Labshake search
Citations for Illumina :
1 - 50 of 1976 citations for 7 TRIFLUOROMETHYL 2 3 4 5 TETRAHYDRO 1H BENZO B AZEPINE HYDROCHLORIDE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... 4) DC3000 + B (Illumina only), 5 ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGGAAC TGCTGTTTCCCACTT-3’ for bait 2 (Illumina prefix appended to downstream primer). The bait sequences for the IRX3 proximal promoter were ...
-
bioRxiv - Cancer Biology 2024Quote: ... 5’-AATGATACGGCGACCACCGAGATCTACACTCTTT CCCTACACGACGCTCTTCCGATCTTGCAGGA GCCCGAAGCA-3’ for bait 2 (Illumina prefix appended to downstream primer) and ...
-
bioRxiv - Developmental Biology 2020Quote: ... Libraries were constructed with version 2 (stage 16a) or version 3 (stage15 a/b) chemistry and sequenced on a single HiSeqX (Illumina) lane to generate 400-450 million paired-end 150 bp reads (Supplementary Table 4).
-
bioRxiv - Microbiology 2023Quote: ... 4 μl of the 3’-5’-adapter-ligated RNA was mixed with barcoded RT primers (Illumina) and cDNA synthesis was performed using SuperScript™ II Reverse Transcriptase (Invitrogen ...
-
bioRxiv - Physiology 2021Quote: ... 3’ and 5’ adaptors (Illumina) were ligated and the resulting product was reverse transcribed to generate cDNA by PCR ...
-
bioRxiv - Biochemistry 2024Quote: Forward Illumina Adapter: 5’-ACACTCTTTCCCTACACGACGCTCTTCCGATCTXXXX-3’ Reverse Illumina Adapter: 5’-GACTGGAGTTCAGACGTGTGCTCTTCCGATCTXXXX-3’ Next generation (Illumina) sequencing was performed by Azenta (Amplicon-EZ) ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... we added four mate pair libraries (3 kb, 5 kb, 7 kb, 8 kb) prepared using a Nextera Mate Pair Library Prep kit (Illumina, San Diego, CA, USA). Each library was sequenced on an Illumina HiSeq 2500 sequencer by Novogene (Sacramento ...
-
Microplastic consumption induces inflammatory signatures in the colon and prolongs a viral arthritisbioRxiv - Immunology 2021Quote: ... for RNA extraction and 16S sequencing using V3-V4 region primers (Forward 5’- CCTAYGGGRBGCASCAG -3’ and Reverse 5’- GGACTACNNGGGTATCTAAT -3’. Sequencing was performed on an Illumina MiSeq platform.
-
bioRxiv - Developmental Biology 2022Quote: ... Extracted DNA was PCR-amplified (F 5’ – GTGCCTTCTCCGTCAGTCTC – 3’, R 5’ – GCAGGCACAAATCCAAGTTT – 3’, and subsequently subjected to next-generation sequencing in an Illumina MiSeq platform 116 ...
-
bioRxiv - Microbiology 2019Quote: ... the 16S rRNA sequences covering the V6-V7-V8 variable regions (5’ ACACTGACGACATGGTTCTACA 3’ and 5’ TACGGTAGCAGAGACTTGGTCT 3’) were PCR amplified and sequenced by Illumina MiSeq PE250 (paired-end) ...
-
bioRxiv - Microbiology 2020Quote: ... Microbiome communities in ligatures were characterized by sequencing of the 16S rRNA V1-V2 region using primers 8F 5’- AGAGTTTGATCMTGGCTCAG-3’ and 361R 5’- CYIACTGCTGCCTCCCGTAG-3’ which included the adapter for MiSeq sequencing (Illumina) and single end barcodes (4) ...
-
bioRxiv - Microbiology 2023Quote: The V3/V4 variable region of the 16S rRNA gene was amplified using primers 341F 5’CCTACGGGNGGCWGCAG′3 and 785R 5′GACTACHVGGGTATCTAATCC′3 (Klindworth et al., 2013 with Illumina Nextera XT overhang adapters for a dual-barcoding PCR library preparation approach ...
-
bioRxiv - Molecular Biology 2023Quote: ... for 1[h at 60°C and was subsequently PCR amplified using the primers 5′-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTC-3′ and 5′-CAAGCAGAAGACGGCATACGAGATJJJJJJGTGACTGGAGTTCAGACGTGTG-3′(where Js indicates the 6-mer index sequence for Illumina sequencing).
