Labshake search
Citations for Illumina :
301 - 350 of 9516 citations for Rat G Protein Coupled Bile Acid Receptor 1 GPBAR1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2023Quote: ... RNAseq libraries were prepared from total RNA with the QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina (Lexogen, 015.24) in combination with the UMI Second Strand Synthesis Module for QuantSeq FWD (Illumina, Read 1) (Lexogen ...
-
Dysregulated expanded endocannabinoid system as therapeutic targets of amyotrophic lateral sclerosisbioRxiv - Neuroscience 2024Quote: ... A library was independently prepared with 1 µg of total RNA for each sample by an Illumina TruSeq Stranded mRNA Sample Prep Kit (Illumina, Inc.). The first step in the workflow involved purifying the poly-A-containing mRNA molecules using poly-T-attached magnetic beads ...
-
bioRxiv - Microbiology 2024Quote: Libraries for Illumina short read sequencing were prepared from 1 ng of extracted DNA utilizing the Nextera XT DNA Library Prep Kit according to the manufacturer’s recommendations (Illumina Inc., USA). Sequencing was carried out in paired-end (2×300 base pairs ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Barcoded RNA-seq libraries were prepared from 1 μg of total RNA using the TruSeq Stranded mRNA Library Prep kit according to the manufacturer’s instructions (Illumina Inc., USA). RNA-seq libraries were sequenced on an Illumina NovaSeq 6000 System according to the manufacturer’s protocol ...
-
bioRxiv - Genomics 2020Quote: ... using the TruSeq SBS Kit v3-HS 200 cycles Kit (Illumina). The raw RNA-seq reads (available at GEO GSE137895 ...
-
BRD2 inhibition blocks SARS-CoV-2 infection by reducing transcription of the host cell receptor ACE2bioRxiv - Cell Biology 2021Quote: ... The kit employed was TruSeq RNA Library Prep Kit v2 (Illumina) over polyadenylated RNA and the manufacturer’s instructions were followed ...
-
bioRxiv - Molecular Biology 2021Quote: ... 1 ug of treated RNA was then input into the Illumina TruSeq Small RNA Library Preparation Kit (Illumina; Cat #: RS-200-0012) with 11 cycles of PCR amplification ...
-
bioRxiv - Genomics 2020Quote: ... Samples were prepared for sequencing using 1 ug of genomic DNA following the TruSeq PCR free kit protocol (Illumina, FC-121-3001). Resulting libraries were quality checked on an Agilent DNA 1000 bioanalyzer (Agilent Technologies ...
-
bioRxiv - Genomics 2019Quote: TruSeq libraries were prepared with 1 µg of total RNA using the TruSeq Stranded mRNA Library Prep Kit (Illumina, #RS-122-2101) and following the manufacturer's instructions ...
-
bioRxiv - Plant Biology 2020Quote: 42 RNA samples from experiment 1 were used for mRNA-Seq library preparation using the TruSeq Stranded mRNA Library Prep Kit (Illumina, CA, USA). Libraries were multiplexed and single-end 100 nt RNA-Seq was performed on a Novaseq 6000 at the GIGA Center (University of Liege ...
-
bioRxiv - Genomics 2022Quote: ... a library was prepared from 1 μg of genomic DNA and a TruSeq DNA PCR-free Sample Preparation Kit (Illumina, CA, USA). Paired-end (151 bp per read ...
-
bioRxiv - Genomics 2022Quote: ... Libraries were prepared with 1 μg of total RNA for each sample using a TruSeq Stranded mRNA Sample Prep Kit (Illumina, CA, USA). Paired-end sequencing (151 bp ...
-
bioRxiv - Cell Biology 2020Quote: ... cDNA was diluted 1:15 and subsequently tagmented and amplified for 12 cycles using the Nextera XT DNA Library Preparation Kit (Illumina FC-131). Individual libraries were QC’d by Qubit and Agilent Bioanalyzer ...
