Labshake search
Citations for World Precision Instruments :
601 - 650 of 3820 citations since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Kwik-cast (World Precision Instruments) is applied to the burr hole ...
-
bioRxiv - Neuroscience 2024Quote: ... and further polished with a MF200 microforge (WPI) prior to filling with internal pipette solution (102 mM potassium gluconate ...
-
bioRxiv - Neuroscience 2024Quote: ... was lowered into the dorsal hippocampus (−1.8 mm DV relative to dura) and 50 nl was infused at a rate of 100 nl/min using a Nanoliter injector system (World Precision Instruments, USA). The capillary was left in place for 5 minutes after injection and then slowly retracted to prevent backflow ...
-
bioRxiv - Neuroscience 2024Quote: ... a 35G needle mounted to a 10 μl Nanofil syringe and driven by a UMPI perfusion pump (WPI) was advanced to the coordinates (in mm ...
-
bioRxiv - Neuroscience 2024Quote: ... The craniotomy was cleaned with a sterile solution and covered with silicone sealant (Kwik-Sil, World Precision Instruments). After several hours of recovery ...
-
bioRxiv - Neuroscience 2024Quote: ... The exposed area was covered with silicone gel (Dowsil) and Kwik Cast silicone (World Precision Instruments). We allowed animals a minimum of 3 hours of recovery before beginning recordings ...
-
bioRxiv - Neuroscience 2024Quote: ... fire-polished borosilicate glass capillaries with filament (World Precision Instruments, Sarasota, USA) using a P-1000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Local field-potential (LFP) activity was recorded using a patch pipette prepared from thin-borosilicate glass (1.5mmOD, 0.84mmID, World Precision Instruments, cat.no. 1B150F-4) pooled and fire-polished on a Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2024Quote: ... craniotomies were sealed with Kwik-Sil (World Precision Instruments; Sarasota, FL), the microdrive and one intraoral cannula (IOCs ...
-
bioRxiv - Neuroscience 2024Quote: ... 200 nL at each depth) using a Nanoliter 2010 injector (World Precision Instruments) with glass pipettes (20–30 µm diameter tip and beveled) ...
-
bioRxiv - Neuroscience 2024Quote: ... We applied a thin layer of transparent Metabond dental acrylic over both hemispheres to prevent inflammation and covered the exposed skull with a silicone elastomer (Kwik-Cast, World Precision Instruments).
-
bioRxiv - Neuroscience 2024Quote: ... viruses were injected through a pulled glass pipette at a rate of 50 nL/min using a UMP3 microsyringe pump (World Precision Instruments). Pipettes were slowly withdrawn (< 100 µm/s ...
-
bioRxiv - Neuroscience 2024Quote: ... 10 µL Nanofil Hamilton syringes (WPI) with 33 G beveled needles were used to intracranially infuse AAVs into the different brain areas of interest ...
-
bioRxiv - Neuroscience 2024Quote: ... or a removable silicone plug (Kwik-Cast, World Precision Instruments). audTRN coordinates ...
-
bioRxiv - Neuroscience 2024Quote: ... Viruses were delivered via a gauge needle for the specification of 10 µL controlled by an Ultra Micro Pump (160494 F10E, WPI). To allow the virus to spread ...
-
bioRxiv - Neuroscience 2024Quote: ... 33-gauge Nanofil syringe attached to UltraMicroPump (UMP3) with SYS-Micro4 Controller (World Precision Instruments). We counterbalanced our injections into either the left or right hemisphere ...
-
bioRxiv - Neuroscience 2024Quote: ... Recordings were made with glass patch pipettes (World Precision Instruments 1B150F-3) pulled to 2-10 MOhms using a Sutter P-1000 puller ...
-
bioRxiv - Neuroscience 2024Quote: ... Viruses were pressure injected using a Nanoject III (Drummond) or a Nanoliter 2020 Injector (WPI) through a glass pipette slowly lowered into the craniotomy ...
-
Antibodies targeting Crimean-Congo hemorrhagic fever virus GP38 limit vascular leak and viral spreadbioRxiv - Microbiology 2024Quote: ... Electrical resistance was measured at the indicated time points with an Epithelial Volt Ohm Meter (EVOM) in combination with a “chopstick” STX2 electrode (World Precision Instruments). Untreated cells and a chamber without cells were used as controls to calculate relative resistance values and subtract background ...
-
bioRxiv - Biophysics 2024Quote: ... transfected (or stable) cells were always plated on glass-bottom dishes (World Precision Instruments, FD35) coated with fibronectin (Sigma ...
-
bioRxiv - Neuroscience 2023Quote: ... Flow rate (100-150 nl/min) was regulated by a syringe pump (World Precision Instruments). Following virus injection ...
