Labshake search
Citations for Illumina :
3901 - 3950 of 10000+ citations for Cow Putative Phospholipase B Like 2 PLBD2 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2022Quote: ... index sequences were added by PCR using Nextera XT index kit (Illumina, US). The amplicons were sent for sequencing with a paired-end read chemistry by a MiSeq sequencer (Illumina ...
-
bioRxiv - Microbiology 2022Quote: ... Metagenomic sequencing libraries were prepared using the Illumina DNA Prep Kit (Illumina, Inc.). Libraries from each plate were pooled in equal concentration (barring positive and negative controls ...
-
bioRxiv - Microbiology 2022Quote: ... DNA libraries were prepared using TruSeq Nano DNA kit (Illumina, FC-121-4002) using standard protocol with 8 PCR cycles ...
-
bioRxiv - Microbiology 2022Quote: ... spiked with 5% PhiX pre-made library from Illumina and loaded on a Miseq v3 kit (Illumina Inc., San Diego,CA,USA). Sequencing was performed for 1×150 cycles ...
-
bioRxiv - Microbiology 2022Quote: ... The cleaned library was quantitated using qPCR (NEBNext Library Quant Kit for Illumina), then pooled with PhiX ...
-
bioRxiv - Microbiology 2022Quote: ... Libraries were prepared by the TruSeq RNA Ribo-Zero kit (Illumina, CA, USA) and sequenced by Illumina novaseq 6000 with 100 bp paired-end reads.
-
bioRxiv - Systems Biology 2022Quote: ... rRNA was depleted using the Ribo-Zero Gold kit (Illumina, San Diego, CA) with 1 μg of total RNA as input for the SMARTer Apollo NGS library prep system (Takara ...
-
bioRxiv - Plant Biology 2022Quote: ... Sequencing libraries were prepared using the TruSeq Stranded mRNA Library Prep kit (Illumina), according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... RNA quality was checked by bioanalyzer and the TruSeq Stranded mRNA kit (Illumina) was used to prepare transcriptome libraries ...
-
bioRxiv - Neuroscience 2022Quote: ... RNA samples were prepped using TruSeq® Stranded mRNA Library kit (Illumina, 20020594). The resulting DNA libraries were sequenced according to the Illumina TruSeq Rapid v2 protocol on an Illumina HiSeq2500 sequencer ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... we used the TruSeq Stranded mRNA Library Prep Kit (Illumina, San Diego, CA). Briefly ...
-
bioRxiv - Neuroscience 2022Quote: ... Library preparation was performed using the Nextera XT DNA Library Preparation Kit (Illumina) with 600 pg input according to the Drop-seq protocol using Illumina i7 primers (N701—N706 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Ribosomal RNAs were depleted using Illumina Ribo-Zerp Plus rRNA Depletion kit (Illumina). Ribosomal-depleted RNA was then used for library preparation using NEBNext Ultra II Directional RNA Library Prep kit (NEW ENGLAND BioLabs ...
-
bioRxiv - Microbiology 2022Quote: ... Host ribosomal RNA (rRNA) was depleted with the Ribo-Zero Plus Kit (Illumina) and paired-end sequencing (150 bp ...
-
bioRxiv - Neuroscience 2023Quote: ... RNA-seq libraries were prepared using the TruSeq RNA Sample Preparation Kit (Illumina). All libraries were validated for concentration and fragment size using Agilent DNA1000 chips ...
-
bioRxiv - Neuroscience 2022Quote: ... Sequencing libraries were prepared using TruSeq© Stranded mRNA sample preparation kit (Illumina) and paired end 150-bp sequencing using Illumina HiSeq 2000 was performed by Novogene (Hong Kong) ...
-
bioRxiv - Neuroscience 2023Quote: ... cDNA libraries were prepared using a 3′-Tag-RNA-Seq library kit (Illumina). Sequencing was performed using one lane of a Hi-Seq 4000 platform with pair-end 40 bp reads ...
-
bioRxiv - Plant Biology 2023Quote: ... Then libraries were constructed using the Nextera XT DNA Sample Preparation Kit (Illumina) following manufacturer’s instructions.
-
bioRxiv - Physiology 2023Quote: ... The ribosome removal step was done using the RiboZero rRNA removal kit (Illumina). The sequencing was performed on Illumina HiSeq4000 sequencing system (∼30 million reads per sample ...
-
bioRxiv - Microbiology 2022Quote: ... Barcoded RNAseq libraries were then generated using the ScriptSeq™ v2 Kit (Illumina) per the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... RNA sequencing libraries were prepared using the TruSeq Stranded Total RNA Kit (Illumina) and quality checked by the Agilent Fragment Analyzer ...
-
bioRxiv - Molecular Biology 2022Quote: ... sequencing libraries were prepared using TruSeq Stranded Total RNA Library Prep Kit (Illumina). Sequencing was performed on Illumina HiSeq 2500 and > 150 million 100-nt reads were generated from each sample ...
-
bioRxiv - Plant Biology 2022Quote: ... sequencing libraries were constructed with a TruSeq Stranded mRNA Library Prep kit (Illumina) and sequenced on the NovaSeq 6000 platform (Illumina ...
-
bioRxiv - Microbiology 2022Quote: ... ribosomal RNA was removed from each sample using Ribo-Zero Plus kit (Illumina). The rest of the RNA was ligated to the RACE-seq adapter (see Table S2 ...
