Labshake search
Citations for World Precision Instruments :
101 - 150 of 485 citations for 4 5 5 5 Tetrafluoro 4 trifluoromethoxy pentan 2 one since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2020Quote: ... After punching a fluid port through the 5 mm thick Sylgard using 0.75 mm diameter biopsy punches (World Precision Instruments) the PDMS chip was bonded onto glass substrates using an 0.3 mbar ...
-
bioRxiv - Neuroscience 2022Quote: ... Pups were anesthetized under hypothermia and 5 pulses of 69 nL were injected into the V1 with a nanoliter injector (WPI). Four days later ...
-
bioRxiv - Biophysics 2021Quote: ... The tip of the pipette was cut to an opening diameter between 1~ 5 μm and bent to ~40° using a microforge (DMF1000, WPI).
-
bioRxiv - Neuroscience 2022Quote: ... electrolytic lesions were obtained by passing positive and negative current (20-25 uA) on each electrode contact for 5 s with a stimulus isolator (A365RC, WPI) while the animal was under isofluorane-induced anesthesia ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2024Quote: ... transfected slices were then transferred to the microscope chamber perfused with carbogen (95% O2 / 5% CO2)-bubbled recording aCSF maintained at approximately 30 - 34 °C by an in-line solution heater (WPI). The aCSF contained (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... AAV viral vectors mixed with FastGreen for visualization (ratio 1:5) were injected using a PicoSpritzer (Cat. num. PV820, WPI) through pulled (P-30 puller ...
-
bioRxiv - Neuroscience 2023Quote: ... Cells expressing YFP and with a soma diameter <25 µm were targeted for whole cell recording using pipettes (∼5 MΩ resistance) pulled from borosilicate glass (WPI).
-
bioRxiv - Neuroscience 2024Quote: ... square craniotomy (1-1-5 mm diameter) was made and covered with a coverslip (World Precision Instruments, coverslip No. 1) fitting the size of the bone removed ...
-
bioRxiv - Neuroscience 2024Quote: ... was slowly inserted into the brain and 0.5 to 1 µl of viral particles were injected into the hippocampus using a microinjection pump (50 nl/min, WPI). The injection needle was left in place for about 3 minutes and then slowly retracted ...
-
bioRxiv - Bioengineering 2024Quote: ... The skin incision was closed using absorbable (5-0 PDS) subcuticular sutures and topical tissue adhesive (GLUture, World Precision Instruments) was applied to the incision ...
-
bioRxiv - Neuroscience 2020Quote: ... 1 mm inner diameter borosilicate glass (WPI, 1B100F-4) was pulled with a multistep horizontal puller (P-1000 ...
-
bioRxiv - Physiology 2020Quote: ... glass capillaries (TW-150-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL) were pulled to desired shape using a Sutter Inst ...
-
bioRxiv - Neuroscience 2022Quote: ... using a microinjector pump (UltraMicroPump3-4, World Precision Instruments). The needle was lowered over 1 min and remained in place for 1 min before infusion ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings: Patch pipettes (4-6 MΩ; World Precision Instruments) were pulled on a P-1000 puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording electrodes (WPI; 4–6 MΩ open tip resistance) were filled with an internal solution consisting of (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were performed with microinjector-controlled (micro-4, WPI) syringe (nanofil syringe and Nanofil 33G BVLD Needle ...
-
bioRxiv - Developmental Biology 2024Quote: ... thin wall glass capillaries (World Precision Instruments, #TW100F-4) were pulled on a P-87 micropipette puller ...
-
bioRxiv - Neuroscience 2021Quote: ... Constant current stimuli (0.5 μA-5 mA) were applied using a high-voltage stimulus isolator (A365R, World Precision Instruments, Sarasota, FL). The evoked mono and polysynaptic IPSCs were recorded simultaneously in GCs and SGC pairs ...
-
bioRxiv - Systems Biology 2021Quote: ... 1 mM beta-glycerol phosphate and 5 mM of sodium orthovanadate) using a syringe pump (Aladdin AL-1000, World precision instruments). Livers and right kidneys were quickly removed and snap frozen in liquid nitrogen ...
-
bioRxiv - Neuroscience 2022Quote: ... was injected iontophoretically (0.8—1.0 μA positive current pulses with a 7 s-on/off cycle for 5 min using A365, World Precision Instruments). The coordinates of the injection were [AP −2.9 ...
-
bioRxiv - Bioengineering 2021Quote: ... The culture medium in the trachea lumen and within the chamber was refreshed via a syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and a programmable pump (flow rate ...
-
bioRxiv - Bioengineering 2021Quote: ... the culture medium within the inner space of the trachea was replaced with the fresh medium once a day using a programmable syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and the removed culture medium was collected in a waste reservoir ...
-
bioRxiv - Neuroscience 2023Quote: Intracortical injections were made at multiple sites (∼5-9 sites per cranial window, spaced 0.5-1 mm apart) using a microinjector (NanoFil, World Precision Instruments) fit with a 36G beveled needle (NF36BV-2 ...
