Labshake search
Citations for Illumina :
2251 - 2300 of 10000+ citations for DNA Purification kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2019Quote: ... and then incubated with 5 μl of Tn5 Transposase of TTE Mix V50 in 45 μL of 1 x TTBL buffer (TruePrep® DNA Library Prep kit V2 for Illumina®, Vazyme, China) at 37°C for 30 min ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 2 x 150 NextSeq500 Shotgun Libraries were prepared from each sample using an Illumina TruSeq® Nano DNA Library Prep Kit (Illumina Inc, CA, USA). The quality of each library was checked using the Agilent 4200 Tape Station (Agilent Technologies ...
-
bioRxiv - Immunology 2021Quote: ... libraries were prepared using the NEXTflex®Rapid Directional RNA-Seq Kit (Bio Scientific) and samples were sequenced 75 base pair single-end on Illumina NextSeq500 (Illumina, Utrecht DNA Sequencing Facility) and processed as described above ...
-
bioRxiv - Plant Biology 2021Quote: ... 10 ng of template DNA and index primer 1 (N7xx) and index primer 2 (N5xx) of Nextera XT Index Kit v2 Set A (Illumina, San Diego, CA, USA) according to the manufacturer’s instruction ...
-
bioRxiv - Genomics 2021Quote: ... 100ng of the pooled amplicons was used for subsequent sequencing using Nextera DNA Flex Library prep kit (Cat. No. 20018705, Illumina, San Diego, California USA). Briefly ...
-
bioRxiv - Genomics 2021Quote: ... Eight whole genome sequencing libraries with a median insert size of 550 bp were constructed using the Illumina TruSeq DNA PCR-free sample preparation kit (Illumina, San Diego, CA, USA), according to manufacturer’s protocols ...
-
bioRxiv - Cancer Biology 2020Quote: Libraries for cluster generation and DNA sequencing were prepared following an adapted method from Fisher et al49 using Illumina TruSeq Stranded mRNA LT Kit (Illumina, San Diego, CA, USA). Quality and quantity of the DNA libraries was assessed on a Agilent 2200 Tapestation (D1000 screentape ...
-
bioRxiv - Genomics 2022Quote: ... SW-8046-2) from libraries prepared using the Nextera XT DNA kit (Illumina, Inc, San Diego, CA, and sequenced on Illumina HiSeq4000 (2×150 bp). WGS data was obtained from six C ...
-
bioRxiv - Microbiology 2021Quote: ... To prepare 500 bp paired-end libraries of all isolates we used the Nextera XT DNA Library Preparation kit (Illumina, San Diego, CA, USA). Libraries were sequenced on the Illumina MiSeq sequencing platform using v2 sequencing chemistry ...
-
bioRxiv - Systems Biology 2019Quote: ... 600 pg of each cDNA library was fragmented and amplified for sequencing with the Nextera XT v2 DNA Library Preparation kit (Illumina, San Diego, CA, USA). Single-cell libraries at 1.8 pM (final average insert sizes ranging from 580 to 680 bp ...
-
bioRxiv - Genomics 2019Quote: ... Genomic DNA was simultaneously fragmented and tagged with sequencing adapters in a single step using Nextera transposome (Nextera XT DNA Library Preparation Kit, Illumina, San Diego, CA, USA). Tagmented DNA was then amplified with a 12-cycle PCR ...
-
bioRxiv - Microbiology 2021Quote: ... The trimmed DNA fragment sequences were then used to prepare a shotgun paired-end library with an average insert size of 350 bp using a TruSeq DNA Sample Prep kit (Illumina, San Diego, CA, USA). The library was sequenced on an Illumina MiSeq platform (Illumina ...
-
bioRxiv - Genomics 2021Quote: ... libraries with an average insert size of 450 bp were prepared by the University of Utah’s Huntsman Cancer Institute High-Throughput Genomics Core Facility using the Illumina TruSeq DNA PCR-Free Library Prep Kit (Illumina, San Diego, California, USA). 2 × 150 bp reads for each parent were generated on an Illumina NovaSeq 6000 instrument using the NovaSeq S2 reagent kit (Illumina ...
-
bioRxiv - Genomics 2021Quote: ... We then added adapters and barcodes onto the ends of the fragmented DNA to generate indexed sequencing libraries using TruSeq Library Preparation Kit (Illumina, San Diego, CA, U.S.). We performed capture-based target enrichment using the SeqCap EZ Hybridization and Wash Kit (Roche NimbleGen ...
-
bioRxiv - Genomics 2020Quote: ... BS-converted DNA (100 ng) of each sample was used for preparing the BS-seq library via the TruSeq DNA Methylation Kit (Illumina, EGMK91324, San Diego, CA). The quality of the libraries was checked using Qubit assays (Q32850 ...
-
bioRxiv - Molecular Biology 2021Quote: ... Libraries for WGS were prepared using Nextera XT DNA Library Prep Kit and sequencing was performed on the Illumina NextSeq500 machine as per manufacturer’s protocol (Illumina Inc., San Diego, California, USA) producing 2 x 151 base pair reads.
