Labshake search
Citations for World Precision Instruments :
101 - 150 of 176 citations for 3 3 Bromomethyl phenyl thiophene since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... were carried out with Nanofil 10 μL syringe and UMP-3 controller attached to it (World Precision Instruments, Inc.).
-
bioRxiv - Neuroscience 2022Quote: ... Electric signals from motor neuron axons in the tail were recorded using borosilicate pipettes (TW150-3, World Precision Instruments) pulled by a horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... Item# WE30030.5A5) with 2-3 µm diameter and 0.5 MΩ impedance connected to DAM50 Extracellular Amplifier (World Precision Instruments); data were acquired with Clampex 10.7 (Molecular Devices) ...
-
bioRxiv - Neuroscience 2023Quote: ... 1-3% maintenance) and body temperature was maintained at 37.5°C using a temperature controller (ATC2000, World Precision Instruments). Animals were dosed with slow-release buprenorphine (0.1mg/kg ...
-
bioRxiv - Neuroscience 2022Quote: ... 30–100nl of virus were injected at a rate of 3–5nl/s at two depths (0.7–0.85, and 0.9–1 mm ventral) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Neuroscience 2022Quote: ... Warner Instrument) attached to a 3 mm-diameter and 1.2 mm-high cannula (Microgroup INC) using KwikSil adhesive (WPI). The edge of the cannula was fixed to the skull with cyanoacrylate ...
-
bioRxiv - Neuroscience 2022Quote: ... ABRs were band-pass filtered (0.3–3 kHz, ×20,000 gain) using analog filters/amplifiers (ISO-80, World Precision Instruments, Sarasota ...
-
bioRxiv - Neuroscience 2022Quote: ... patch pipettes with a resistance of 3~5 MΩ were made from borosilicate glass (World Precision Instruments, Sarasota, FL) with a Sutter Instrument P-97 micropipette puller (Novato ...
-
bioRxiv - Physiology 2023Quote: ... a pressure pipette (OD 3–4 μm) attached to a micropressure system (model 900A; World Precision Instruments, Sarasota, FL) was inserted into an early proximal segment ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained from NAc shell MSNs using borosilicate glass pipettes (3-5 ΩM; WPI) filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... ABRs were amplified (10,000 times) and bandpass filtered (0.3 – 3 kHz) by an amplifier (ISO 80, World Precision Instruments), and digitized using the external audio card (48 kHz sampling rate) ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording electrodes (3–4 MΩ) were pulled from thin-walled borosillicate glass (TW150F-4; World Precision Instruments, Sarasota, FL) and filled with (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording glass electrode (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) was pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 20-30 nl/minute into the parenchyma ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were performed with low resistance (1–3 MΩ) glass pipettes (ID: 0.68 mm, OD: 1.2 mm, WPI, Sarasota, FL) filled with aCSF under current-clamp mode with I=0 configuration ...
-
bioRxiv - Neuroscience 2023Quote: ... 30–120 nl of virus were injected at a rate of 3 nl/s at two depths (0.1 mm and 0.2 mm ventral/below pia) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled to resistances of ∼3 MΩ from thin-walled glass capillaries (World Precision Instruments, Cat# 1B120F-4). Importantly ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2024Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 30-40 nl/min into the parenchyma ...
-
bioRxiv - Neuroscience 2024Quote: ... 2-3 injections of 300nL of virus were made using a beveled glass micropipette at a depth of ∼300 μm to target layer 2/3 of the cortex at a rate of 65 nl/min with a microsyringe pump (UMP3T-2, WPI). For imaging experiments ...
-
bioRxiv - Genetics 2020Quote: ... Glass needles for zebrafish eggs injections were prepared from glass capillary tubes with filament (ø1 mm × 90 mm) (WPI #1B100F-3) using a NARISHIGE dual-stage micropipette puller PC-10 machine ...
-
bioRxiv - Biophysics 2020Quote: ... were collected by centrifugation for 3 min at 180 RCF and seeded onto glass bottom dishes (fluorodish; #FD35100, WPI, FL, USA) in CO2-independent medium (#18045-054 ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2022Quote: ... The tip of the pipette was cut to an opening diameter of ∼3 μm and bent to ∼40° using a microforge (WPI, DMF1000). Tethers were pulled with a 4 µm diameter polystyrene bead (Spherotech #DIGP-40-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... We sealed the craniotomy with silicone gel (Dow DOWSIL 3-4680, sometimes called “artificial dura”) and a silicone sealant (WPI KwikCast). We also implanted a stainless steel pin elsewhere on the dorsal surface of the skull ...
-
bioRxiv - Developmental Biology 2024Quote: Erythrocytes were isolated from 3-dpf zebrafish embryos (wild-type and miR-144Δ/Δ) by dissecting their tail using sapphire blade (WPI) and collecting cells in the bleeding buffer (1X PBS containing 2% PBS and 5 mM EDTA) ...
-
bioRxiv - Neuroscience 2024Quote: ... Reference glass electrode and recording glass electrode were created by processing Standard Glass Capillaries (Cat # IB150F-3, World Precision Instruments, USA) with glass puller ...
