Labshake search
Citations for Illumina :
1301 - 1350 of 3793 citations for Laemmli Sample Buffer 2X Solution since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... Sequencing libraries were prepared using TruSeq© Stranded mRNA sample preparation kit (Illumina) and paired end 150-bp sequencing using Illumina HiSeq 2000 was performed by Novogene (Hong Kong) ...
-
bioRxiv - Plant Biology 2023Quote: ... Then libraries were constructed using the Nextera XT DNA Sample Preparation Kit (Illumina) following manufacturer’s instructions.
-
bioRxiv - Cancer Biology 2023Quote: ... was added prior to running the sample on an Miseq Sequencer System (Illumina) to generate paired 2 × 250bp reads ...
-
bioRxiv - Genomics 2023Quote: ... The total RNA sample was subjected to poly-A selection followed by Illumina TruSeq RNA library preparation and a total of 24,187,884 read pairs (7.3 Gbp ...
-
bioRxiv - Immunology 2023Quote: ... cDNA libraries were generated using the TruSeq Sample Preparation v.2 Guide (Illumina) and paired end-sequenced on the NovaSeq 6000 (Illumina) ...
-
bioRxiv - Immunology 2023Quote: ... cDNA Libraries were generated using the TruSeq Sample Preparation v.2 Guide (Illumina) and paired end-sequenced on the NovaSeq 6000 (Illumina ...
-
bioRxiv - Molecular Biology 2023Quote: ... All 36 sturgeon gill samples were sequenced on a single NovaSeq 6000 (Illumina) lane producing 1.53 billion total reads with an average of 42,528,434 (± 17,812,372 SD ...
-
bioRxiv - Genetics 2023Quote: ... The library was prepared with the Nextera XT DNA Sample Prep Kit (Illumina) following the manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2023Quote: ... Samples were run using paired end 50 cycle reads on HiSeq 4000 (Illumina) or the NovaSeq 6000 (Illumina ...
-
bioRxiv - Zoology 2023Quote: ... were constructed using Truseq™ RNA sample prep Kit (Illumina, San Diego, USA) according to the instruction ...
-
bioRxiv - Molecular Biology 2023Quote: ... Strand-specific libraries were prepared using a TruSeq RNA Sample Preparation Kit (Illumina) and the dUTP method ...
-
bioRxiv - Cell Biology 2024Quote: ... Libraries were then created with the Nextera XT DNA Sample Preparation Kit (Illumina) and sequenced with an Illumina HiSeq 2500 system ...
-
bioRxiv - Genomics 2024Quote: ... Samples were finally demultiplexed using bcl2fastq v2.20 Conversion Software (Illumina, San Diego, CA).
-
bioRxiv - Neuroscience 2024Quote: ... Samples were clustered and sequenced using NovaSeq S2 reagents (NovaSeq S2 Run, Illumina) with 80 samples/flow cell and 50 base paired end reads (targeted sequencing depth=45 million reads/sample).
-
bioRxiv - Genomics 2024Quote: A genotyping of AIDA samples was performed using Infinium Global Screening Array (Illumina). SNPs on the nonPAR X chromosome were treated as diploid in males and heterozygous genotypes of such SNPs were converted into ‘missing’ with PLINK (v1.90b4.4)48 ...
-
bioRxiv - Plant Biology 2024Quote: ... Libraries for RNA-seq were prepared with a TruSeq sample preparation kit (Illumina) and sequenced by Hi-seq 2000 (ICBR ...
-
bioRxiv - Plant Biology 2024Quote: ... The captured samples were sequenced on the HiSeq4000 sequencing platform (Illumina, California, USA) using a paired end sequencing strategy of 2 reads of 150 bases each (approximately 10 million reads per accession) ...
-
bioRxiv - Microbiology 2024Quote: ... Transcriptome libraries were constructed using the TruSeqTM RNA Sample Preparation Kit from Illumina and sequenced on the Illumina NovaSeqTM 6000 platform ...
-
bioRxiv - Immunology 2024Quote: ... using the NebNext Small RNA Sample Prep kit with 3’ sRNA Adapter (Illumina) according to the manufacturer’s protocol with 12 cycles of PCR amplification in the last step followed by DNA purification with AMPpure XP beads cleanup ...
-
bioRxiv - Molecular Biology 2024Quote: ... Samples were submitted and sequenced at the Broad Institute using a HiSeq2000 (Illumina) as previously described39 ...
-
bioRxiv - Microbiology 2024Quote: ... 48 samples underwent ribodepletion using the RiboZero Gold kit (Illumina, San Diego, USA). The library preparation was elaborated using the NEBNext® SingleCell/Low Input cDNA Synthesis kit (New England Biolabs) ...
-
bioRxiv - Pathology 2024Quote: ... sequencing run was used to sample balance on a NovaSeq S2 flowcell (Illumina) using a 2×50 bp sequencing reaction targeting >90,000 reads/cell.
-
bioRxiv - Neuroscience 2024Quote: ... The libraries were prepared using the TruSeq DNA LT Sample Prep Kit (Illumina) according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2024Quote: ... A metagenome from the LBR was used for the MC samples (see Illumina library preparation ...
-
bioRxiv - Biochemistry 2024Quote: ... Total RNA samples (100-200 ng) were hybridized with Ribo-Zero Gold (Illumina) to substantially deplete cytoplasmic and mitochondrial rRNA from the samples ...