-
bioRxiv - Genomics 2021Quote: ... Paired-end sequencing libraries were prepared using the TruSeq Nano DNA Library Prep kit following the manufacturer’s specifications (Illumina Inc., San Diego, CA, USA). Out of the 150 libraries ...
-
bioRxiv - Genomics 2021Quote: ... Paired-end libraries were constructed from the double stranded cDNA by using Illumina DNA Prep with Enrichment kit (Illumina Inc., San Diego, CA, USA) following the manufacturer’s protocol ...
-
bioRxiv - Genomics 2020Quote: ... Paired-end sequencing libraries were constructed with an insert size of 500 bp using a TruSeq DNA PCR-Free kit (Illumina, San Diego, CA, USA) according to Illumina library preparation protocols ...
-
bioRxiv - Cell Biology 2022Quote: ... an average of 500 pg of amplified cDNA was used to prepare the libraries following Nextera XT DNA kit (Illumina Ref. FC-131-1096). Libraries were multiplexed by 6 on a high-output flow cells ...
-
bioRxiv - Microbiology 2022Quote: ... Purified PCR products were fragmented and tagged with the indexed adaptors using the Nextera DNA XT Sample Preparation Kit (Illumina, San Diego, CA, USA). The sequence library was quantified by using the Quant-iT PicoGreen dsDNA Assay Kit (Invitrogen) ...
-
bioRxiv - Microbiology 2022Quote: ... Amplicons of the V3-V4 region of the 16S rRNA gene and the and the ITS1 region and library prep were generated by Herculase II Fusion DNA Polymerase Nextera XT Index Kit V2 (Illumina, San Diego, CA, USA). The products of the library prep were validated by an Agilent Tapestation D1000 (Santa Clara ...
-
bioRxiv - Microbiology 2022Quote: Short read sequencing libraries were prepared using the Illumina DNA Prep kit in combination with IDT® UD Indexes Set A (Illumina, USA, #20018705, #20027213). Between 66.3 ng and 200 ng per sample was used as starting material ...
-
bioRxiv - Neuroscience 2022Quote: ... Sequencing libraries were prepared by transposase-assisted tagmentation and enrichment of 3’end of genes using Nextera XT DNA Library Prep Kit (Illumina, San Diego, CA, USA). The libraries were sequenced on the HiSeq2500 for 25 and 75 cycles paired-end reads ...
-
bioRxiv - Plant Biology 2022Quote: ... Illumina sequencing pair-end libraries with an insert size of 300 bp were prepared using the Nextera DNA Flex Library Prep Kit (Illumina, San Diego, CA, USA). After the libraries were constructed ...
-
bioRxiv - Microbiology 2023Quote: ... 5 µl of this reaction was used in a subsequent round of amplification using BC amp set 3 primers to add Illumina adapters to the sequences followed by amplification using the Nextera XT DNA Library Preparation Kit (Illumina cat. FC-131-1096) to add 5’ and 3’ indices to the library ...
-
bioRxiv - Immunology 2024Quote: ... transposition reaction was done with 350 rpm mixing and using the transposase from the Illumina Tagment DNA TDE1 Enzyme and Buffer Kit (Illumina, San Diego, CA, USA). Libraries were quantified using KAPA Library Quantification kit (Roche ...
-
bioRxiv - Microbiology 2024Quote: ... The extracted DNA was used to construct libraries for metagenomic shotgun sequencing using the Illumina Nextera XT 1⁄4 kit (Illumina, San Diego, CA, United States). Metagenomic shotgun sequencing libraries were sequenced on an Illumina NovaSeq system (Illumina ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... The libraries for Illumina sequencing were constructed according to standard protocols using the Illumina DNA prep kit and IDT 10 bp UDI indices (Illumina, San Diego, CA, USA) by the sequencing facility at SEQCENTER (PA ...
-
bioRxiv - Developmental Biology 2023Quote: ... ATAC-seq libraries were generated as described previously (Buenrostro, Giresi et al. 2013) using the Nextera XT DNA Library preparation kit (Illumina catalog: FC-131-1024). Sequencing was performed on an Illumina HiSeq 2500 with 30 - 40 million 75bp paired-end reads ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... the HMW DNA was prepared for sequencing using a Chromium Genome Linked Reads Kit (10X Genomics Inc., Pleasanton, CA) and sequenced on a HiSeq 2500 DNA Sequencing Platform (Illumina Inc., San Diego, CA). The linked-read output data were assembled using the Supernova assembler (Weisenfeld et al. ...
-
bioRxiv - Bioengineering 2023Quote: ... The PCR products were subjected to sequencing library construction using the TruSeq® DNA PCR-Free Sample Preparation Kit (Illumina, San Diego, CA, USA). The libraries were loaded on a NovaSeq 6000 system (Illumina ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... and 0.5ng of each fragment mixed and used to construct barcoded sequencing libraries with the Nextera XT DNA Library Preparation Kit (Illumina, cat. no.FC-131-1096). Libraries were multiplexed and sequences were determined using Miseq 2 × 250 Illumina sequencing.
