Labshake search
Citations for World Precision Instruments :
501 - 535 of 535 citations for 3RS 4 Dimethylamino 3 methyl 2 2 diphenylbutanenitrile Isodidiavalo since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
Prelimbic proBDNF facilitates memory destabilization by regulation of neuronal function in juvenilesbioRxiv - Neuroscience 2022Quote: ... which was arrayed into a 4×8 matrix using 25-μm-diameter tungsten wires (California Fine Wires) in a 35-gauge silica tube (World Precision Instruments). A cannula was attached to a silica tube ...
-
bioRxiv - Neuroscience 2023Quote: ... A total of 250 nL AAV was dispensed at each cortical layer through a glass-capillary-attached Hamilton syringe at a rate of 40 nL/min using a UltraMicroPump-4 system (World Precision Instruments). To image UDP in hippocampus ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5-inch-long needle attached to a 5 µl Hamilton syringe was mounted to the stereotaxic frame and controlled using a Micro 4 Microsyringe Pump (World Precision Instruments) to infuse 0.5 µl AAV2/PHP.eB-hGfaABC1D-DIO-hTDP43-WT (1.2 × 1013 particles/µl) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes for patch clamping were prepared freshly on the day of electrophysiology experiments from filamented glass capillaries (1B150F-4, World Precision Instruments) using a horizontal pipette puller (P1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV8 hSyn-DIO-hM3Dq-mCherry or AAV5 hSyn-DIO-mCherry was bilaterally injected into the PVH at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). The coordinates for injection into the supraoptic nucleus were as follows ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV serotype 9 OTp-mCherry was bilaterally injected into the PVH and the supraoptic nucleus at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments).
-
Dietary potassium and cold acclimation additively increase cold tolerance in Drosophila melanogasterbioRxiv - Physiology 2024Quote: ... The ion-selective microelectrodes used to measure hemolymph [K+] were fashioned from glass capillaries (TW150-4, World Precision Instruments, Sarasota, FL, USA) and pulled to a ∼ 1-3 mm tip on a Flaming-Brown micropipette puller (P-1000 ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were plated onto either 13 mm 1.5 glass coverslips in 4-well plates or FluoroDish 35 mm dishes ready coated with poly-D-lysine (PDL) (World Precision Instruments). Glass coverslips were coated with 0.1 ug/ul PDL for 20 minutes and washed once with F12 ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Physiology 2024Quote: ... using glass pulled microelectrodes filled with 3 M KCl (pipette resistance: 30–60 MΩ) connected to a DUO 773 electrometer (World Precision Instruments, Inc., FL, USA). For smooth muscle and endothelium recordings ...
-
bioRxiv - Biophysics 2020Quote: ... The signal from the force transducer was amplified using Transbridge TBM4M and digitized using Lab-Trax-4 data acquisition hardware (WPI, Sarasota, FL, USA). Three phases could be distinguished on force curves recorded using LabScribe v3 (iWorks ...
-
bioRxiv - Microbiology 2020Quote: The permeability of the differentiated epithelial layer (after 4 weeks of differentiation) was determined by measuring the TEER using an epithelial volt-ohm meter (EVOM2, World Precision Instruments, Inc.). The EVOM2 was calibrated according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2020Quote: Test compounds were dissolved in aCSF and locally puff-applied with a patch pipette (4–6 MΩ) at low pressure (∼1 psi) controlled by a Pneumatic Picopump (PV821, World Precision Instruments, USA) for 20 to 90s ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus was injected via a pulled needle of a borosilicate glass capillary (ID: 0.68mm, OD: 1.2mm; Kwik-fill, World Precision Instruments Inc., # 1B150F-4) that was angled at 50° to the slice using a stereotactic micromanipulator (SM-11 ...
-
bioRxiv - Neuroscience 2024Quote: ... Local field-potential (LFP) activity was recorded using a patch pipette prepared from thin-borosilicate glass (1.5mmOD, 0.84mmID, World Precision Instruments, cat.no. 1B150F-4) pooled and fire-polished on a Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2024Quote: Glass capillary tubes with an inner diameter about 0.2 mm were prepared from thin wall glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL), using puller (PC-100 ...
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2022Quote: ... A standard micropipette injection protocol was used to make all injections into the brain or spinal cord using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2020Quote: MC3T3-E1 Subclone 4 (ATCC® CRL-2593™) preosteoblastic cells were cultured on duplicate samples of tissue-cultured polystyrene (Fluorodish, World Precision Instruments) and commercially available argon-treated BC (CoArBC) ...
-
bioRxiv - Biophysics 2023Quote: ... A standard micropipette injection protocol was used to make all injections into the brain using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2024Quote: Molds for the device assembly were fabricated using PDMS and biopsy punches of 4 mm and 7 mm diameters (World Precision Instruments, Sarasota, FL). A large well was made in the PDMS with the 7 mm punch ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipette electrodes with a tip resistance between 4 and 6 MΩ were pulled from thin-walled borosilicate glass capillaries (World Precision Instruments, Sarasota, FL) using a P-97 Flaming/Brown Puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... A Hamilton syringe (Hamilton 7635-01) was filled with either PBS or C9-ASO at 50 ng/μL and attached to a microinjection pump (World Precision Instruments Micro 4) on a stereotactic arm ...
-
bioRxiv - Neuroscience 2023Quote: ... and 26-gauge needle (Hamilton) at a flow rate of 100 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Genetics 2023Quote: ... 0.5nl of the mixtures were directly injected into the yolk of freshly layed zygotes using a glass capillary needle [TW120-4) (Kwik-Fil, World Precision Instruments, Inc., Hertfordshire, UK)] with the help of a pedal controlled microinjector (PV820 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato, USA or 1B150F-4, World Precision Instruments, Sarasota, USA) in a horizontal pipette puller (P-1000 Micropipette puller ...
-
bioRxiv - Neuroscience 2024Quote: ... plasmid was delivered using a glass pipette at a flow rate of 50 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were obtained using tungsten electrodes (TM31C40KT, 4-MΩ impedance at 1 kHz or TM31A50KT, 5-MΩ impedance at 1 kHz; World Precision Instruments Inc., Sarasota FL, USA). All recordings were pre-amplified in the DC mode ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...