Labshake search
Citations for Illumina :
301 - 329 of 329 citations for 5 SULFOPICOLINIC ACID since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2020Quote: ... PCR amplification and index incorporation were performed in a 50 μl reaction containing 5 μl of forward and reverse index primers (Illumina Nextera Index Kit), 15 μl NPM ...
-
bioRxiv - Genomics 2020Quote: ... Individual cells were sequenced to a mean depth of ~1.5 million 38 bp paired-end reads on an Illumina NextSeq 500 instrument with 75 cycle high output kits (Illumina TG-160-2005).
-
bioRxiv - Genomics 2022Quote: ... and DRB3, 4, 5 (exon 2) genes with Fluidigm Access Array (Fluidigm, Singapore) and sequenced on an Illumina MiSeq sequencer (Illumina, San Diego, USA). HLA alleles and genotypes are called using the Omixon HLA Explore (version 2.0.0 ...
-
bioRxiv - Microbiology 2024Quote: Total RNA of 5 μg was used to construct strand-specific RNA-sequencing libraries using the TruSeq RNA sample preparation Kit from Illumina (San Diego, CA). Briefly ...
-
bioRxiv - Genomics 2023Quote: ... about 1.5 ng purified pre-amplified cDNA sample was fragmented in four 20 μl tagmentation mix (10 μl 2x TD buffer, 5 μl Nextera XT (Illumina, FC-131-1096), and 5 μl cDNA sample ...
-
bioRxiv - Cell Biology 2024Quote: ... library was generated for 10 plasma exosome samples (n=5, young and old individuals each) using a propriety Illumina Truseq™ Small RNA Preparation kit (Illumina, # RS-930), according to the manufacturers’ guide ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... DNA solutions of approximately ≥5 ng μL−1 were subjected to the tagmentation reaction using the Nextera DNA Flex Library Prep Kit (Illumina, San Diego, CA) was used at 1/40 scale of the provided protocol ...
-
bioRxiv - Genomics 2020Quote: ... The pool was denatured with sodium hydroxide according to Illumina recommendation and spiked with 5% PhiX (PhiX control v3 Illumina Catalogue FC-110-3001) before loading (Fig 1).
-
bioRxiv - Cancer Biology 2019Quote: ... To this end shotgun libraries were generated from 5-10ng of plasma DNA using the TruSeq DNA Nano Sample Preparation Kit (Illumina, San Diego, CA, USA) as previously described[35] ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... we added four mate pair libraries (3 kb, 5 kb, 7 kb, 8 kb) prepared using a Nextera Mate Pair Library Prep kit (Illumina, San Diego, CA, USA). Each library was sequenced on an Illumina HiSeq 2500 sequencer by Novogene (Sacramento ...
-
bioRxiv - Genomics 2019Quote: ... A mate pair library with an insert size of 5 kb was created with the Nextera Mate Pair Sample Prep Kit (Illumina, San Diego, CA, USA). The paired-end and mate pair libraries were sequenced on an Illumina MiSeq machine ...
-
bioRxiv - Microbiology 2020Quote: ... One nanogram of quantified DNA was sheared enzymatically at 55°C for 5 min using the Illumina Nextera XT tagmentation enzyme (Illumina, San Diego, CA, USA). Tagmented DNA fragments were enriched by 10 cycles of PCR amplification using PCR master mix and primers with the index from Illumina ...
-
bioRxiv - Genomics 2020Quote: Small RNA libraries were prepared starting from 5 µL DNase treated and spike-in supplemented RNA eluate using a TruSeq Small RNA Library Prep Kit (Illumina, San Diego, CA, USA) according to the manufacturer’s protocol with two minor modifications(1) ...
-
bioRxiv - Microbiology 2019Quote: ... and the primers V3F - 5’-CCTACGGGNGGCWGCAG-3’ and V4R – 5’-GACTACHVGGGTATCTAATCC-3’ [28] with the addition of the appropriate Illumina Nextera XT overhang adapter sequences (Illumina, San Diego, CA, USA). Following purification using a magnetic bead capture kit (Ampure ...
-
bioRxiv - Plant Biology 2020Quote: ... on Thermo Fisher Scientific’s Quantstudio 5 before multiplex pooling (13-16 samples per lane in equal representation) and sequencing on the NextSeq500 platform (Illumina, San Diego, California, USA) paired-end 2×150 bp High Output.