-
bioRxiv - Microbiology 2023Quote: ... The libraries were prepared using Nextera XT DNA Sample Preparation Kit and sequenced on MiSeq or NovaSeq 6000 platform (Illumina, San Diego, CA, USA). Raw reads were quality- and adaptor-trimmed using Trimmomatic v0.39 (Bolger at al. ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... sequencing library with a peak insert size of 535 bp was constructed using 200 ng of genomic DNA with a TruSeq Nano LT library preparation kit (Cat # FC-121-4002, Illumina, San Diego, CA, USA) according to the kit supplier’s instructions ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... library with a peak span size of 1450 bp and a mean span size of 1027 bp was prepared from 570 ng of genomic DNA by tagmentation using an MP library preparation kit (Cat # FC-132-1001, Illumina, San Diego, CA, USA), without size selection ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... Libraries with an insert size of 350 bp were constructed using a TruSeq Nano DNA HT Sample Preparation Kit (Illumina, San Diego, California, U.S.A.) following manufacturer’s recommendations ...
-
bioRxiv - Cancer Biology 2023Quote: ... cDNA samples were then diluted to 0.2-0.3 ng per uL and 1 ng of cDNA was carried over into library preparation using the Nextera XT DNA Library Preparation Kit (Illumina, cat. # FC-131-1096) following the manufacturer’s protocol ...
-
bioRxiv - Physiology 2023Quote: ... A second round of PCR was performed with 50 ng DNA input for 8 cycles to attach Nextera XT indices and adapters using the Illumina Nextera XT Index Kit (Illumina, Catalog #FC-131-200x) and Phusion HF PCR master mix (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... a sequencing library was generated from 1 ng of the resulting SAG DNA with the NexteraXT library preparation kit (Illumina, San Diego, CA, USA) and the library was then sequenced on an Illumina MiSeq instrument (2×300 bp) ...
-
bioRxiv - Microbiology 2023Quote: Phage DNA was subjected to Illumina sequencing for dsDNA by paired-end library preparation with the Nextera XT DNA Library Preparation Kit (Illumina, San Diego, CA, USA) as recommended by the manufacturer ...
-
bioRxiv - Microbiology 2023Quote: ... Libraries for the run at NMBU and the first run at SLU (August 2021) were prepared using the Nextera XT DNA Library Preparation kit (Illumina, San Diego, CA, USA) and paired-end 250 bp sequenced on an Illumina MiSeq ...
-
bioRxiv - Microbiology 2023Quote: ... The DNA libraries were then prepared at the Institut Pasteur Mutualized Platform for Microbiology (P2M) with the Nextera XT kit (Illumina, San Diego, CA, USA) and sequencing was performed with the NextSeq 500 system (Illumina) ...
-
bioRxiv - Microbiology 2024Quote: ... Pair-end libraries were generated using a Nextera XT DNA Kit and sequenced using a NovaSeq 6000 system (both from Illumina, San Diego, CA, USA). Sequenced data were preprocessed using Trimmomatic v.0.33 and FastQC v.0.12.1 ...
-
bioRxiv - Genetics 2024Quote: ... DNA sequencing libraries were prepared using Illumina TruSeq DNA Preparation Kits at the facilities of Novogene and then sequenced on a NovaSeq 6000 platform (Illumina, California, San Diego, USA) as 150PE reads to a sequencing depth of 15X ...
-
bioRxiv - Molecular Biology 2024Quote: ... Whole-genome sequences were obtained (MiSeq Desktop Sequencer, 2×250 v2 paired-end chemistry and the Nextera XT DNA Library Preparation Kit, Illumina, San Diego, California, US) per manufacturer’s instructions.
-
bioRxiv - Microbiology 2024Quote: Paired-end libraries (2×151 bp) were prepared for a subset of samples using Illumina TruSeq DNA library preparation kit (Illumina, San Diego, CA, USA) and sequenced on the Illumina NextSeq500 platform ...
-
bioRxiv - Genetics 2019Quote: ... Cells were incubated in Tagmentation mix (Tagmentation DNA buffer Illumina 15027866; Tagmentation DNA enzyme Illumina 15027865) for 30 min at 37°C ...
-
bioRxiv - Immunology 2021Quote: ... 0.25 μL Nextera TDE1 Tagment DNA enzyme and 1.25 μL TD Tagment DNA buffer (Illumina, #20034198). Tagmented DNA was ligated to a unique i5/i7 barcoded primer combinations using the Illumina Nextera XT Index Kit v2 and KAPA HiFi HotStart ReadyMix (Roche ...
-
bioRxiv - Plant Biology 2020Quote: ... The immunoprecipitated DNA and input DNA were subjected to sequencing on the HiSeq 2000 platform (Illumina) by the Novogene Corporation ...