Labshake search
Citations for Illumina :
251 - 300 of 836 citations for 3 Cyclohex 1 enyl acrylic acid methyl ester since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... and 3’ mRNA sequencing libraries were generated according to manufacturer’s recommendations (Lexogen, 015-QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina and 020-PCR Add-on Kit for Illumina). Samples were analyzed on an Illumina HiSeqV4 SR50 platform by the NGS Facility at Vienna BioCenter Core Facilities (VBCF) ...
-
bioRxiv - Immunology 2024Quote: ... Single-cell RNA libraries were prepared according to the 10x Genomics Chromium Single Cell 3′ Reagent Kits v2 User Guide and sequenced on a NovaSeq 6000 (Illumina).
-
bioRxiv - Microbiology 2024Quote: ... The RNA was dephosphorylated in 3’ and then phosphorylated in 5’ to generate cDNA libraries using the NebNext Small RNA Sample Prep kit with 3’ sRNA Adapter (Illumina) according to the manufacturer’s protocol with 12 cycles of PCR amplification in the last step followed by DNA purification with Monarch PCR DNA cleanup kit (NEB) ...
-
bioRxiv - Pathology 2024Quote: ... 5’- GTC TCG TGG GCT CGG AGA TGT GTA TAA GAG ACA GGG ACT ACH VGG GTW TCT AAT-3’ (italicized sequence is the Illumina adapter following by barcode ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... and mate-pair libraries of 3-kb insert size were prepared using the Nextera Mate Pair Sample Preparation Kit (cat. No. FC-132-1001, Illumina). We performed DNA shearing for the fragment and mate-pair library preparations using Covaris S220 ...
-
bioRxiv - Genomics 2024Quote: ... Sequencing was performed using a molarity of 62.4 nM and 3% PhiX spike in on the Nova Seq 6000 with SP flow cell kit and 200 cycles (Illumina).
-
bioRxiv - Genomics 2024Quote: ... Pooled samples were sent to Admera Health and sequenced on a NovaSeq S4 (one pool with 40 samples) or NovaSeq X Plus (3 pools with 18-19 samples) platform (Illumina) using 150 bp paired-end reads.
-
bioRxiv - Cancer Biology 2024Quote: ... Library generation for 10x Chromium analysis was performed following the Chromium Single Cell 3′ Reagents Kits (10x Genomics) and sequenced on an Hiseq4000 (Illumina), to achieve an average of ∼44,000 reads per cell and ∼11,000 cells per sample ...
-
bioRxiv - Cancer Biology 2024Quote: ... H146 and H69) and 3 NSCLC lines (H838, H1944 and A549) was subjected to methylation analysis using the Infinium MethylationEPIC BeadChips (Illumina) allowing the simultaneous quantitative measurement of the methylation status at 865,918 CpG sites ...
-
bioRxiv - Cell Biology 2020Quote: ... an oligonucleotide containing the Illumina P7 adaptor sequence was ligated to the 3’ end of the single stranded LAM PCR fragments using Circligase (Epicentre/Illumina, #CL9025K). A P5 adaptor was added by PCR ...
-
bioRxiv - Neuroscience 2020Quote: ... Sequencing libraries (1.3 nM) were chemically denatured and applied to an Illumina NovaSeq flow cell using the NovaSeq XP chemistry workflow (Illumina-20021664). Following transfer of the flowcell to an Illumina NovaSeq instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... The cell solutions were immediately transferred to ice and transported to the Wellcome Trust Centre for Human Genetics (WTCHG) for scRNAseq via 10x genomics chromium (10x genomics, US) (Single Cell 3’ v3) and Illumina hiseq 4000 (Illumina, US). This approach achieved 66-72K mean reads per cell and a sequencing depth of 53-55% per cell before filtering.
-
bioRxiv - Molecular Biology 2020Quote: ... RNA was extracted and sequence reads (100 bp paired-end) were generated with Illumina TruSeq high output version 3 chemistry on a HiSeq 2500 (Illumina, Inc.) at NRC-Plant Biotechnology Institute (NRC-PBI) ...
-
bioRxiv - Cancer Biology 2020Quote: ... TN5 tagmentation and library amplification realized 3’end fragments by Nextera XT DNA Sample Preparation Kit (Illumina, Cat#FC-131-1024) according to the manufacturer’s instructions while P5_TSO and Nextera_N7xx took the place of the custom primers ...
-
bioRxiv - Developmental Biology 2022Quote: ... 500 ng of total RNA were used as input for QuantSeq (QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina; Lexogen) following the autoQuantSeq automated workflow ...
-
bioRxiv - Neuroscience 2020Quote: ... Samples were processed according to the standard 10x Chromium 3’ workflow and pooled before sequencing over two lanes (Illumina HiSeq 4000).
-
bioRxiv - Cancer Biology 2020Quote: ... 500 ng alkylated RNA was used and prepared with a commercially available kit (QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina and PCR Add-on Kit for Illumina, Lexogen). Sequencing was performed on an Illumina NovaSeq SP platform in 100bp-single-read mode.