-
bioRxiv - Genetics 2020Quote: ... One sequencing experiment (Experiment 1) was performed according to the manufacturer’s directions for the TruSeq Small RNA Sample Preparation Kit (Illumina, RS-200-0012). The protocol was adapted to incorporate a 2S blocking DNA oligo for removal of prevalent Drosophila small ribosomal RNA from the sequencing library [67] ...
-
bioRxiv - Genomics 2020Quote: ... The cDNA library was generated from 1 µg of total RNA using TruSeq RNA Sample Prep Kit (Illumina, San Diego, CA, USA) following manufacturer’s protocols ...
-
bioRxiv - Immunology 2020Quote: ... The Illumina RNA-seq cDNA library was prepared using 1 μg of RNA from each sample and TruSeq V2 kits (Illumina, CA, USA), with reduced RNA fragmentation time (3 minutes ...
-
bioRxiv - Plant Biology 2021Quote: ... Libraries for RNA-Seq were prepared from 1 µg of total RNAs with the TruSeq Stranded mRNA Library Prep Kit (Illumina, CA, USA), multiplexed and sequenced in two runs with an Illumina NextSeq500 device (high throughput mode ...
-
bioRxiv - Immunology 2022Quote: ... Amplified (1 ng) cDNA was used to generate barcoded libraries using the Nextera XT DNA library preparation kit (Illumina, San Diego, CA). The size of the libraries was checked using the Agilent 2100 Bioanalyzer High Sensitivity DNA chip and their concentration was determined using the Qubit® fluorometer (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1 µg of total RNA was used as input for the TruSeq RNA Library Prep Kit v2 (Illumina, Inc., San Diego, CA) and the manufacturer’s protocol was followed ...
-
bioRxiv - Genomics 2024Quote: DNA concentration was normalized to 1 ng/μl and subjected to library preparation using Nextera XT DNA Library Preparation Kit (Illumina, CA, USA) according to the manufacturer’s instructions and sequenced with NextSeq550 using Mid Output Kit v2.5 (300 cycles ...
-
bioRxiv - Genomics 2023Quote: 1 ng of genomic DNA from each sample was used with Illumina MiSeq Nextera XT DNA Library Preparation Kit (Illumina, Inc., USA), the paired-end library was constructed with an insert (500 bp ...
-
bioRxiv - Immunology 2023Quote: ... and sequencing was performed in a 1×100 bp single-read format using a NovaSeq 6000 v1.5 100-cycle reagent kit (Illumina, Cat no. 20028316). Base calling was performed with Illumina Real Time Analysis (RTA ...
-
bioRxiv - Genomics 2023Quote: ... Libraries were prepared using the QuantSeq 3’ mRNA-Seq Library Prep Kit FWD for Illumina and UMI Second Strand Synthesis Module for QuantSeq FWD (Illumina, Read 1) from Lexogen (015.96 and 081.96 ...
-
bioRxiv - Genomics 2022Quote: ... we generated a combination of noisy ONT sequencing (MinION R.9.4.1 flow cells with the LSK-109 ligation library prep kit) and Illumina sequencing (PE 150 bp, ∼49x coverage; Illumina NovaSeq 6000). Based on published ONT benchmarking (https://nanoporetech.com/accuracy) ...
-
bioRxiv - Genomics 2024Quote: ... Total RNA-seq libraries were generated from 1 μg of DNase-treated RNA using the TruSeq Stranded total RNA library preparation kit (Illumina, Cat# 15031048) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2024Quote: Indexed sequencing libraries were generated from 1 ng genomic DNA using Nextera XT DNA Library Preparation Kit (Illumina, San Diego, CA, USA) following the protocol of the manufacturer ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... in the pair-end mode using HiSeq Rapid Pair-end Cluster Kit v2 and HiSeq Rapid SBS Kit v2 500 cycle kit (Illumina) reagents ...