-
bioRxiv - Neuroscience 2024Quote: ... We used 3−5 MΩ glass patch pipettes (capillary tubing with 1.5/0.75 mm OD/ID-World Precision Instruments, Sarasota, FL) that were pulled on a P-97 Flaming/Brown type micropipette puller (Sutter Instrument Co. ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Neuroscience 2022Quote: Mice were anesthetized with 3% isoflurane (Aerrane, Henry Schein) for 2 min and then transferred to the stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% and monitored the same way as described above for IHKA injection ...
-
bioRxiv - Neuroscience 2020Quote: Somatic whole cell patch clamp recordings of visually identified CA1 principal cells were performed after 16-23 DIV with microelectrodes (3-8 MΩ) prepared from borosilicate glass capillaries (1B150F-4 World Precision Instruments) using a Sutter P-1000 puller ...
-
bioRxiv - Neuroscience 2020Quote: ... The administration speed was held constant at 800 nL/min by an injection pump (World Precision Instruments, Inc., UMP 3-4, USA), and the time interval between each injection path was 5 min (43) ...
-
A novel neural stem cell-derived immunocompetent mouse model of glioblastoma for preclinical studiesbioRxiv - Cancer Biology 2020Quote: ... to the bregma and 3 mm deep at a flow of 0.2 μL/min using a 10-μL precision microsyringe (World Precision Instruments, Inc) with a 34G needle.
-
bioRxiv - Cell Biology 2021Quote: ... were resuspended in 2–3 mg/ml rat-tail collagen I in RM+ medium and seeded on 23-mm FluoroDish cell culture dishes (World Precision Instruments). The collagen with embedded cells was allowed to set at 37°C until collagen contraction was observed (∼30 min) ...
-
bioRxiv - Neuroscience 2020Quote: ... and temperature measurements with a digital thermometer (Fisher Traceable Type-K thermometer) with rodent rectal temperature probe (World Precision Instruments, RET-3). For experiments performed in a cold environment ...
-
bioRxiv - Cell Biology 2022Quote: Pre-warmed assay media (200 μl) was added to the apical surface of the cultures and TEER was measured using an EVOM-3 meter (World Precision Instruments).
-
bioRxiv - Pathology 2022Quote: ... The core body temperature was measured rectally with a Thermometer equipped with a RET-3 mouse rectal temperature probe (WPI, Sarasota, FL).
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2020Quote: ... The reference and recording glass electrodes (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) were pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Bioengineering 2020Quote: ... was injected to separate microfluidic channels in the fiber through tubing connected to a standard precision injection apparatus (100 nl/s, NanoFil Syringe and UMP-3 Syringe pump, World Precision Instruments) while the fiber probe was embedded in 0.6% agarose gel (see details of tubing connection in Multifunctional Neuro Probes Assembly).
-
bioRxiv - Neuroscience 2021Quote: ... 1μL of virus was injected in the dorsal hippocampus and 1μl of virus in the ventral hippocampus (either AAV-miR-499 or AAV-Control) over 3 min via a microinjection pump (World Precision Instruments). The infusion cannula was left in place for an additional 3 min thereafter to allow diffusion ...
-
bioRxiv - Neuroscience 2020Quote: ... Field stimulations (10 Hz*60 s and 30 Hz*3 s) were performed with an A385 current isolator and a SYS-A310 accupulser signal generator (World Precision Instruments). Glycolysis was inhibited with 2-DG [5 mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Extracellular field potentials from de CA1 pyramidal neurons were recorded using a borosilicate glass micropipette (1–3 MΩ; RRID:SCR_008593; World Precision Instruments, Sarasota, US) filled with aCSF positioned on the slice surface in the stratum radiatum of CA1 and connected to the headstage of an extracellular recording amplifier (NeuroLog System ...
-
bioRxiv - Neuroscience 2023Quote: ... A connection cable (Plastics One, model 335–340/3) was used to connect the electrodes to a stimulus isolator (WPI, model A365) and the stimulator (AMPI ...
-
bioRxiv - Neuroscience 2023Quote: ... at a rate of 100 nL/minute through a 31-gauge gastight Hamilton syringe attached to a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments) with a 10 minute waiting period prior to the removal of the needle ...
-
bioRxiv - Bioengineering 2023Quote: ... DV –4.5 mm) using a microinjection apparatus (10 µL Hamilton syringe #80308, UMP-3 syringe pump, and Micro4 controller; all from World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... Animals were injected into their foot with 3-5 µL of 10-5 M ELH using a 10 µL Nanofil syringe (World Precision Instruments) equipped with a 35-gauge needle ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purified dsRNA was diluted to 2,000 ng/μL and 3 μg of dsRNA were injected with a Nanoliter (WPI, Sarasota, FL, USA) to the body cavity via the metapleuron under the wing ...
-
bioRxiv - Neuroscience 2023Quote: ... Three circular glass coverslip (2 of 3 mm and one 4mm coverslips) was affixed with a clear silicone elastomer (Kwik-sil, World Precision Instruments). A custom 3D-printed stainless steel headpost was attached on the skull and the rest of exposed skull area and the edge of the cranial window were covered using a dental acrylic (C&B Metabond) ...
-
bioRxiv - Neuroscience 2024Quote: All recordings were performed at 31–33°C with electrodes (3–5 MΏ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with one of two intracellular solutions (in mM) ...