-
bioRxiv - Microbiology 2019Quote: 16S amplicon sequencing targeting the V3 and V4 variable regions of the 16S rRNA (341F: 5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 805R: 5’- GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATC C-3’) was performed on the Illumina MiSeq platform (Illumina, California, USA) according to manufacturer’s guidelines and generated paired-end reads of 300bp in each direction ...
-
bioRxiv - Microbiology 2019Quote: ... 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATC C-3’) were sequenced using the Illumina MiSeq 2 × 300 bp platform with MiSeq Reagent Kit v3 (Illumina Co.) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1.5 μl of PCR 1 were used as template for PCR 2 (14 cycles) and used forward primers 5’-AATGATACGGCGACCACCGAGATCTACAC-NNNNNNNN-ACACTCTTTCCCTACACGAC-3’ (compatible to Illumina i5) and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7) ...
-
bioRxiv - Microbiology 2023Quote: ... The V3-V4 region of the 16S ribosomal RNA gene was amplified by PCR with universal bacterial primer sets (5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATCC-3’) and was sequenced using MiSeq Reagent kit v3 (600 cycle) (Illumina Inc., California, US). The sequence data were analyzed using QIIME2 (https://qiime2.org/ ...
-
bioRxiv - Microbiology 2023Quote: ... 2 μl of the v1.5 sRNA 3’ adapter (Illumina) was mixed with the 14 μl eluate of the previous step in a 200 μl nuclease-free ...
-
bioRxiv - Genomics 2022Quote: ... and DRB3, 4, 5 (exon 2) genes with Fluidigm Access Array (Fluidigm, Singapore) and sequenced on an Illumina MiSeq sequencer (Illumina, San Diego, USA). HLA alleles and genotypes are called using the Omixon HLA Explore (version 2.0.0 ...
-
bioRxiv - Microbiology 2021Quote: ... 5 in treatment d28_0 and 5 from d28_100 (Illumina HiSeq, 2×150bp, GenoScreen, France). Reads corresponding to animal sequences were identified by aligning each dataset against Oryzias latipes available at the NCBI ...
-
bioRxiv - Microbiology 2020Quote: ... B) Informatics benchmarking (‘Experiment 2’) in which a seawater virome was sequenced with short-reads (Illumina) and long-read sequencing ...
-
bioRxiv - Microbiology 2023Quote: ... for each sample 2 μl of 5’ adapter (Illumina) (total 12 μl ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... Amplicons were calculated for their nano-molarity and diluted to 4 nM (see Illumina 470-2016-007-B) for HTS run on MiSeq sequencer using the Illumina MiSeq Reagent Kit Version 3 (600bp pair-ended) ...
-
bioRxiv - Molecular Biology 2022Quote: ... and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7), with both containing 8N barcodes for multiplexing.
-
bioRxiv - Cancer Biology 2022Quote: ... All of the 3′ and 5′ flowcells were demultiplexed with bcl2fastq (Illumina). FASTQ files were processed with Cell Ranger v7.0.1 (10x Genomics) ...
-
bioRxiv - Microbiology 2021Quote: ... The library was diluted to a final concentration of 7 pM and 5% of PhiX DNA (Illumina, USA) was added ...
-
bioRxiv - Genomics 2023Quote: ... 3) carried no SNP or indel within 50 bp in their 5’ or 3’ flanking regions (Illumina probe design requirement); and 4 ...
-
bioRxiv - Genomics 2019Quote: ... and with short reads using Pilon (two runs; Illumina library; Figure 1h).
-
bioRxiv - Microbiology 2020Quote: ... NGS sequencing was accomplished using MiSeq v.3 2×75 chemistry (Illumina). Raw sequencing files were demultiplexed using IlluminaBasecallsToFasq procedure from PICARD package and mapped to NC_055512.2 SARS-CoV-2 reference sequence with BwaAndMarkDuplicatesPipelineSpark procedure from GATK v.4.1.5.0 package (Broad Institute ...
-
bioRxiv - Microbiology 2023Quote: ... version 3 (2×300 bp read length; Illumina, San Diego, CA, USA).
-
bioRxiv - Microbiology 2022Quote: ... B provided by Illumina technical support ...
