience 2023Quote: ... A circular piece of the skull (3 mm in diameter) centered over the injection was carefully cut out using a sharp drill (Ideal micro drill, World Precision Instruments, Berlin, Germany). The dura was removed with forceps and mild vacuum suction was used to slowly remove the cortex within the craniotomy ...
-
bioRxiv - Developmental Biology 2023Quote: ... Ventral longitudinal muscle 6 in abdominal segments 3 or 4 was impaled with two intracellular electrodes (1 mm outer diameter borosilicate capillaries; World Precision Instruments, 1B100F-4) of ∼15 MΩ resistance (3M KCl) ...
-
bioRxiv - Neuroscience 2019Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion and reduce spread up the infusion tract ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Neuroscience 2020Quote: ... were applied with a glass pipette (2-3 μm diameter) positioned 20 to 30 μm away from the soma and connected to a picospritzer (World Precision Instruments, adjusted to ~2 psi). All electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... and a silicon bead (kit-silicone low viscosity, WPI, Sasasota, FL) was placed approximately 10 mm from the tip 15 ...
-
bioRxiv - Bioengineering 2024Quote: ... mounted on an injector assembly (MMP-KIT, WPI, Sarasota, FL, USA), was attached to a micromanipulator and connected to a microsyringe pump (PHD Ultra ...
-
bioRxiv - Molecular Biology 2022Quote: ... A 33G blunt cannula attached to the Micro4 microinjection pump with RPE kit (World Precision Instruments, Sarasota, FL) was inserted into the eye ...
-
bioRxiv - Neuroscience 2023Quote: ... isoflurane was administered in oxygen with a Vapor 19.3 vaporizer (Dräger) and delivered to the animal with an OC-SFM-KIT rodent facemask (WPI). After head and mask fixation ...
-
bioRxiv - Neuroscience 2023Quote: ... and MBH tissue was sampled with Reusable rapid biopsy punch kit with 1.0 mm in diameter (WPI, Hitchin, UK). Sampled tissue punches were flash frozen on dry ice and store at -80 °C until RNA isolation by RNeasy Plus mini kit (Qiagen) ...