-
bioRxiv - Genomics 2021Quote: ... and ligated to custom CpG-free annealed adapters (Oligo 3 - Custom CpG-free P7 adapter and Oligo 4 - Custom CpG-free P5 adapter; annealed according to the standard Illumina protocol). The adapter-ligated gDNA was purified and amplified in 20 reactions using KAPA HiFi master mix (Roche ...
-
bioRxiv - Genomics 2021Quote: ... and 1µM Dexamethasone or 0.1% ethanol for 3 hours. Transposition was performed using the OmniATAC protocol (Corces et al. 2017) and the tagment DNA TDE1 enzyme (Illumina, 20034197). DNA was purified using the MinElute PCR purification kit (Qiagen) ...
-
bioRxiv - Cell Biology 2022Quote: The input samples were submitted to the Washington University Genome Technology Access Center to obtain and sequence the cDNA libraries (10XGenomics, 3’v3.1; Illumina NovaSeq S4) according to established protocols ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1.5 μl of PCR 1 were used as template for PCR 2 (14 cycles) and used forward primers 5’-AATGATACGGCGACCACCGAGATCTACAC-NNNNNNNN-ACACTCTTTCCCTACACGAC-3’ (compatible to Illumina i5) and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7) ...
-
bioRxiv - Immunology 2024Quote: ... 2024) using the command CreateSeuratObject with the following parameters: min.cells = 3 and either min.features = 200 (for Illumina reads from MBC gate) or min.features = 100 (for the Oxford Nanopore reads from the ASC gate) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1 x 105 mESCs and 5 x 104 S2 cells were resuspended in Tagment DNA Buffer and treated with 3 µL TDE1 Tagment DNA Enzyme (Illumina 20034197). After thorough mixing ...
-
bioRxiv - Genomics 2023Quote: For all tandem repeat identification and quantification we used DNA sequences from 2,504 individuals from the Phase 3 of the 1,000 Genomes Project (∼30x coverage Illumina short-read data) (Byrska-Bishop et al ...
-
bioRxiv - Genomics 2023Quote: ... 200ng alkylated RNA were used as input for generating 3’-end mRNA sequencing libraries using a commercially available kit (QuantSeq 3ʹ mRNA-Seq Library Prep Kit FWD for Illumina, Lexogen).
-
bioRxiv - Genomics 2024Quote: ... we further pooled the hybrid selection into 3 “super pools.” 2) The hybrid selected libraries were sequenced on a NovaSeq 6000 (Illumina, 20012850) with a S1 Reagent Kit v1.5 (200 cycles ...
-
bioRxiv - Cancer Biology 2024Quote: ... Collected single cells were placed on ice and further processed using the Chromium™ Single Cell 3’ Solution (10x Genomics) and sequenced on a NovaSeq 6000 (Illumina) with Illumina 3’ v3.1-paired end chemistry ...
-
bioRxiv - Cancer Biology 2024Quote: ... for 15 min at RT with 3 µl of the USER adaptor (NEBNext Multiplex Oligos for Illumina, NEB, cat. no. E7338A) for an additional 15 min at 37°C ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... we combined 3 μl of each sample (approx 2.24 ng) with a small quantity of a Nextera™ tagment DNA enzyme (Illumina catalogue #15027865). To decrease costs ...
-
bioRxiv - Microbiology 2021Quote: ... The libraries were sequenced using an Illumina MiSeq with MiSeq Reagent Kit v.3 (2x 300 bp, Illumina, San Diego, CA, USA) according to manufacturer’s instructions.
-
bioRxiv - Cell Biology 2022Quote: ... The quantitative 3-step real-time PCR was performed by the Eco Real-Time PCR system (Illumina Inc., San Diego CA, USA) and CFX Connect (Bio-Rad Laboratories AG ...
-
bioRxiv - Cancer Biology 2021Quote: ... RNA-seq libraries were constructed using a QuantSeq 3’mRNA-Seq Library Prep Kit (LEXOGEN, Vienna, Austria) and sequenced with the NextSeq500 (Illumina, CA, USA) to generate a minimum of two million single-end 75-bp reads ...
-
bioRxiv - Genomics 2021Quote: ... and Reverse primer (5’-GTC TCG TGG GCT CGG AGA TGT GTA TAA GAG ACA GGA CTA CHV GGG TAT CTA ATC C-3’) with Illumina sequencing adaptors (Illumina, California, USA). The purified PCR products were then subjected to a multiplexing process using Nextera XT Index kit (Illumina ...
-
bioRxiv - Genomics 2022Quote: ... all of the ChIP DNA and 220 ng of input DNA were mixed with 3 units of T4 DNA polymerase (NEBNext® DNA Library Prep Master Mix Set for Illumina, #E6040L) to create blunt ends ...
-
bioRxiv - Synthetic Biology 2024Quote: ... and a reverse primer annealing to the intronic region directly 3’ of the J segment (PCR1 Rev primer with Illumina adapter overhang). PCRs were performed with Q5 High-fidelity DNA polymerase (NEB ...