-
bioRxiv - Microbiology 2021Quote: ... 7) DC3000 − A (Illumina only), 8 ...
-
bioRxiv - Molecular Biology 2023Quote: ... 2 or 4 nM concentration and run on NextSeq 550 sequencer (Illumina) with NextSeq 500/550 High Output v2.5 (75 cycles PE ...
-
bioRxiv - Cancer Biology 2019Quote: ... Sequencing was performed on a HiSeq 2000 series for 2 × 100 paired end reads with a 7 nucleotide read for indexes using Cycle Sequencing v3 reagents (Illumina). All regions were covered by >200 reads.
-
bioRxiv - Microbiology 2021Quote: ... 8) DC3000 − B (Illumina only), 9 ...
-
bioRxiv - Genomics 2023Quote: ... The transposition reaction was incubated for 30 min or 1h at 37◦C (Illumina Tagment DNA Enzyme and Buffer kit ...
-
bioRxiv - Neuroscience 2023Quote: ... using the combination of primer Ad1_noMX (5’ AATGATACGGCGACCACCGAGATCTACACTCGTCGGCAGCGTCAGATGTG 3’) and the Nextera Index Kit (Illumina) primer N701-N706 ...
-
bioRxiv - Microbiology 2019Quote: ... and the primers V3F - 5’-CCTACGGGNGGCWGCAG-3’ and V4R – 5’-GACTACHVGGGTATCTAATCC-3’ [28] with the addition of the appropriate Illumina Nextera XT overhang adapter sequences (Illumina, San Diego, CA, USA). Following purification using a magnetic bead capture kit (Ampure ...
-
bioRxiv - Molecular Biology 2021Quote: ... libraries from amplicons 1–4 were mixed with 5% PhiX DNA control library (Illumina) and sequenced ...
-
bioRxiv - Genomics 2021Quote: ... then 4 pM of the pooled library with 5% PhiX v3 control (Illumina, USA) was loaded onto an Illumina MiSeq instrument and sequenced using MiSeq V3 chemistry ...
-
bioRxiv - Genomics 2021Quote: ... Libraries were generated from 2-5 μg of genomic DNA using the TruSeq 2 library preparation kit (Illumina, USA). Two types of libraries were prepared ...
-
bioRxiv - Genetics 2019Quote: ... The coding and splice-site regions of genes susceptible to hereditary arrhythmia and cardiomyopathies(10) were sequenced for probands II:3 and III-7 using Illumina HiSeq2500 Analyzer (Illumina, San Diego, CA, USA)(11) ...
-
bioRxiv - Genomics 2020Quote: ... using 5% PhiX without dark cycles (n = 11) or 10-20% PhiX with 7 dark cycles (protocol provided by Illumina, n = 49). A maximum of 12 samples were pooled in one sequencing run resulting in 19.05 million [17.05 – 21.72] single-end reads per sample on average (supplementary table 3).
-
bioRxiv - Cancer Biology 2021Quote: ... Libraries from 7 independent SCL-exo experiments were sequenced on 7 lanes of a HiSeq 1500 (Illumina) by the GEH facility (Rennes ...
-
bioRxiv - Immunology 2020Quote: ... The enriched B cell libraries were sequenced in NextSeq or MiSeq sequencer using NextSeq Mid Output v2.5 sequencing reagent kit (read length: 2 × 150 bp) or MiSeq Reagent Kit v2 (read length: 2 × 150 bp) (Illumina) respectively.
-
bioRxiv - Evolutionary Biology 2021Quote: Tn5ME-B (Illumina FC-121-1031), 59-GTCTCGTGGGCTCGGAGATGTGTA TAAGAGACAG-39
-
bioRxiv - Immunology 2021Quote: ... DRB3/4/5 kits) for sample library preparations and ran on a Miseq sequencer (Illumina), following the manufacturer’s instructions.
-
bioRxiv - Genetics 2019Quote: ... An average of 39.7 million 2 x 75 bp paired- end reads were generated for each sample on an Illumina NextSeq 500 (Illumina, Carlsbad, CA). FastQC was used to evaluate the quality of the reads ...
-
bioRxiv - Microbiology 2020Quote: ... The MiSeq Reagent Kit v.3 (2 x 300 bp) (Illumina Inc., San Diego, California USA) was used for sequencing according to manufacturer’s recommendations.