-
bioRxiv - Immunology 2020Quote: ... using 2 × 300 bp paired-end kits (Illumina MiSeq Reagent Kit v3). Sequence analysis and assembly of lineage trees were performed using an in-house custom analysis pipeline as previously described (39 ...
-
bioRxiv - Cancer Biology 2022Quote: ... and HiSeq SBS Kit V4 50 cycle kit (FC-401-4002, Illumina). NovaSeq 6000 paired-end sequencing was performed using 54 cycles for Read 1 ...
-
bioRxiv - Genomics 2019Quote: ... with the flags -m 2 and -g to remove homopolymeric guanine repeats at the end of the reads (a systematic error of Illumina NovaSeq 6000).
-
bioRxiv - Cell Biology 2020Quote: ... v2 Kit (Illumina Inc.). Illumina novaSeq base call (BCL ...
-
bioRxiv - Cell Biology 2019Quote: ... v2 Kit (Illumina Inc.). Approximately 44*106 reads were obtained for each sample ...
-
bioRxiv - Genomics 2019Quote: Three kits from Illumina were tested with different total RNA input ...
-
bioRxiv - Microbiology 2019Quote: ... Nextera XT kit (Illumina) was used for library preparation and 2 × 150 bp paired-end sequencing was conducted on a MiSeq platform (Illumina ...
-
bioRxiv - Immunology 2021Quote: ... and SBS kits (Illumina). Target read depths were ∼5-10 million raw reads per sample.
-
bioRxiv - Microbiology 2019Quote: ... and index kit (Illumina). Library validation was performed on a 2100 Bioanalyzer (Agilent Technologies ...
-
bioRxiv - Microbiology 2022Quote: ... Ligation kit (Illumina, Inc.) according to the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2024Quote: ... v2 Kit (Illumina Inc.), resulting in high-quality reads ranging from 11 to 17 million reads per sample (Table S3 ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... ligation kit (Illumina, 20040532) according to the manufacturer’s instruction from 35 ng of RNA (except for macaque replicate_2 ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... or nano kits (Illumina) depending of the DNA yield of the siolation process in any case using a more conservative 350bp insert size ...
-
bioRxiv - Cancer Biology 2023Quote: ... (M) Tagmentation Kit (Illumina) according to the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2023Quote: ... Ligation kit (Illumina, Inc.) according to the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2024Quote: ... Tagmentation Kit (Illumina, USA) following the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2024Quote: ... Ligation kit (Illumina, Inc.) according to the manufacturer’s protocol ...
-
bioRxiv - Molecular Biology 2023Quote: ... and cell surface protein libraries were sequenced on the NextSeq 550 System (Illumina).
-
bioRxiv - Genomics 2021Quote: ... Library preparation was carried out with the Nextera XT DNA Sample Preparation Kit and MiSeq Reagent Kit V2 Library Preparation Kit (Illumina Inc.). DNA was sequenced with Illumina MiSeq technology ...
-
bioRxiv - Cancer Biology 2020Quote: ... 500 ng alkylated RNA was used and prepared with a commercially available kit (QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina and PCR Add-on Kit for Illumina, Lexogen). Sequencing was performed on an Illumina NovaSeq SP platform in 100bp-single-read mode.
-
bioRxiv - Plant Biology 2023Quote: ... from 100 to 1000 ng of total RNA using a stranded kit (Illumina TruSeq Stranded Total RNA Kit or NEB Next Ultra™ II Directional RNA Library Prep Kit for Illumina). The resulting data files contained paired end sequences (150 bp ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... A paired-end library was constructed from 1 µg of the DNA using TruSeq DNA PCR-Free LT Sample Prep kits (Illumina K.K., Tokyo, Japan) following the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2020Quote: ... libraries were prepared from 1 ng of cDNA using the Nextera® XT DNA Library Preparation Kit (Illumina Inc., San Diego, CA USA) according to the manufacturer’s instructions ...