-
bioRxiv - Neuroscience 2023Quote: Nanopipettes were fabricated from quartz capillaries with filament (o.d. 1 mm, i.d. 0.5 mm, 10 cm length, World Precision Instruments QF100-50-10). The capillaries were transformed into nanopipettes using a laser puller (P2000 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Pulled glass capillaries (World Precision Instruments, USA) were filled with 3M KCl and the tips clipped with tweezers and checked for appropriate resistance between 0.5 and 5 MΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Filling and emptying of the nanopipettes was enabled by MicroFil syringe tips (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2023Quote: ... We prepared the needles for virus injection by pulling glass pipettes (World Precision Instruments, # 1B100-6) on a puller (Narishige International ...
-
bioRxiv - Neuroscience 2023Quote: ... An automatic injection pump (World Precision Instruments) was used to control the speed at 200 nl/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus or tracer was then delivered into the target region of interest in pups or adults through a glass capillary by using a nanoinjector (World Precision Instruments). For fiber photometry experiments in adults ...
-
bioRxiv - Neuroscience 2023Quote: ... Viruses were delivered into brains through a glass capillary using nanoinjector (World Precision Instruments, Nanoliter 2000).
-
bioRxiv - Neuroscience 2023Quote: Electrodes were pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) using a P97 Flaming/Brown puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... The sterile manipulator and microinjector syringe pump (World Precision Instruments; Sarasota, FL) were attached to the cross bar of the stabilizing device (Figure 1A) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-6 MΩ) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2023Quote: ... Surgical silicone adhesive (kwik-sil, World Precision Instruments, USA) and quick adhesive cement (C&B Metabond ...
-
bioRxiv - Neuroscience 2023Quote: ... connected to a stimulus isolator (A365RC, WPI, UK) was positioned in L4 of the somatosensory cortex ...
-
bioRxiv - Neuroscience 2023Quote: A bipolar stimulation electrode (TM33CCNON; World Precision Instruments, Sarasota, FL, USA) connected to a stimulus isolator (A365RC ...
-
bioRxiv - Neuroscience 2023Quote: ... were injected in the ventral horn with a 33-gauge needle on a microsyringe controlled by an UltraMicroPump and Micro4 Microsyringe Pump Controller (World Precision Instruments, Sarasota, FL, USA). A total of six injections were performed bilaterally from C4 to C6 ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were pulled from borosilicate glass capillaries (Cat#: TW150-4F, World Precision Instruments) and coated with dental wax ...
-
bioRxiv - Neuroscience 2023Quote: ... The craniotomy was sealed with KwikSil silicone (WPI) before the stereotrode was anchored to the head-bar apparatus with dental cement ...
-
bioRxiv - Neuroscience 2023Quote: ... 1010 gc AAV8 in 1-2 μl was stereotactically injected with 15 nl/sec using a microinjection system (Nanoliter 2010, WPI) at (X ...
-
bioRxiv - Neuroscience 2023Quote: ... The lens was covered with removable Kwik-Cast (World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... A non-bioreactive silicone polymer (Kwik-Sil, World Precision Instruments) was used to fix the lens in place ...
-
bioRxiv - Neuroscience 2023Quote: ... the top of the GRIN lens was protected by a cut-off tip of an Eppendorf tube (Fisher) and secured using Kwik-Cast (WPI). The mice were allowed to recover from surgery for at least 2 weeks before any behavioral experiments.
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus was injected via a pulled needle of a borosilicate glass capillary (ID: 0.68mm, OD: 1.2mm; Kwik-fill, World Precision Instruments Inc., # 1B150F-4) that was angled at 50° to the slice using a stereotactic micromanipulator (SM-11 ...
-
bioRxiv - Neuroscience 2023Quote: ... we used a digitally controlled infusion system (UltraMicroPump, UMP3, and Micro4 Controller, WPI, USA) fed with a 10 μl Hamilton syringe and NanoFil (35 GA ...
-
bioRxiv - Neuroscience 2023Quote: ... in the Ntrs1-Cre line (150 μs, 0.1 Hz, glass pipette electrode, and WPI A365 stimulus isolator) at holding potentials of -70 and +40 mV ...
-
bioRxiv - Neuroscience 2023Quote: ... 0.3μl of the virus was injected by a 10μl microinjector (World Precision Instruments). The craniotomy hole was plugged by bone wax and the skin was sutured ...
-
bioRxiv - Neuroscience 2023Quote: ... with an attached 10-μL NanoFil syringe (World Precision Instruments) fitted with a 33-gauge NanoFil blunted tip (World Precision Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... 1474) and a 75-200 nL volume of viral vector was injected using a microinjector pump (World Precision Instruments, UMP3T-2) with an attached 10-μL NanoFil syringe (World Precision Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Micropipettes pulled from borosilicate glass (1B150F-4, World Precision Instruments) were filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... fitted with a 33-gauge NanoFil blunted tip (World Precision Instruments, NF33BL). The following coordinates were used (AP from bregma ...