Labshake search
Citations for Illumina :
101 - 125 of 125 citations for Ammonium Polyphosphate phase II 02 since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2024Quote: ... DNA eluted from Chromatin-immunoprecipitated was prepared for library construction by using NEBNext® Ultra™ II DNA Library Prep with Sample Purification Beads according to standard operating procedures and then sequenced using HiSeq2000 (Illumina). Paired-end raw reads were first mapped to the Arabidopsis genome (TAIR10 ...
-
bioRxiv - Genetics 2024Quote: Total RNA from mouse glomeruli was sequenced on a HiSeq 4000 following standard workflow using NEBNext Ultra II RNA Library Preparation kit (New Englab Biolabs, MA)(Illumina, CA) and paired-end sequencing (Genewiz ...
-
bioRxiv - Genomics 2024Quote: ... libraries were quality controlled and quantified using an Agilent Bio-analyzer Chip DNA 1000 series II before being sequenced directly utilizing the high-throughput Illumina HiSeq sequencing equipment (Illumina, Inc.). The raw data files were submitted to the NCBI SRA database under the Bio Project PRJNA1117754 (http://www.ncbi.nlm.nih.gov/bioproject/1117754).
-
bioRxiv - Genomics 2024Quote: ... we employed PacBio HiFi sequencing, Illumina sequencing and Hi-C sequencing using the PacBio Sequel II (Pacific Biosciences, USA) and Illumina Novaseq 6000 (Illumina, USA) plat forms ...
-
bioRxiv - Developmental Biology 2021Quote: The resulting 79,472,462 paired end reads (NCBI PRJNA690950) were combined with an older library (16,225,145 paired end reads sequenced on an Illumina GA II; NBCI SRR1145735) for annotation of protein coding regions.
-
bioRxiv - Neuroscience 2021Quote: ... Hippocampus RNA-seq libraries were prepared in accordance with New England Biolab protocols (NEBNext_ Ultra II RNA library Prep kit for Illumina, NEB, USA). Briefly ...
-
bioRxiv - Immunology 2022Quote: ... libraries for sequencing were prepared using the NEBNext® Ultra™ II RNA Library Prep Kit for Illumina® following the manufacturer’s instructions (Illumina). Quality of all RNA and library preparations were evaluated with BioAnalyser 2100 (Agilent) ...
-
bioRxiv - Microbiology 2023Quote: ... Preparation of cDNA fragment libraries was performed using the NEBNext® UltraTM II Directional RNA Library Prep Kit for Illumina® (Illumina). Sequencing was carried out on the Illumina NovaSeq platform (10 M paired-end reads ...
-
bioRxiv - Developmental Biology 2023Quote: ... Approximately 300 ng of RNA was used for library prep (NEBNext® Ultra™ II Directional RNA Library Prep Kit for Illumina) following standard kit procedure ...
-
bioRxiv - Microbiology 2022Quote: ... The same amount of the seven purified 3-cycle PCR products were further amplified using Platinum SuperFi II and the index primers from Nextera XT Index Kit v2 (Illumina cat. 15052163). The PCR products were purified using 1.8× beads ...
-
bioRxiv - Genomics 2023Quote: ... single-indexed and dual-indexed DNA libraries were generated using the NEBNextUltra II DNA Library Prep kit from Illumina (New England Biolabs). Single-indexed libraries were sequenced 50 nt single end reads on a HiSeq 2500 (Illumina ...
-
bioRxiv - Cell Biology 2022Quote: ... 1,500ng of RNA at 50ng/μl was processed using Ribo-Zero Gold purification (QIAseq FastSelect -rRNA HMR Kit #334387) and NEBNext® Ultra™ II RNA Library Prep Kit (Illumina #E7770L). cDNA was sequenced using paired-end 150bp chemistry on a HiSeq 4000 instrument (Illumina ...
-
bioRxiv - Microbiology 2022Quote: ... Libraries were prepared using the New England Biolabs NEBNext rRNA depletion kit (Bacteria) and NEBNext Ultra II Directional RNA library prep kit (Illumina, San Diego, CA). The libraries were quantified by KAPA qPCR library quantitation assays and sequenced paired-end using MiSeq platform (Illumina ...
-
bioRxiv - Genetics 2020Quote: ... sequencer-ready fragments were size selected (∼200-500 bp) and the RAD-seq libraries sequenced on a Genome Analyzer II (Illumina, San Diego, CA), paired-end 2 x 100 bp mode ...
-
bioRxiv - Genomics 2024Quote: ... where DNA libraries were constructed using NEB Ultra II custom kit on an Agilent Bravo WS automation system and sequenced on the Illumina HiSeq X10 platform (Illumina Inc, California, USA) to produce paired-end raw reads of 150 base pairs (bp) ...
-
bioRxiv - Genomics 2020Quote: Fragmented cDNA Sequencing libraries were generated from 100ng of Total RNA using NEBNext Ultra II with polyA isolation module (Illumina, San Diego, California, USA) according to manufacturer’s protocol ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Sequencing libraries were prepared using NEBNext Ultra II directional RNA library kit and paired-end sequenced (150bp) in an Illumina HiSeq3000 (Illumina Inc., San Diego, USA) instrument ...
-
bioRxiv - Immunology 2021Quote: ... Library preparation was done using a NEBNext Ultra II Directional RNA Library Prep Kit for Illumina with poly-A selection (Illumina, San Diego, CA, USA) following the manufacturer’s instructions ...
-
bioRxiv - Plant Biology 2023Quote: ... cDNA libraries were constructed from 1 μg/sample of total RNA using library preparation kits (NEBNext Ultra II RNA Library Prep Kit for Illumina 7770L, NEBNext Multiplex Oligos for Illumina E7335S, NEBNext Poly(A) mRNA Magnetic Isolation Module E7490L ...
-
bioRxiv - Microbiology 2022Quote: ... Amplicons of the V3-V4 region of the 16S rRNA gene and the and the ITS1 region and library prep were generated by Herculase II Fusion DNA Polymerase Nextera XT Index Kit V2 (Illumina, San Diego, CA, USA). The products of the library prep were validated by an Agilent Tapestation D1000 (Santa Clara ...
-
bioRxiv - Genetics 2024Quote: ... To acquire an accurate genome assembly, several sequencing platforms were utilized, including Sequel II (Pacific Biosciences, Menlo Park, CA, USA) and Novaseq 6000 (Illumina, San Diego, CA, USA). For chromosome conformation capture sequencing ...
-
bioRxiv - Plant Biology 2024Quote: ... and the DNA was purified before conversion into a sequencing library (NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® (E7645)) using Illumina-compatible adaptors (NEBNext® Multiplex Oligos for Illumina® (Index Primers Set 1 ...
-
bioRxiv - Microbiology 2022Quote: ... 5 ng of total RNA was used for intact RNA library preparation (NEBNext Ultra II Directional RNA Library Prep Kit for Illumina (NEB #E7760, New England BioLabs). To obtain sufficient RNA for the analysis of oral samples ...
-
bioRxiv - Systems Biology 2024Quote: ... DNA libraries were prepared using the NEBNext® Ultra™ II DNA Library Prep Kit and then sequenced on the Illumina MiSeq platform (Illumina, San Diego, CA, USA) at the Kunming Institute of Botany ...
-
bioRxiv - Evolutionary Biology 2024Quote: ... 600 ng of the amplified DNA was pooled and employed to build a single paired end (2 × 150 bp) genomic library using the NEBNext® UltraTM II DNA Library Prep Kit by Illumina (New England Biolabs, Ipswich, MA, USA) (Asem et al. ...