Labshake search
Citations for Illumina :
51 - 100 of 2112 citations for 7H Purine 7 acetamide N dibenzofuran 3 yl 1 2 3 6 tetrahydro 1 3 dimethyl 2 6 dioxo 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2023Quote: ... 3) carried no SNP or indel within 50 bp in their 5’ or 3’ flanking regions (Illumina probe design requirement); and 4 ...
-
bioRxiv - Microbiology 2023Quote: The V3/V4 variable region of the 16S rRNA gene was amplified using primers 341F 5’CCTACGGGNGGCWGCAG′3 and 785R 5′GACTACHVGGGTATCTAATCC′3 (Klindworth et al., 2013 with Illumina Nextera XT overhang adapters for a dual-barcoding PCR library preparation approach ...
-
bioRxiv - Biophysics 2021Quote: ... while the reverse primer (3’ P7 Illumina adapter) differed by the barcode index (oligo sequences in Table S1) ...
-
bioRxiv - Genomics 2019Quote: ... to generate ~3 GB data (Illumina, Inc, USA). The total yield of the Number of Paired end was 26,263,128 with the maximum data of 3.78 GB ...
-
A tale of two transcriptomic responses in agricultural pests via host defenses and viral replicationbioRxiv - Genomics 2020Quote: ... A TruSeq SBS sequencing kit version 3 (Illumina) was used following the manufacturer’s instructions to generate the sequencing libraries ...
-
bioRxiv - Biophysics 2022Quote: ... while the reverse primer (3’ P7 Illumina adapter) differed by the barcode index (oligo sequences in Supplementary Table 1) ...
-
bioRxiv - Genomics 2023Quote: ... and alternating reverse oligos (3’ P7 Illumina adapter). The demulitplexing primers used for PCR2 are listed in Extended Data Table 4 ...
-
bioRxiv - Biophysics 2023Quote: ... while the reverse primer (3’ P7 Illumina adapter) differed by the barcode index (Supplementary Table 3 ...
-
bioRxiv - Microbiology 2021Quote: ... Goe13 and lysogens and sequenced with the MiSeq system and reagent kit V.3 (2 x 300 bp) (Illumina, San Diego, CA, USA) and the NovaSeq system (2x 150bp ...
-
bioRxiv - Molecular Biology 2019Quote: ... Biomark Access Array system followed by sequencing with 2×225 base pair reads on a MiSeq instrument using version 3 chemistry (Illumina, San Diego, CA). FASTQ files were processed through a custom bioinformatics pipeline (ScanIndel ...
-
bioRxiv - Molecular Biology 2023Quote: ... and each sample was sequenced in 3 different lanes (3 technical replicates per sample) on an Illumina HiSeq platform (Illumina, USA).
-
bioRxiv - Cancer Biology 2020Quote: The RNA-seq libraries (n=3 per experimental group) were prepared using the NEBNext Ultra II RNA library prep kit from Illumina (New England Biolabs Inc. ...
-
bioRxiv - Molecular Biology 2023Quote: ... RNA-seq libraries for yeast (n = 3 per tested condition) and neuroblastoma cells (n = 3 per tested condition) were prepared according to the TruSeq stranded mRNA protocol (Illumina) and 101-bp single-end reads produced on an Illumina NovaSeq 6000 instrument ...
-
bioRxiv - Genomics 2020Quote: ... sequencing libraries were prepared from 1 ng gDNA using the Nextera XT Library Preparation Kit v.3 (Illumina) and sequenced on the Illumina NextSeq system (paired end 2 x 150 bp insert size) ...
-
bioRxiv - Microbiology 2019Quote: 16S amplicon sequencing targeting the V3 and V4 variable regions of the 16S rRNA (341F: 5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 805R: 5’- GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATC C-3’) was performed on the Illumina MiSeq platform (Illumina, California, USA) according to manufacturer’s guidelines and generated paired-end reads of 300bp in each direction ...
-
bioRxiv - Neuroscience 2021Quote: ... using TruSeq SR Cluster Kit 3-cBot-HS (Illumina) and TruSeq SBS Kit 3-HS (Illumina ...