-
bioRxiv - Bioengineering 2023Quote: ... Drugs were infused over 5 minutes intravenously via a tail vein catheter with an infusion pump (World Precision Instruments, Sarasota, FL). Focused ultrasound was applied after 2.5 minutes of drug infusion for 2.5 minutes (250 kHz ...
-
bioRxiv - Neuroscience 2024Quote: ... We used 3−5 MΩ glass patch pipettes (capillary tubing with 1.5/0.75 mm OD/ID-World Precision Instruments, Sarasota, FL) that were pulled on a P-97 Flaming/Brown type micropipette puller (Sutter Instrument Co. ...
-
The CB1 receptor interacts with cereblon and drives cereblon deficiency-associated memory shortfallsbioRxiv - Neuroscience 2023Quote: Adult mice (2 months-old) were anaesthetized with isoflurane (4%) and placed into a stereotaxic apparatus (World Precision Instruments, Sarasota, FL, US). Adeno-associated viral particles were injected with a Hamilton microsyringe (Sigma-Aldrich #HAM7635-01 ...
-
bioRxiv - Developmental Biology 2023Quote: ... Ventral longitudinal muscle 6 in abdominal segments 3 or 4 was impaled with two intracellular electrodes (1 mm outer diameter borosilicate capillaries; World Precision Instruments, 1B100F-4) of ∼15 MΩ resistance (3M KCl) ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Cell Biology 2021Quote: ... was injected into each hemisphere of the M1 motor cortex using a glass pipette (tip diameter 5∼8 mm) at a rate of 100 nl/min using a syringe pump (Micro4; World Precision Instruments). The injection site was standardized among animals by using stereotaxic coordinates (ML = ±1.50 ...
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2022Quote: ... rats were deeply anaesthetised with urethane and lesions were made at the tip of the tetrodes using a 30 μA unipolar current for 5 – 10 s (Stimulus Isolator, World Precision Instruments). Then ...
-
bioRxiv - Neuroscience 2022Quote: ... Neural signals were amplified (20,000 X) and filtered (300 Hz – 5 kHz) through an isolated amplifier (ISO-Dam 80, WPI, Sarasota, FL, USA). The microelectrode was manually guided into a cutaneous fascicle by delivering weak electrical pulses (0.2 ms ...
-
bioRxiv - Neuroscience 2022Quote: ... They were filled with a 1 M KCl solution using a MicroFil non-metallic syringe needle (MF 34G-5, World Precision Instruments); a few recordings were done with 3 M KCl (no particular change was noticed).
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 1 and 5 MΩ using a MF-200 microforge (World Precision Instruments). An agar bridge (1M KCl ...
-
bioRxiv - Cell Biology 2023Quote: ... Cells were incubated for 60 min in 5% CO2 at 37°C in suspension before adding to glass-bottom dishes (FluoroDish, FD35-100, World Precision Instruments) or 12-mm diameter coverslips (Fisherbrand 1254580 ...
-
bioRxiv - Neuroscience 2024Quote: All recordings were performed at 31–33°C with electrodes (3–5 MΏ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with one of two intracellular solutions (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were pulled from glass capillaries (1B150F-4, WPI) to have a ∼20 μm opening ...
-
bioRxiv - Cell Biology 2021Quote: ... A glass micropipette (#1B100-4, World Precision Instruments, Sarasota, USA) was forged to a diameter smaller than the average protoplast radius (∼2.5 µm) ...
-
bioRxiv - Physiology 2020Quote: ... Briefly, glass capillaries (TW-150-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2021Quote: ... Pulled glass capillaries were used for microinjection (WPI, TW100F-4). Rather than use the ‘inject’ function on the Femtojet ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Fire-polished borosilicate (1B150F-4, World Precision Instruments, FL, USA) patch pipettes were used with resistance of 1-3 MΩ ...
-
bioRxiv - Physiology 2021Quote: ... Non-filamented glass capillaries (1B100-4, World Precision Instruments, USA) were immersed into 99.9 % methanol for five minutes and dried out at room temperature ...
-
bioRxiv - Neuroscience 2020Quote: ... DV -0.4 cm) using a microinjector-controlled (micro-4, WPI) seringe (nanofil seringe and Nanofil 33G BVLD Needle ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses were injected using a glass micropipette (WPI, 1B120F-4) filled with mineral oil attached to Nanoliter Injector with SMARTouch Controller (WPI ...
-
bioRxiv - Neuroscience 2023Quote: ... Micropipettes pulled from borosilicate glass (1B150F-4, World Precision Instruments) were filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: Borosilicate capillary glass (World Precision Instruments, Cat. No. 1B150F-4) was pulled into a fine tip and then beveled to an angled point ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... from a borosilicate glass capillary (1B150F-4, World Precision Instruments) and backfilled with 1 mM copper sulfate (MilliporeSigma) ...
-
bioRxiv - Genetics 2023Quote: ... and borosilicate glass microcapillaries (World Precision Instruments, cat.no.1b100-4), prepared using a micropipette puller device (Sutter