-
bioRxiv - Genomics 2023Quote: ... WGS of the samples of Batch 3 was commercially performed by Eurofins (Germany) using Genome Sequencer Illumina NovaSeq platform (Illumina, California, USA) (paired-end 150 bp reads).
-
bioRxiv - Developmental Biology 2024Quote: ... Single cell libraries were prepared by the University of Michigan Advanced Genomics Core and sequencing was performed using the 10X Genomics Chromium platform using manufacturer’s protocol for 10x Single Cell Expression 3’ and sequenced on the NovaSeq (S4) 300 cycle (Illumina, San Diego, CA). Sequencing outputs were demultiplexed using 10x Genomics Cell Ranger 7.1.0 software and FASTQ files were aligned to the Genome Reference Consortium Mouse Build 38 ...
-
bioRxiv - Molecular Biology 2024Quote: ... purified and ligated to 3′ and 5′ RNA adapters derived from TruSeq Small RNA Library Preparation Kit (Illumina, San Diego, CA, USA). Small RNA libraries were created using TruSeq Small RNA Library Preparation Kit (Illumina ...
-
bioRxiv - Pathology 2024Quote: ... Gene dosage of the SNCA locus on chromosome 4 was determined by inspecting the B allele frequency and LogR Ratio plots (Extended data suppl-Fig. 3) from Neurobooster array data (155 variants) using GenomeStudio (Illumina Inc., CA).
-
bioRxiv - Developmental Biology 2021Quote: ... RNA-seq libraries were generated using Illumina SureCell WTA 3’ Library Prep Kit for the ddSEQ System (6 cartridge version, cat.no. 20014280, Illumina, San Diego, CA, USA). Libraries were assessed for quality ...
-
bioRxiv - Genomics 2020Quote: ... and libraries were constructed by the Lexogen QuantSeq 3’ mRNA-Seq Library Kit FWD (Lexogen, Vienna, Austria).19 All RNA libraries were sequenced by the Illumina HiSeq4000 (Illumina, San Diego, CA). Raw sequencing data were aligned to the reference genome (GRCh37 ...
-
bioRxiv - Genetics 2021Quote: ... Libraries constructed with the Lexogen QuantSeq 3′ mRNA-Seq Library Kit FWD (Lexogen, Greenland, NH) were sequenced on an Illumina NextSeq 500 (Illumina, San Diego, CA) at the Genomics Facility of the Cornell Institute of Biotechnology.
-
bioRxiv - Evolutionary Biology 2021Quote: ... All three reactions were pooled in equal-molar ratios and sequenced (paired end 300 bp) on one lane of Illumina MiSeq version 3 chemistry (Illumina, San Diego, California). The final reaction comprising 21 libraries with DNA concentrations 11.4 – 20.0 ng/μl was performed and sequenced as above.
-
bioRxiv - Systems Biology 2021Quote: Single nuclear 3’ RNA-sequencing was performed at the Indiana University Center for Medical Genomics Core using the Chromium single cell system version 3 (10x Genomics, San Francisco, CA) and the NovaSeq6000 sequencer (Illumina, San Diego, CA). Cell Ranger 4.0 was utilized to generate sample-specific FASTQ files and reads were aligned to the mm10 reference genome using STAR ...
-
bioRxiv - Microbiology 2021Quote: ... Goe13 and lysogens and sequenced with the MiSeq system and reagent kit V.3 (2 x 300 bp) (Illumina, San Diego, CA, USA) and the NovaSeq system (2x 150bp ...
-
bioRxiv - Molecular Biology 2022Quote: ... The forward primers were 5’-CAA GCA GAA GAC GGC ATA CGA GAT XXX XXX GTG ACT GGA GTT CCT TGG CAC CCG AGA ATT CCA-3’ (in which XXX XXX represents Illumina’s indexing hexanucleotide sequences), and the reverse primer was 5’-AAT GAT ACG GCG ACC ACC GAG ATC TAC ACG TTC AGA GTT CTA CAG TCC GA-3’ ...
-
bioRxiv - Neuroscience 2021Quote: ... and a reverse primer 5′-GGA GTT CAG ACG TGT GCT CTT CCG ATC TTA CCA GGG TAT CTA ATC CT-3′ (28-nt Illumina adapter (in bold) followed by the 19 nt broad range bacterial primer 784R) ...
-
bioRxiv - Neuroscience 2021Quote: ... a forward primer 5′-CTT TCC CTA CAC GAC GCT CTT CCG ATC TAC GGR AGG CAG CAG-3 (28-nt Illumina adapter (in bold) followed the 14 nt broad range bacterial primer 343F ...
-
bioRxiv - Cancer Biology 2020Quote: ... Exome capture was performed in pools of 3 and subjected to paired end 75 sequencing on a HiSEQ4000 platform (Illumina, San Diego, USA).
-
bioRxiv - Cell Biology 2020Quote: ... DNA fragments were end-paired and phosphorylated at the 5’ end and successively adenylated at the 3’ end (following Illumina paired-end protocols), and the libraries ligated to the precapture adaptor were amplified and indexed via PCR ...