-
bioRxiv - Immunology 2024Quote: ... 3 biological replicates were sequenced with NextsSeq 550 (Illumina). For data analysis ...
-
bioRxiv - Cancer Biology 2020Quote: ... in paired-end mode on Illumina (2×101 bp) using TrueSeq DNA exome kit (v.6) (Illumina Inc.). Paired-end reads were aligned to the human reference genome sequence GRCh38 using BWA–MEM (V0.715-r1140 ...
-
bioRxiv - Microbiology 2023Quote: ... The V3-V4 region of the 16S ribosomal RNA gene was amplified by PCR with universal bacterial primer sets (5’-TCGTCGGCAGCGTCAGATGTGTATAAGAGACAGCCTACGGGNGGCWGCAG-3’ and 5’-GTCTCGTGGGCTCGGAGATGTGTATAAGAGACAGGACTACHVGGGTATCTAATCC-3’) and was sequenced using MiSeq Reagent kit v3 (600 cycle) (Illumina Inc., California, US). The sequence data were analyzed using QIIME2 (https://qiime2.org/ ...
-
bioRxiv - Developmental Biology 2024Quote: ... library construction was immediately carried out using a Chromium Single Cell 3’ Reagent Kit (Version 3) and sequenced on an Illumina HiSeq 4000 or an Illumina NextSeq2000 (Illumina, cat no. 20040559) by the Technion Medicine Faculty Azrieli-Technion Genomics Center ...
-
bioRxiv - Microbiology 2019Quote: ... and the primers V3F - 5’-CCTACGGGNGGCWGCAG-3’ and V4R – 5’-GACTACHVGGGTATCTAATCC-3’ [28] with the addition of the appropriate Illumina Nextera XT overhang adapter sequences (Illumina, San Diego, CA, USA). Following purification using a magnetic bead capture kit (Ampure ...
-
bioRxiv - Molecular Biology 2019Quote: ... and 3’ end adenylation per the TruSeq protocol (Illumina, Inc.), libraries were constructed using an Apollo 324 automated library system ...
-
bioRxiv - Molecular Biology 2019Quote: ... v1.5 small RNA 3’ adaptor kit (Illumina FC-102-1009) or by using TruSeq directional small RNA kit (Illumina RS-200-0012) ...
-
bioRxiv - Genomics 2019Quote: ... the sequence 3’ of the indices were bound by Illumina’s Sequencing Primers ...
-
bioRxiv - Plant Biology 2023Quote: ... with the MiSeq reagent kit version 3 (600 cycles; Illumina). The reads were cleaned up using the cutadapt ver ...
-
bioRxiv - Immunology 2023Quote: ... ADT and 3’ Gexp libraries were mixed at the ratio of 1:5 and sequenced on NovaSeq 6000 sequencer (Illumina) with a configuration of 28/8/0/91-bp for cell barcode ...
-
bioRxiv - Molecular Biology 2024Quote: ... CUT&RUN libraries (10–20 Mio reads per sample and 1/3 of reads for the controls) were sequenced on a NovaSeq 6000 (Illumina) paired end 100 bp at the Deep Sequencing Facility (Max Planck Institute for Immunobiology and Epigenetics ...
-
bioRxiv - Developmental Biology 2024Quote: ... Amplification was carried out using 3 µl of NMP per sample and adding 1 µl of each dual-indexed (i7 and i5; Illumina) primer ...
-
bioRxiv - Genetics 2021Quote: ... 6 μL of denatured PhiX control (prepared according to Illumina protocol, final concentration 1%) was added to the library ...
-
bioRxiv - Microbiology 2020Quote: ... Shotgun metagenomic libraries were then constructed from a subset of these animals (LDC N = 15, DDC N = 7, CZMD N = 7) using the Nextera XT kit (Illumina, San Diego, CA USA) and sequenced on and Illumina HiSeq 3000 using a 150bp PE sequencing kit (Illumina).
-
bioRxiv - Evolutionary Biology 2019Quote: ... we added four mate pair libraries (3 kb, 5 kb, 7 kb, 8 kb) prepared using a Nextera Mate Pair Library Prep kit (Illumina, San Diego, CA, USA). Each library was sequenced on an Illumina HiSeq 2500 sequencer by Novogene (Sacramento ...
