Labshake search
Citations for World Precision Instruments :
151 - 200 of 481 citations for 6 N CARBETHOXY 3 CHLORO 7 8 DIHYDRO 5H PYRIDO 4 3 C PYRIDAZINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2022Quote: ... The tip of the pipette was cut to an opening diameter of ∼3 μm and bent to ∼40° using a microforge (WPI, DMF1000). Tethers were pulled with a 4 µm diameter polystyrene bead (Spherotech #DIGP-40-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... We sealed the craniotomy with silicone gel (Dow DOWSIL 3-4680, sometimes called “artificial dura”) and a silicone sealant (WPI KwikCast). We also implanted a stainless steel pin elsewhere on the dorsal surface of the skull ...
-
bioRxiv - Neuroscience 2019Quote: Field EPSPs (fEPSPs) were recorded as previously (19) in CA1 stratum radiatum with glass electrodes (1–3 MΩ; WPI, Saratosa, FL) filled with ASCF ...
-
bioRxiv - Developmental Biology 2024Quote: Erythrocytes were isolated from 3-dpf zebrafish embryos (wild-type and miR-144Δ/Δ) by dissecting their tail using sapphire blade (WPI) and collecting cells in the bleeding buffer (1X PBS containing 2% PBS and 5 mM EDTA) ...
-
bioRxiv - Neuroscience 2020Quote: Test compounds were dissolved in aCSF and locally puff-applied with a patch pipette (4–6 MΩ) at low pressure (∼1 psi) controlled by a Pneumatic Picopump (PV821, World Precision Instruments, USA) for 20 to 90s ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Neuroscience 2022Quote: Mice were anesthetized with 3% isoflurane (Aerrane, Henry Schein) for 2 min and then transferred to the stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% and monitored the same way as described above for IHKA injection ...
-
A novel neural stem cell-derived immunocompetent mouse model of glioblastoma for preclinical studiesbioRxiv - Cancer Biology 2020Quote: ... to the bregma and 3 mm deep at a flow of 0.2 μL/min using a 10-μL precision microsyringe (World Precision Instruments, Inc) with a 34G needle.
-
bioRxiv - Cell Biology 2021Quote: ... were resuspended in 2–3 mg/ml rat-tail collagen I in RM+ medium and seeded on 23-mm FluoroDish cell culture dishes (World Precision Instruments). The collagen with embedded cells was allowed to set at 37°C until collagen contraction was observed (∼30 min) ...
-
bioRxiv - Neuroscience 2020Quote: ... and temperature measurements with a digital thermometer (Fisher Traceable Type-K thermometer) with rodent rectal temperature probe (World Precision Instruments, RET-3). For experiments performed in a cold environment ...
-
bioRxiv - Cell Biology 2022Quote: Pre-warmed assay media (200 μl) was added to the apical surface of the cultures and TEER was measured using an EVOM-3 meter (World Precision Instruments).
-
bioRxiv - Pathology 2022Quote: ... The core body temperature was measured rectally with a Thermometer equipped with a RET-3 mouse rectal temperature probe (WPI, Sarasota, FL).
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2020Quote: ... The reference and recording glass electrodes (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) were pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Bioengineering 2020Quote: ... was injected to separate microfluidic channels in the fiber through tubing connected to a standard precision injection apparatus (100 nl/s, NanoFil Syringe and UMP-3 Syringe pump, World Precision Instruments) while the fiber probe was embedded in 0.6% agarose gel (see details of tubing connection in Multifunctional Neuro Probes Assembly).
-
bioRxiv - Neuroscience 2019Quote: ... Papaverine was locally ejected for ~1 s by 3 times using an air pressure of <15 psi in the pipette (PV830 Pneumatic PicoPump, World Precision Instruments). A red cloud (Alexa 594 ...
-
bioRxiv - Neuroscience 2021Quote: ... 1μL of virus was injected in the dorsal hippocampus and 1μl of virus in the ventral hippocampus (either AAV-miR-499 or AAV-Control) over 3 min via a microinjection pump (World Precision Instruments). The infusion cannula was left in place for an additional 3 min thereafter to allow diffusion ...
-
bioRxiv - Neuroscience 2020Quote: ... Field stimulations (10 Hz*60 s and 30 Hz*3 s) were performed with an A385 current isolator and a SYS-A310 accupulser signal generator (World Precision Instruments). Glycolysis was inhibited with 2-DG [5 mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Extracellular field potentials from de CA1 pyramidal neurons were recorded using a borosilicate glass micropipette (1–3 MΩ; RRID:SCR_008593; World Precision Instruments, Sarasota, US) filled with aCSF positioned on the slice surface in the stratum radiatum of CA1 and connected to the headstage of an extracellular recording amplifier (NeuroLog System ...
-
bioRxiv - Neuroscience 2023Quote: ... Three circular glass coverslip (2 of 3 mm and one 4mm coverslips) was affixed with a clear silicone elastomer (Kwik-sil, World Precision Instruments). A custom 3D-printed stainless steel headpost was attached on the skull and the rest of exposed skull area and the edge of the cranial window were covered using a dental acrylic (C&B Metabond) ...
-
bioRxiv - Neuroscience 2023Quote: ... A connection cable (Plastics One, model 335–340/3) was used to connect the electrodes to a stimulus isolator (WPI, model A365) and the stimulator (AMPI ...
