Labshake search
Citations for World Precision Instruments :
451 - 480 of 480 citations for tert Butyl 10 oxo 4 9 diazaspiro 4.5 decane 4 carboxylate since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: Viral injections were performed using a beveled 33-gauge microinjection needle connected to a 10 μL microsyringe (Nanofil; WPI, Sarasota, FL, USA) at a rate of 100 nL/min using a microsyringe pump (UMP3 ...
-
bioRxiv - Neuroscience 2023Quote: ... The viral vectors were injected using a 10 µl Hamilton syringe connected to a microinjector (UMP3 UltraMicroPump II with Micro4 Controller, World Precision Instruments). 0.8 µl of AAV was injected at a rate of 0.2 µl/min at two sites in each hemisphere ...
-
bioRxiv - Neuroscience 2024Quote: ... Viruses were pressure-injected using a 10-μl Hamilton syringe (model 1701 RN, Hamilton, Reno, UV) mounted on a motorized microinjector (UMP3T-2, WPI, Sarasota, FL) held by a manipulator (model 1460 ...
-
bioRxiv - Neuroscience 2024Quote: ... The viral vector was injected using a 10 µl Hamilton syringe connected to a microinjector (UMP3 UltraMicroPump II with Micro4 Controller, World Precision Instruments). 1 µl of AAV was injected at a rate of 0.2 µl/min at two sites in each hemisphere of IC ...
-
bioRxiv - Neuroscience 2024Quote: ... Each mouse was injected using the 10mL Hamilton syringe and 33g Hamilton needle aided by an infusion pump over 10 minutes (World Precision Instruments), with 10 minutes rest time after the infusion to allow the liquid to diffuse ...
-
bioRxiv - Neuroscience 2024Quote: ... Controlled injection of 200 nL virus at 80 nL/min rate was conducted using a NanoFil 10 μL syringe (World Precision Instruments) connected to an UltraMicroPump-3 (World Precision Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Injections were made using a Micro4 controller and UltraMicroPump along with 10 μl Nanofil syringes equipped with 35-gauge needles (WPI Inc., Sarasota, FL). Syringes were left in place for 10 min following injections to minimize diffusion ...
-
bioRxiv - Neuroscience 2020Quote: ... at a viral titer of 1.2 × 1011 using a Hamilton model 701 LT 10 μl syringe (#80301) and Neurostar glass capillary held together with microelectrode holder (World Precision Instruments #MPH6S10). Mice were anesthetized during the procedure with 3% isoflurane and received 15 mg/kg Meloxicam for pain relief ...
-
bioRxiv - Developmental Biology 2022Quote: 10 µl of the following drugs (in PBS) were injected intraperitoneally (IP) using a 100 µl Nanofil syringe (World Precision Instruments NANOFIL-100): blebbistatin 750 nM ...
-
bioRxiv - Neuroscience 2022Quote: ... relative to the Bregma using a drill and microinjection robot (Neurostar, Germany) with a 10 μl NanoFil syringe and 34Ga bevelled needle (World Precision Instruments, Germany). 950 nl of double-floxed inverted (DIO ...
-
bioRxiv - Genetics 2023Quote: ... Electrical signals generated by PN afferent endings were filtered (0.3 to 10 kHz) and amplified (x10,000) by a low-noise AC differential amplifier (DAM 80; World Precision Instruments, New Haven, CT). The signal was digitized at 20 kHz using a 1401 interface (Cambridge Electronic Design ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the cells were injected at the position 2 mm to the right lateral bregma and 3 mm deep with a flow of 0.2 μL/min utilizing a 10 μL precision micro syringe (World Precision Instruments, Florida, USA) with a 34-gauge needle ...
-
bioRxiv - Microbiology 2024Quote: ... A total of 10 μl of the cell suspension was then loaded into a 1mm diameter glass capillary needle (World Precision Instruments Inc.) by using a micro loader (Eppendorf AG) ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were made using a Micro4 controller and UltraMicroPump along with a 10 µl Nanofil syringes equipped with 33-gauge needles (WPI Inc., Sarasota, FL). The syringe was left in place for 10 minutes after injection to minimize diffusion ...
-
bioRxiv - Neuroscience 2021Quote: Extracellular signals were amplified at 100x gain and filtered through a 10-to 3000-Hz bandwidth filter on a DAM50 differential amplifier (World Precision Instruments, Sarasota, USA), with 50 Hz noise removed with a HumBug (Quest Scientific ...
-
bioRxiv - Neuroscience 2021Quote: ... in physiological saline containing 0.02% ascorbic acid or physiological saline (containing 0.02% ascorbic acid) was drawn into a 10 µL syringe with a 33 g needle (World Precision Instruments, Sarasota, FL, USA). 3 µL were infused into the medial forebrain bundle (coordinates ...
