Citations for World Precision Instruments :
51 - 100 of 633 citations for 3 5 Diacetoxy 2 acetoxymethyl 6 phenethyl tetrahydro pyran 4 yl ester since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes with a resistance of 4-5 MΩ were pulled from borosilicate capillaries (WPI, USA) in a horizontal puller (P1000 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2024Quote: ... A recording pipette with a resistance of 3–6 MΩ was pulled from a borosilicate glass capillary (World Precision Instruments, Sarasota, FL) using a micropipette puller (Model P-97 ...
-
bioRxiv - Neuroscience 2021Quote: Low-resistance patch electrodes (3–4 MΩ) were pulled from filamented borosilicate patch electrodes (World Precision Instruments, USA) with a PC-100 micropipette puller (Narishige ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Neuroscience 2024Quote: ... was puffed locally at the surface of the slice near the recorded cell through a micropipette (4-6 MΩ tip resistance; 1 sec puff duration) with a pneumatic drug ejection system [PicoPump PV 820 (WPI, Germany)] in presence or absence of strychnine (10 µM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Muscle cells were subsequently patched using fire-polished borosilicate pipettes with a resistance of 4-6 MΩ (World Precision Instruments, USA). We recorded membrane currents and potentials in a whole-cell configuration using a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Biophysics 2023Quote: ... with resistances of 2-3.5 MΩ (Cat. #TW150F-4, World Precision Instruments, Sarasota, FL, USA). Voltage commands were applied with a MultiClamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Physiology 2021Quote: ... Reference electrodes (5-10 megaohms) were pulled using filamented capillaries (1B100F-4, World Precision Instruments, USA) and back-filled with 1 M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... 4~5 MΩ for whole-cell recording) were pulled from borosilicate capillary glass (World Precision Instruments) with a Stutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording electrodes were typically 3-5 MΩ size and were pulled from borosilicate glass (World Precision Instruments). The intracellular solution used had the following composition (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... The electrode tip was filled to 2-3 mm with K+ ionophore solution (IE190, World Precision Instruments) by capillary action ...
-
bioRxiv - Physiology 2023Quote: ... a pressure pipette (OD 3–4 μm) attached to a micropressure system (model 900A; World Precision Instruments, Sarasota, FL) was inserted into an early proximal segment ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch clamp was performed on interneurons from the lumbar segments using 2–4 MΩ glass electrodes pulled from glass capillary tubes (Item #TW150F-4, World Precision Instruments, Sarasota, FL, USA) with a Flaming-Brown P-97 (Sutter Instrument Company ...
-
bioRxiv - Neuroscience 2020Quote: ... were applied with a glass pipette (2-3 μm diameter) positioned 20 to 30 μm away from the soma and connected to a picospritzer (World Precision Instruments, adjusted to ~2 psi). All electrophysiological recordings were extracted using Clampfit (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-6 MΩ) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Cell Biology 2024Quote: ... Glass capillaries (6-inch length, OD 1.0 mm, without filament (WPI TW100-6)) were used to make Triton and reagent spray pipettes (program 27 ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained from NAc shell MSNs using borosilicate glass pipettes (3-5 ΩM; WPI) filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... patch pipettes with a resistance of 3~5 MΩ were made from borosilicate glass (World Precision Instruments, Sarasota, FL) with a Sutter Instrument P-97 micropipette puller (Novato ...
-
bioRxiv - Neuroscience 2020Quote: Test compounds were dissolved in aCSF and locally puff-applied with a patch pipette (4–6 MΩ) at low pressure (∼1 psi) controlled by a Pneumatic Picopump (PV821, World Precision Instruments, USA) for 20 to 90s ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled to resistances of ∼3 MΩ from thin-walled glass capillaries (World Precision Instruments, Cat# 1B120F-4). Importantly ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette consisted of 5 barrels in an H configuration (World Precision Instruments, catalogue no. 5B120F-4) with the tip broken to a diameter of 30–40 μm [37] ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
Treatment with furosemide indirectly increases inhibitory transmission in the developing hippocampusbioRxiv - Neuroscience 2023Quote: ... Recording pipetes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipete tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipette electrodes with a tip resistance between 4 and 6 MΩ were pulled from thin-walled borosilicate glass capillaries (World Precision Instruments, Sarasota, FL) using a P-97 Flaming/Brown Puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus solution (0.4-0.6 µL) was injected at a rate of 2 nL/s with a microinjection pump (either Neurostar NanoW or WPI NanoLiter 2010). The pipette was slowly withdrawn at least 10 minutes after the completion of the injection ...