-
bioRxiv - Genomics 2021Quote: ... and four mate-pair sequencing libraries (insert sizes of 2, 5, 10, and 15 kb) in accordance with manufacturer protocols (Illumina, San Diego, CA, USA). Libraries were then sequenced using a HiSeq2000 instrument (Illumina) ...
-
bioRxiv - Immunology 2021Quote: ... The V(D)J enriched library was then constructed via Chromium Single Cell 5’ Library Construction Kit (10x Genomics Cat#1000020) and libraries were sequenced in a NovaSeq™ 6000 Sequencing System (Illumina, San Diego, CA). V(D)J sequences were collapsed using Cell Ranger ...
-
bioRxiv - Genomics 2020Quote: ... Each pool (2nM per library; Agilent SureSelect XT HS, n=6; Agilent SureSelect XT RNA Direct, n=6; Illumina TruSeq RNA Exome, n=5) was sequenced on one lane on the Illumina HiSeq 3000 platform in the Technology Center for Genomics and Bioinformatics at UCLA ...
-
bioRxiv - Microbiology 2024Quote: ... and diluted to 5 pM prior to sequencing on an Illumina MiSeq platform with a 2 × 250 bp paired-end protocol (Illumina, San Diego, CA, USA). Sequencing reads were deposited in the European Nucleotide Archive (ENA ...
-
bioRxiv - Developmental Biology 2024Quote: ... Pooled libraries with unique 5′ and 3′ index adapter pairs were sequenced on an NextSeq 2000 P3 flow cell (Illumina®: San Diego, CA) to generate 66M (±12M ...
-
bioRxiv - Developmental Biology 2022Quote: Raw reads were subjected to adapter and quality trimming with cutadapt (version 2.4; parameters: --quality-cutoff 20 --overlap 5 --minimum-length 25; Illumina TruSeq adapter clipped from both reads) followed by trimming of 10 nucleotides from the 5’ and 3’ end of both reads ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... Approximately 5 ug of total RNAs were used to construct cDNA libraries (NEBNext Ultra Directional RNA Library Prep Kit for Illumina, Illumina, San Diego, CA, USA). Transcriptome sequencing was performed using the Illumina Hi-Seq 2000 platform ...
-
bioRxiv - Neuroscience 2022Quote: Total RNAs from cultured mouse WT and CD38 KO astrocytes at 5 DIV were used for RNA library preparation using TruSeq Stranded mRNA Sample Preparation Kit (Illumina, Inc., San Diego, CA, USA), with polyA selection for ribosomal RNA depletion.
-
bioRxiv - Genetics 2020Quote: ... Illumina adapters were incorporated onto the 5’ end of each primer for the attachment of Nextera XT Illumina indices (Illumina, Inc., San Diego, CA, USA) in the second round of PCR ...
-
bioRxiv - Genetics 2022Quote: ... of the parental and the F1 fish were based on whole-genome sequencing of the parents (5– 10X coverage; Illumina Hiseq platforms, BGI Hong Kong) and DarTseq (Diversity Arrays Technology ...
-
bioRxiv - Systems Biology 2020Quote: ... Supernatants were discarded and nuclei were re-suspended in 50 μl reaction buffer (2.5 μl of Tn5 transposase and 25 μl of TD buffer from a Nextera DNA Library Prep Kit from Illumina, and 22.5 μl nuclease-free H2O). The reaction was incubated at 37°C for 30 min ...
-
bioRxiv - Molecular Biology 2020Quote: ... the NEBNext Ultra II DNA Library Preparation kit was used to generate libraries using 5-10 ng of input or immunoprecipitated DNA and barcode adaptors (NEBNext Multiplex Oligos for Illumina (Set 1, E7335 and Set 2, E7500)) ...
-
bioRxiv - Genomics 2024Quote: ... bidentatus DNA extraction and library preparation was performed by Dovetail Genomics (Scotts Valley, CA, USA) with the TruSeq DNA PCR-Free kit (Trueq Index 5, Illumina, San Diego, CA, USA, mean size 475bp). 150 bp paired-end sequencing was performed on one lane of HiSeqX by Novogene (Cambridge ...
-
bioRxiv - Developmental Biology 2024Quote: ... we prepared n=40 sequencing libraries from 1µg total RNA per sample using Illumina® Stranded mRNA Prep kits with unique 5′ and 3′ index adapter pairs (IDT for Illumina® RNA UD Indexes, Set A). Libraries were PCR amplified for 10 cycles ...