-
bioRxiv - Neuroscience 2023Quote: ... at a rate of 100 nL/minute through a 31-gauge gastight Hamilton syringe attached to a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments) with a 10 minute waiting period prior to the removal of the needle ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purified dsRNA was diluted to 2,000 ng/μL and 3 μg of dsRNA were injected with a Nanoliter (WPI, Sarasota, FL, USA) to the body cavity via the metapleuron under the wing ...
-
bioRxiv - Neuroscience 2023Quote: ... Animals were injected into their foot with 3-5 µL of 10-5 M ELH using a 10 µL Nanofil syringe (World Precision Instruments) equipped with a 35-gauge needle ...
-
bioRxiv - Bioengineering 2023Quote: ... DV –4.5 mm) using a microinjection apparatus (10 µL Hamilton syringe #80308, UMP-3 syringe pump, and Micro4 controller; all from World Precision Instruments).
-
bioRxiv - Cell Biology 2020Quote: ... The resistance between the upper and lower surfaces of IEC monolayers was measured before (Day 4) and after 2 days of stimulation (Day 6) using an EVOM2 epithelial Volt/Ohm meter (World Precision Instruments, FL, USA). The resistance of IEC monolayers was corrected by subtracting the resistance of scaffolds without cells and normalized by multiplying the effective scaffold surface area to provide a trans-epithelial electrical resistance (TEER ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipette electrodes with a tip resistance between 4 and 6 MΩ were pulled from thin-walled borosilicate glass capillaries (World Precision Instruments, Sarasota, FL) using a P-97 Flaming/Brown Puller (Sutter Instruments ...
-
bioRxiv - Bioengineering 2022Quote: ... The needle was allowed to sit in place for approximately 5 min and 3-5 μL of viral vector was injected using a microsyringe pump (World Precision Instruments, UMP3) and pump controller (World Precision Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... filled with normal ACSF) using a DAM-80 amplifier (low filter, 1 Hz; high pass filter, 3 KHz; World Precision Instruments, Sarasota, FL). Mossy fiber-mediated fEPSP were evoked by weak electrical stimulations performed via a bipolar NiCh electrode (NI-0.7F ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral Injections were unilaterally or bilaterally delivered using a syringe (65458-01, Hamilton, USA) controlled by an ultra-micropump (UMP-3, World Precision Instruments, USA) at a rate of 0.1 µl/min (total volume of 0.6 µl for slice imaging and 0.4 µl for fiber photometry) ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the cells were injected at the position 2 mm to the right lateral bregma and 3 mm deep with a flow of 0.2 μL/min utilizing a 10 μL precision micro syringe (World Precision Instruments, Florida, USA) with a 34-gauge needle ...
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
bioRxiv - Cell Biology 2023Quote: TEER was measured at 7-day intervals from 7-28 days in ALI cultures using an Epithelial Tissue Voltohmmeter (EVOM2) and STX2 electrodes (World Precision Instruments, Sarasota, USA). The STX2 electrodes were equilibrated in D-PBS prior to measurement ...
-
bioRxiv - Neuroscience 2023Quote: ... 20 nl of the Cre-dependent helper virus was injected to the HDB (bilateral, n = 2; unilateral, n = 1) using a Nanoliter 2010 microinjection pump (World Precision Instruments). The injection coordinates were defined by a stereotaxic atlas (Paxinos and Franklin ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
Clemizole and Trazodone are Effective Antiseizure Treatments in a Zebrafish Model of STXBP1 DisorderbioRxiv - Neuroscience 2022Quote: ... gap-free local field potential recordings (LFP; 60 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3) filled with 2 mM NaCl internal solution (~1 μm tip diameter ...
-
bioRxiv - Neuroscience 2021Quote: ... gap-free local field potential recordings (LFP; 15 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3); ~ 1 μm tip diameter ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were subject to nano-electrospray ionization (nESI) in positive ion mode (at ∼2 kV) with a pulled nanospray tip (World Precision Instruments 1B100-3) prepared as detailed in (48) ...
-
bioRxiv - Bioengineering 2021Quote: ... New Jersey) and custom 3D-printed components was assembled around the animal to support a 3-axis micromanipulator (502600, World Precision Instruments, Sarasota, FL) and linear actuator (M-235.5DD ...
-
bioRxiv - Neuroscience 2023Quote: ... A circular piece of the skull (3 mm in diameter) centered over the injection was carefully cut out using a sharp drill (Ideal micro drill, World Precision Instruments, Berlin, Germany). The dura was removed with forceps and mild vacuum suction was used to slowly remove the cortex within the craniotomy ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... at least 3 days before the day of injection and the craniotomies were covered with silicone elastomer (Kwik-Cast, World Precision Instruments, FL, USA). Before injection ...
-
bioRxiv - Neuroscience 2019Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion and reduce spread up the infusion tract ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Freshly isolated PAs were cannulated with glass micropipettes (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments) bathed with 37 °C PSS (PSS0Caplus 1.6 mM CaCl2 and without EDTA ...
-
bioRxiv - Cell Biology 2020Quote: ... and stiff pulling pipette (WPI TW100-6) were used for stretching chromosomes ...
-
bioRxiv - Neuroscience 2020Quote: ... were applied with a glass pipette (2-3 μm diameter) positioned 20 to 30 μm away from the soma and connected to a picospritzer (World Precision Instruments, adjusted to ~2 psi). All electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Cell Biology 2020Quote: An easily bent force pipette (WPI TW100F-6), and stiff pulling pipette (WPI TW100-6 ...