Labshake search
Citations for World Precision Instruments :
551 - 600 of 725 citations for 6 Hydrazino 1 2 4 triazolo 4 3 b pyridazine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... Recordings from GPe neurons were obtained using micropipettes (2–4MΩ) made from 1.5 mm OD/1.12 mm ID borosilicate glass with a filament (World Precision Instruments, Sarasota, FL) pulled with a P-97 puller (Sutter Instruments Novato ...
-
bioRxiv - Neuroscience 2024Quote: ... which was achieved by passing 1 ms current pulses between the platinum-iridium electrodes of the stimulating chamber (Warner Instruments, PH-2) that were induced using a stimulus isolator (WPI, MODEL A382) whose output was controlled by the same custom Arduino-based circuit coupling imaging and stimulation ...
-
bioRxiv - Neuroscience 2019Quote: ... A bipolar tungsten electrode (1 MΩ, WPI) was positioned in the Schaffer collaterals emanating from the CA3 region of the hippocampus ...
-
bioRxiv - Neuroscience 2020Quote: ... with a 33-G beveled needle that was mounted into a motorized microinjector (Legato130, KD Scientific or UMP3T-2, WPI, Sarasota, FL, USA). Other surgical procedures and viral injection was as described previously (15).
-
bioRxiv - Neuroscience 2020Quote: ... at a rate of 0.2 μL/min with a glass micropipette connected to a Hamilton syringe controlled by stereotaxic syringe holder (SYS-Micro4, WPI, Sarasota, FL, USA). The needle was removed 10 min later ...
-
bioRxiv - Molecular Biology 2023Quote: The trans-epithelial electric resistance (TEER) was tracked using the EVOM voltohmmeter equipped with STX-2 chopstick electrodes (World Precision Instruments, Stevenage, UK) during wet (days −3 ...
-
bioRxiv - Neuroscience 2023Quote: ... fluoxetine was intracranially delivered with a volume of 58.7 nl/side over 2 min using a motorized single pressure syringe pump (World Precision Instruments, Sarasota, FL). After infusion ...
-
bioRxiv - Cancer Biology 2023Quote: ... a custom-made EEG adapter with attached wires (2 recording channels, one reference, each made from Teflon-coated silver (WPI, Sarasota, FL, USA) wire with ∼0.5mm tips exposed ...
-
bioRxiv - Bioengineering 2023Quote: ... Pupils were dilated and sub-retinal injections of 2 µL were performed using a Nanofil syringe with a 28-gauge blunt needle (World Precision Instruments, Inc.) under an operating microscope (Leica Microsystems ...
-
bioRxiv - Cell Biology 2021Quote: ... Transendothelial electrical resistance (TER) was measured daily using an EVOM volt ohm meter equipped with STX-2 electrodes (World Precision Instruments, Sarasota, FL, USA) and electrical resistance calculated as previously described (Bartosova et al. ...
-
Validating Minimally Invasive Laser Doppler Flowmetry for Serial Bone Perfusion Measurements in MicebioRxiv - Bioengineering 2019Quote: ... was placed directly on the exposed bone surface (Fig. 2) and held in place using a micromanipulator (MM3-ALL, World Precision Instruments, Sarasota, FL) to reduce signal noise from probe movement ...
-
bioRxiv - Neuroscience 2020Quote: Extracellular single-unit recordings confined to superficial cerebellar cortical layers were obtained in the awake animal during the reaching task using either parylene-insulated tungsten microelectrodes (WPI, impedance 2-5 MΩ) or a 16 channel Vector Array microelectrode (Neuronexus ...
-
bioRxiv - Neuroscience 2021Quote: ... The pipette was filled from the back end with mineral oil and attached to a syringe needle mounted in a microinjection syringe pump (World Precision Instruments, UMP3T-2). Before injection ...
-
bioRxiv - Neuroscience 2022Quote: ... with a Gamry 600+ potentiostat (Gamry Instruments, Warminster, PA) (N=2 arrays) using previously published methods89.Silver ground and reference wires (AGT05100, World Precision Instruments, Sarasota, FL) were soldered to the PCB ...