-
bioRxiv - Microbiology 2022Quote: ... Sequencing libraries were made using an Illumina DNA Prep Library Kit (Illumina, 20018705) in combination with IDT for Illumina DNA/RNA UD Indexes Set B ...
-
bioRxiv - Microbiology 2022Quote: ... provided in Nextera DNA Flex Library Prep Kit (Illumina, Inc., San Diego, CA), for barcode attachment (Supplemental Table 1) ...
-
bioRxiv - Molecular Biology 2022Quote: ... and 1.25 μM i5 and i7 PCR primers (Nextera® Index Kit (Illumina)) with the following PCR amplification conditions ...
-
bioRxiv - Molecular Biology 2022Quote: ... We prepared cDNA libraries using the TruSeq Stranded mRNA Library Prep Kit (Illumina) as described (24 ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... DNA libraries were prepared using the Nextera XT DNA Library Preparation Kit (Illumina) and IDT Unique Dual Indexes with total DNA input of 1ng ...
-
bioRxiv - Genetics 2022Quote: ... Sequencing libraries were constructed using Nextera XT DNA Library Preparation Kit (Illumina, USA), following the standard protocol ...
-
bioRxiv - Genomics 2022Quote: ... Libraries were then generated by TruSeq Nano DNA LT kit (Illumina, Cat#: 20015964) using TruSeq DNA Single Indexes (Illumina ...
-
bioRxiv - Plant Biology 2022Quote: ... Sequencing libraries were prepared using the TruSeq Stranded mRNA Library Prep kit (Illumina) following the manufacturer’s instructions and sequenced on a NovaSeq 6000 sequencer (Illumina).
-
bioRxiv - Cell Biology 2022Quote: ... library construction was completed with the Truseq Nano kit (Illumina; San Diego, CA) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2022Quote: ... The RNA-Seq library was generated by a TruSeq Stranded mRNA Kit (Illumina) and sequenced by HiSeq4000 (Illumina ...
-
bioRxiv - Neuroscience 2024Quote: ... followed by ribosomal RNA depletion using Ribo-Zero rRNA Removal Kit (Illumina; MRZH11124) according to the manufacturer’s protocol ...
-
bioRxiv - Physiology 2024Quote: ... Sequencing libraries were prepared using the TruSeq RNA Library Preparation Kit v2 (Illumina) following the low sample protocol ...
-
bioRxiv - Genomics 2024Quote: ... 0.01% digitonin) and 2.5μl of Tn5 from Nextera DNA Library Preparation Kit (Illumina) for 45-75min at 37°C in a thermomixer (500 RPM shaking) ...
-
bioRxiv - Plant Biology 2024Quote: ... RNA-Seq libraries were generated using the TruSeq stranded mRNA ligation kit (Illumina) from 1000-ng RNA samples ...
-
bioRxiv - Immunology 2024Quote: ... ATAC libraries were prepared using the Tagment DNA Enzyme and Buffer Kit (Illumina) following the Omni-ATAC protocol (18) ...
-
bioRxiv - Cancer Biology 2024Quote: ... RNA-seq libraries were prepared using TruSeq Small RNA Library Preparation Kits (Illumina) following the manufacturer’s protocol ...
-
bioRxiv - Immunology 2023Quote: ... followed by the Nextera® XT DNA Library Prep Kit (Illumina, California, USA). Final library quantity was measured using the KAPA SYBR® FAST qPCR and library quality evaluated using a TapeStation D1000 ScreenTape (Agilent Technologies ...
-
bioRxiv - Cancer Biology 2024Quote: ... Concentrations were normalized prior to tagmentation (Nextera Kit, Illumina Inc., San Diego, CA) and amplification of 3’ ends ...
-
bioRxiv - Immunology 2023Quote: ... Libraries were then prepared for sequencing with NovaSeq 600 Reagent Kits (Illumina; 20028400) and sequenced on Illumina NovaSeq 6000 (Ilumina ...
-
bioRxiv - Molecular Biology 2024Quote: ... and sequenced using an MiSeq Reagent Kit v3 (600-cycle format; Illumina Inc.) on an Illumina MiSeq sequencer (Illumina Inc. ...
-
bioRxiv - Microbiology 2023Quote: ... DNA libraries were prepared using a NexteraXT library preparation kit (Illumina, CA, USA). Samples were sequenced using an Illumina NextSeq with 150 bp paired-end reads ...
-
bioRxiv - Microbiology 2024Quote: ... Sequencing libraries were prepared using the Nextera XT library preparation kit (Illumina, Inc.). After indexing using a dual barcoding system according to the manufacturer’s protocol and then normalizing to a concentration of 4nM ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... Sequencing library preparation was done by using the DNA library preparation kit (Illumina). DNA sequencing was performed on Illumina Novaseq 6000 with 150 bp paired-end ...
-
bioRxiv - Cancer Biology 2024Quote: Whole exome sequencing (WES) was performed using the Nextera Exome Enrichment Kit (Illumina). 2 x 100 nucleotide paired end sequences were input into Illumina HisSeq2000 with an output of 100 nucleotide paired end reads in FASTQ format ...
-
bioRxiv - Immunology 2024Quote: ... and ribosomal RNA was depleted using Ribo-Zero Gold rRNA Removal Kit (Illumina) for all datasets except for the RNA-Seq analysis in naïve versus LI/LBT/L-activated splenocytes from WT mice (Fig ...
-
bioRxiv - Cell Biology 2023Quote: ... transposed DNA fragments were amplified using Nextera DNA Flex kit (#20018704, Illumina, Inc.). To reduce GC and size bias in PCR ...