-
bioRxiv - Cell Biology 2022Quote: ... A block was then covered with an evenly spread layer of uncured PDMS (mixed at the base to cross-linking agent ratio of 10:1 (w/w)) and pressed against a No.1.5 glass-bottom dish (FD35-100, WPI Inc., Sarasota County, FL, USA). The dish with the negative mold was cured at 60°C for 2 hours to form the micropost topology on the glass surface.
-
bioRxiv - Neuroscience 2023Quote: ... Signals were amplified at 1000x gain and filtered through a 10 – 3000 Hz bandwidth filter using a DAM50 differential amplifier (World Precision Instruments, Sarasota, USA), with 50 Hz noise removed with a HumBug (Quest Scientific ...
-
bioRxiv - Neuroscience 2023Quote: ... Signals were amplified at 100x gain and filtered through a 10 – 3000 Hz bandwidth filter using a DAM50 differential amplifier (World Precision Instruments, Sarasota, USA), with 50 Hz noise removed with a HumBug (Quest Scientific ...
-
bioRxiv - Biophysics 2022Quote: ... The scutum mount was rigidly attached to a 10 N force transducer with a resonant frequency of 300 Hz (FORT1000, World Precision Instruments, Sarasota FL), and the posterior phragma mount was rigidly attached to the shaker head ...
-
bioRxiv - Cancer Biology 2024Quote: ... were inoculated 2.35 mm below the cortical surface using a 10 µL Hamilton syringe (Hamilton, Reno NV, USA) connected to an automatic push-pull microinjector (WPI SmartouchTM, Sarasota FL, USA), by advancing the 26G needle 3.85 mm from the surface of the skull (∼1mm skull-to-brain surface distance) ...
-
bioRxiv - Neuroscience 2024Quote: ... The AAV injection was done over 5 min using 10-μL Hamilton syringes (Hamilton, Reno, NV) driven by a microsyringe pump attached to an automated controller (World Precision Instruments, Sarasota, FL). On the same day as the intracranial injection ...
-
bioRxiv - Neuroscience 2024Quote: ... and transcardial perfusion with ice-cold 0.9% NaCl for 10 mins at a constant flow rate of 6mL/min using a peristaltic pump (World Precision Instruments, Sarasota, FL, USA). Brains were then sagittally bisected ...
-
bioRxiv - Neuroscience 2022Quote: ... The AAV suspension was infused bilaterally (1000 nl per hemisphere at a rate of 200 nl/min) using a NanoFil syringe (World Precision Instruments, NanoFil 10 ul) through a 33G beveled needle (World Precision Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... at a rate of 100 nl/min into the respective subareas using a 10 μl gas-tight Hamilton syringe (World Precision Instruments, Sarasota, FL, USA). To minimize the reflux of the injected volume ...
-
bioRxiv - Neuroscience 2021Quote: ... were bilaterally injected into the CeA by pressure injection with a Nanofil syringe (10 μl) attached to the infusion pump (MicroSyringe Pump, World Precision Instruments; 100 nl/min). At the end of the injection the needle remained in place for additional 5 min for proper diffusion of the solution ...
-
bioRxiv - Neuroscience 2021Quote: ... Kainate was injected at a rate of 70 nl/ min with a 10 µl Nanofil syringe (34 GA blunt needle, World Precision Instruments, Sarasota, FL, USA). The syringe was kept in place for 2 min after the injection was completed to avoid liquid reflux.
-
bioRxiv - Developmental Biology 2021Quote: Vivo-Morpholino solution was injected into the right side of quail mandibular primordia at HH18 with pulled glass micropipettes loaded into a PicoNozzle (5430-10) and a picospritzer fluid injector (PV830, World Precision Instruments, Sarasota, FL, USA). After injection ...
-
bioRxiv - Biophysics 2021Quote: ... to block or enhance a specific pathway the ear surface was gently cleaned and dried and a 4 µl solution containing a selected drug (Table 2) diluted in a PBS was microinjected in the earlobe skin using a 10 µl NANOFIL syringe (World Precision Instruments Inc., Sarasota, FL, USA) equipped with a gauge 33 needle ...
-
bioRxiv - Neuroscience 2024Quote: ... 5 HEPES) and connected to FEP tubing which was attached to a 10 µL Hamilton syringe in a syringe pump (World Precision Instruments Micro4 MicroSyringe Pump Controller). The recording pipette was backfilled with in vivo internal solution and advanced into the brain slowly using an MP-285 micromanipulator (Sutter Instruments) ...