-
bioRxiv - Neuroscience 2024Quote: ... the stock solution was further diluted to 0.6 mM with saline and 2 µl of the diluted solution was intracerebroventricularly administered after the control recording sessions using a NANOFIL micro-syringe (World Precision Instruments; FL, U.S.A.) and ultra-micro pomp (UMP3T-1 ...
-
bioRxiv - Neuroscience 2023Quote: ... Infusions were made at a rate of 100 nL/min utilizing 29 Ga microinjection needles connected to FEP tubing secured to a 2 µl Hamilton syringe and a microinjection pump (UMP3, World Precision Instruments, Sarasota, FL). The infusion system was filled with distilled water and separated from the infused virus or drug by a small air bubble ...
-
bioRxiv - Neuroscience 2023Quote: ... the vagus nerve was mechanically stabilized on the micro-cuff electrode by applying a drop of 2-component silicone (Kwik-Sil, World Precision Instruments, Sarasota, FL) and then sectioned either caudal or rostral to the cuff ...
-
bioRxiv - Neuroscience 2020Quote: ... Tungsten macroelectrodes (<1 MΩ World Precision Instruments, USA) were used to record the local field potential and the evoked potential in the PeF (coordinates from Bregma ...
-
bioRxiv - Neuroscience 2021Quote: ... Tungsten macroelectrodes (<1 MΩ World Precision Instruments, USA) were used to record the local field potential and the evoked potential in the PeF (coordinates from Bregma ...
-
bioRxiv - Microbiology 2022Quote: Consumption of O2 was measured using an ISO-OXY-2 O2 sensor attached to an APOLLO 4000 free radical analyzer (World Precision Instruments, Inc., Sarasota, FL) as described52 ...
-
bioRxiv - Neuroscience 2023Quote: ... The space between the edges of the foil and the head capsule of the fly was sealed with 2-component silicon (Kwik-Sil™, World Precision Instruments, Sarasota, USA). A droplet of Ringer’s solution (NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus (AAV1/2-OXTp-hM4Dgi-mCherry or AAV1/2-OXTp-Venus or AAV1/2-OXTp-mCherry) was loaded into a 20μl NanoFil syringe fitted with a 33gauge needle (cat no. NF33BL, World Precision Instruments Inc, Sarasota, FL, USA). A final volume of 270nl was injected into the PVH (A-P −1.7mm ...
-
bioRxiv - Developmental Biology 2019Quote: ... They were then dechorinated and embedded laterally in 1% low gelling agarose in a 1-inch glass bottom cell culture dish (Fluordish, World Precision instruments). Real-time imaging was conducted at 28°C using a Nikon C2+ confocal microscope and a 20x (0.95NA ...
-
bioRxiv - Neuroscience 2022Quote: ... APs were evoked with platinum-iridium electrodes generating 1 ms pulses of 10 V cm-1 field potentials via a current stimulus isolator (A385, World Precision Instruments). For physin-GCaMP and vGpH ...
-
bioRxiv - Biochemistry 2023Quote: ... were evoked with platinum-iridium electrodes generating 1 msec pulses of an electric field of 10 V cm−1 via a current stimulus isolator (A385, World Precision Instruments). Laser power at the back aperture was ∼0.32 mW for 637 nm and ∼0.52 mW for 488 nm ...
-
bioRxiv - Neuroscience 2019Quote: ... blood pressure (pressure monitor BP-1; World Precision Instruments) and end expiratory CO2 (Capnograph type 340 ...
-
bioRxiv - Neuroscience 2021Quote: ... A Micro-1 microsyringe pump controller (World Precision Instruments) was used to inject 1.5 μl of virus at a constant rate over 10 minutes ...
-
bioRxiv - Neuroscience 2024Quote: ... and ultra-micro pomp (UMP3T-1, World Precision Instruments) at a flow rate of 10 nl/s ...
-
bioRxiv - Biophysics 2021Quote: ... to block or enhance a specific pathway the ear surface was gently cleaned and dried and a 4 µl solution containing a selected drug (Table 2) diluted in a PBS was microinjected in the earlobe skin using a 10 µl NANOFIL syringe (World Precision Instruments Inc., Sarasota, FL, USA) equipped with a gauge 33 needle ...
-
bioRxiv - Neuroscience 2019Quote: ... 100-150 nl of virus was injected at 1 nl/s with a microinjection syringe pump (UMP3T-1, World Precision Instruments, Sarasota, FL). Following injection ...