-
bioRxiv - Plant Biology 2024Quote: ... Twelve libraries were generated by the TruSeq RNA Sample Preparation v2® (Illumina) (Table S3) ...
-
bioRxiv - Plant Biology 2024Quote: ... The libraries were generated by the TruSeq RNA Sample Preparation v2® (Illumina) (Table S3) ...
-
bioRxiv - Cancer Biology 2024Quote: ... The multiplexed samples were paired-end sequenced using the NovaSeq 6000 platform (Illumina) to generate 101 bp reads ...
-
bioRxiv - Cancer Biology 2024Quote: ... The multiplexed samples were paired-end sequenced using the NovaSeq 6000 platform (Illumina) to generate 101 bp reads.
-
bioRxiv - Genetics 2024Quote: ... Samples were sequenced using 1 × 30 bp chemistry on a NextSeq 2000 (Illumina).
-
bioRxiv - Cancer Biology 2024Quote: Libraries were prepared using the TruSeq Stranded mRNA LT Sample Prep Kit (Illumina) and sequenced on an Illumina NovaSeq6000 S4 v1.5 sequencer by Psomagen ...
-
bioRxiv - Genetics 2024Quote: ... the samples were sequenced on a Nextseq 2000 under paired-end conditions (Illumina). After filtering ...
-
bioRxiv - Cell Biology 2024Quote: ... and a 2 pM solution of this pool was sequenced unidirectionally on a NextSeq® 500 System (Illumina) at GeneCore ...
-
bioRxiv - Genetics 2021Quote: ... we added 2.50 μL of TD Buffer and 0.5 μL of TDE1 Enzyme (Illumina) to 1 μL of normalized DNA and incubated the samples in a thermocycler at 55 °C for 20 minutes (Figure 1 ...
-
bioRxiv - Neuroscience 2021Quote: ... 200-250 pg of cDNA was added to 2.5 µL tagment DNA buffer (Illumina) and 1.25 µL of amplicon tagment mix (Illumina ...
-
bioRxiv - Microbiology 2020Quote: ... This denatured library was diluted to 12 pM loading concentration with HT1 buffer (Illumina). PhiX control (20 pM ...
-
bioRxiv - Cancer Biology 2021Quote: ... genomic DNA (gDNA) was diluted to 20 ng/μL using Resuspension Buffer (RSB, Illumina) and 55 μL were transferred to Covaris microTubes (Covaris ...
-
bioRxiv - Genomics 2021Quote: ... Pellets were resuspended in 25 μL tagmentation mix (Tagment DNA buffer from Illumina, #15027866) containing 2.5 μL Tagment DNA Enzyme (Illumina #15027865 ...
-
bioRxiv - Cancer Biology 2023Quote: ... One barcoded library was prepared per plate using TD buffer and TDE1 enzyme (Illumina) for tagmentation and KAPA HiFi HotStart Ready Mix (Roche ...
-
bioRxiv - Molecular Biology 2022Quote: ... The nuclei were re-suspended in 20 μl of Tn5 transposase reaction buffer (Illumina). After tagmentation ...
-
bioRxiv - Cancer Biology 2023Quote: ... The transposition reaction was performed using Tagment DNA TDE1 Enzyme and Buffer Kit (Illumina) and 4.7 µL TDE1 Tagment DNA enzyme per sample in a 50-µL total reaction volume ...
-
bioRxiv - Immunology 2023Quote: ... Tn5 tagmentation was performed using Illumina Tagment DNA TDE1 Enzyme and Buffer Kits (Illumina) at 37℃ for 30 min ...
-
bioRxiv - Cancer Biology 2022Quote: ... Precipitated chromatin was washed and incubated in Tagmentation buffer containing Tn5 transposase enzyme (Illumina). Samples were reverse crosslinked for 4 hours at 65°C ...
-
bioRxiv - Plant Biology 2023Quote: ... one microgram of crosslinked enriched chloroplasts was resuspended in 1X Tn5 reaction buffer (Illumina) and assayed according to the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2024Quote: ... Pelleted cells were transposed using Tagment DNA TDE1 Enzyme and Buffer Kit (Illumina, # 20034197) for 60 min at 37 °C with shaking ...
-
bioRxiv - Cancer Biology 2024Quote: ... The pellet was incubated in the transposase reaction mix (25µL 2×TD buffer (Illumina), 2.5µL transposase (Illumina Cat# FC-121-1030 ...
-
bioRxiv - Molecular Biology 2020Quote: ... Pooled samples were sequenced using a PE75 run on a NextSeq 500 instrument (Illumina). Alignment to the mm10 reference genome was performed using Bowtie 2.2.4 ...
-
bioRxiv - Cell Biology 2020Quote: ... Samples were sequenced on a NovaSeq 6000 Illumina platform instrument (Illumina, San Diego, CA). An average of 2741 cells per sample were analyzed with an average post normalized mean reads/cell of 312,995 ...
-
bioRxiv - Genetics 2021Quote: Samples were assayed following the protocol for Infinium XT bead chip technology (Illumina Ltd). SNP clustering and allele calling was performed using GenomeStudio Polyploid software (Illumina Ltd ...
-
bioRxiv - Developmental Biology 2021Quote: Tagmentation was carried out using the Illumina Nextera XT DNA sample preparation kit (Illumina) according to an optimised Tagmentation protocol (Fluidigm) ...