-
bioRxiv - Cell Biology 2024Quote: ... Briefly 0.1 to 0.2 x 106 cells were seeded in 2 ml of medium in 6-well dishes or 3cm glass-bottomed microscope dishes (World Precision Instruments) or 0.04 x 106 cells were seeded in 300µl of medium in chambers of an 8-well microscopy slide (Ibidi ...
-
bioRxiv - Cell Biology 2024Quote: ... Briefly 0.1 to 0.2 x 106 cells were seeded in 2 ml of medium in 6-well dishes or 3cm glass- bottomed microscope dishes (World Precision Instruments) or 0.04 x 106 cells were seeded in 300µl of medium in chambers of an 8-well microscopy slide (Ibidi ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2023Quote: ... Item# WE30030.5A5) with 2-3 µm diameter and 0.5 MΩ impedance connected to DAM50 Extracellular Amplifier (World Precision Instruments); data were acquired with Clampex 10.7 (Molecular Devices) ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch electrodes (final resistance 2–4 MΩ) were pulled from borosilicate glass (World Precision Instruments, Sarasota, FL, USA). The intracellular solution contained (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 2-4 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2020Quote: Somatic whole cell patch clamp recordings of visually identified CA1 principal cells were performed after 16-23 DIV with microelectrodes (3-8 MΩ) prepared from borosilicate glass capillaries (1B150F-4 World Precision Instruments) using a Sutter P-1000 puller ...
-
bioRxiv - Neuroscience 2020Quote: ... The administration speed was held constant at 800 nL/min by an injection pump (World Precision Instruments, Inc., UMP 3-4, USA), and the time interval between each injection path was 5 min (43) ...
-
bioRxiv - Neuroscience 2024Quote: ... two circular glass coverslips (one of 3 mm diameter and one of 4 mm) were affixed with a clear silicone elastomer (Kwik-Sil, World Precision Instruments). An extra layer of dental acrylic (C&B Metabond ...
-
bioRxiv - Neuroscience 2024Quote: ... We used 3−5 MΩ glass patch pipettes (capillary tubing with 1.5/0.75 mm OD/ID-World Precision Instruments, Sarasota, FL) that were pulled on a P-97 Flaming/Brown type micropipette puller (Sutter Instrument Co. ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Neuroscience 2022Quote: ... glass pipettes (3-8 MΩ, 1B150F-3, World Precision Instruments) were pulled using a horizontal puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2024Quote: All recordings were performed at 31–33°C with electrodes (3–5 MΏ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with one of two intracellular solutions (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were obtained using low-resistance pipettes (2.2 - 5 MΩ) pulled from filamented borosilicate glass (World Precision Instruments, Cat #1B150F-4) with a flaming/brown micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (2-4 MΩ) were pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments) on a Sutter P-97 puller (Sutter Instruments Company ...
-
bioRxiv - Molecular Biology 2024Quote: ... The electrical resistance of cell monolayers was measured on day 4 (before stimulation) and day 7 (after 3 days of stimulation) using an EVOM2 epithelial Volt/ Ohm meter (World Precision Instruments, FL, USA). The resistance of cell monolayers was corrected by subtracting the resistance of wells without cells and normalized by multiplying by the effective well surface area to provide transepithelial electrical resistance (TEER ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Freshly isolated PAs were cannulated with glass micropipettes (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments) bathed with 37 °C PSS (PSS0Caplus 1.6 mM CaCl2 and without EDTA ...
-
bioRxiv - Neuroscience 2022Quote: Mice were anesthetized with 3% isoflurane (Aerrane, Henry Schein) for 2 min and then transferred to the stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% and monitored the same way as described above for IHKA injection ...