-
bioRxiv - Neuroscience 2019Quote: ... and blood pressure (Pressure Monitor BP-1; World Precision Instruments). Arterial blood gases were repeatedly measured (PO2 ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording pipettes were fabricated from 1-mm borosilicate glass (WPI), with tip resistances of 6–8 MΩ ...
-
bioRxiv - Neuroscience 2022Quote: ... using a microinjection syringe pump (UMP3T-1, World Precision Instruments). The pipette tip was left in place for 10min after each infusion before being slowly retracted ...
-
bioRxiv - Neuroscience 2024Quote: ... was located over the primary motor cortex (based on stereotactic coordinates at 0.2 mm anterior to bregma and 1.2 mm lateral to midline) and marked with a pen to be carefully removed and replaced by a precut #1 square cover glass (World Precision Instruments, coverslip No. 1). Cyanoacrylate-based glue and dental cement were used to seal the edges of the cover glass ...
-
bioRxiv - Neuroscience 2024Quote: Stage V-VI oocytes were injected (UMP3T-1, World Precision Instruments) at the equator with 50 nl cRNA mix containing the CaV2.2 complex hα1B ...
-
bioRxiv - Neuroscience 2021Quote: ... which was mounted on a MicroSyringe Pump (UMP3-1, World Precision Instruments) and controlled by a SYSMicro4 Controller (World Precision Instruments) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch-clamp recordings were performed using 1 mm diameter glass micropipettes (WPI) pulled (Sutter P1000 ...
-
bioRxiv - Neuroscience 2019Quote: Electrodes were prepared daily by the following procedure: 1) borosilicate glass capillaries (WPI) pulled on a Narishige PC-10 puller (∼5 megaohms ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with ∼1% agarose and protected with a silicone elastomer (Kwik-Cast, WPI). After the experiments ...
-
bioRxiv - Neuroscience 2021Quote: ... A 30-gauge Hamilton syringe coupled to a UMP3T-1 pump (WPI, USA) was used to inject 4 µl of Aβo or Aβsc (infusion rate = 0.5 µl/min ...
-
bioRxiv - Neuroscience 2022Quote: ... controlled by a microsyringe pump with SMARTouch Controller (UMP3T-1, World Precision Instruments) over ten minutes ...
-
bioRxiv - Neuroscience 2024Quote: ... the recording electrodes (made of borosilicate glass capillary drawn, 1 MΩ, PG10165, WPI) were placed in the stratum radiatum of the dorsal CA1 area of the hippocampus ...
-
bioRxiv - Neuroscience 2023Quote: ... 1 ms electric pulse generated by a stimulus isolator (World Precision Instruments, A365) was delivered onto the unit’s receptive field by a concentric bipolar electrode (World Precision Instruments ...
-
bioRxiv - Physiology 2020Quote: ... 1 μM peptide solution was infused with a syringe pump (World Precision Instruments, LLC.) into the buffer ...
-
bioRxiv - Physiology 2019Quote: Extracellular microelectrodes were made from filamented capillary tubes (1 mm diameter; World Precision Instruments) pulled to a tip resistance of approximately 5-7 mΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... the craniotomy and the Ag/AgCl ground pellet (1 × 2.5 mm, World Precision Instruments) were then submerged in a 2 % agarose (in saline ...
-
bioRxiv - Neuroscience 2020Quote: Patch-clamp recording pipettes were fabricated from 1 mm inner diameter borosilicate glass (WPI). Pipettes were pulled with a multistep horizontal puller (Sutter) ...
-
bioRxiv - Immunology 2020Quote: ... Amputation was performed with a 1 mm sapphire blade (World Precision Instruments, Friedberg, Germany) using a Leica M165C stereomicroscope and a micromanipulator (Leica Microsystems BV ...
-
bioRxiv - Systems Biology 2022Quote: ... 1 mm coronal slices collected using an acrylic brain matrix for mouse (World Precision Instruments) and the primary somatosensory cortex from three slices per brain (Fig ...
-
bioRxiv - Neuroscience 2021Quote: ... 1 mm coronal slices collected using an acrylic brain matrix for mouse (World Precision Instruments) and the regions of interest microdissected under a stereo microscope with a cooled platform ...