-
bioRxiv - Genetics 2019Quote: ... The coding and splice-site regions of genes susceptible to hereditary arrhythmia and cardiomyopathies(10) were sequenced for probands II:3 and III-7 using Illumina HiSeq2500 Analyzer (Illumina, San Diego, CA, USA)(11) ...
-
bioRxiv - Immunology 2023Quote: ... Sequencing was performed in 3 sequencing unit of NovaSeq 6000 (Illumina) (100-nt-length reads ...
-
bioRxiv - Immunology 2023Quote: The 3’ adapters were ligated according to the TruSeq kit (Illumina) manufacturer’s instructions ...
-
bioRxiv - Immunology 2023Quote: ... dual-indexed 3’ DGE libraries were prepared using Nextera XT (Illumina) and sequenced to depth on the NovaseqS4 platform with a paired-end read structure (R1 ...
-
bioRxiv - Genomics 2023Quote: ... RNA was extracted from similar pooled-samples (N = 3) using the ZYMO (Irvine, CA, USA) direct-zol miniprep kit (Cat. # R2050) and sequenced using NovaSeq (Illumina, San Diego, CA, USA) paired-end (150 bp ...
-
bioRxiv - Genomics 2023Quote: ... Libraries were prepared using the QuantSeq 3’ mRNA-Seq Library Prep Kit FWD for Illumina and UMI Second Strand Synthesis Module for QuantSeq FWD (Illumina, Read 1) from Lexogen (015.96 and 081.96 ...
-
bioRxiv - Molecular Biology 2020Quote: ... was performed using the SureCell WTA 3’ library prep kit (Illumina, 20014279) according to manufacturer’s instructions with minor modifications ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... using 300-cycle kit (v.3, Illumina, Inc., San Diego, CA, USA) to obtain 150 bp paired-end reads.
-
bioRxiv - Neuroscience 2021Quote: ... 3′ gene expression libraries were dual-index sequenced using NextSeq 150bp (Illumina) flow cells by the Duke Center for Genomic and Computational Biology Core Facility.
-
bioRxiv - Cell Biology 2021Quote: ... The final constructed 3’- biased single cell libraries were sequenced by Illumina Nextseq500 machine ...
-
bioRxiv - Immunology 2022Quote: ... and mixed with 3 μl of Illumina TDE1 Tn5 transposase (Illumina, 15027916). Transposition was performed by incubating the prepared reactions on a C1000 Touch thermal cycler with 96–Deep Well Reaction Module (Bio-Rad ...
-
bioRxiv - Molecular Biology 2022Quote: ... and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7), with both containing 8N barcodes for multiplexing.
-
bioRxiv - Cancer Biology 2022Quote: ... All of the 3′ and 5′ flowcells were demultiplexed with bcl2fastq (Illumina). FASTQ files were processed with Cell Ranger v7.0.1 (10x Genomics) ...
-
bioRxiv - Microbiology 2023Quote: ... or matched the PhiX version 3 positive control (Illumina; FC-110-3001). After filtering ...
-
bioRxiv - Microbiology 2023Quote: ... or matching the PhiX version 3 positive control (Illumina; FC-110-3001). After filtering ...
-
bioRxiv - Genetics 2023Quote: ... The final constructed 3’-biased single cell libraries were sequenced by Illumina Novaseq6000 machine ...
-
bioRxiv - Developmental Biology 2023Quote: ... distributed over 3 lanes of a HiSeq 2500 with v4 chemistry (Illumina). Sequencing was performed by the Next Generation Sequencing Facility at Vienna BioCenter Core Facilities (VBCF) ...
-
bioRxiv - Microbiology 2023Quote: ... The prepared library was sequenced using a MiSeq sequencing system with a V3 reagent kit (300 × 2 bp; Illumina, 4–6 samples). Lake Biwa viral contigs/genomes (LBVs ...
-
bioRxiv - Molecular Biology 2022Quote: ... 6 pM of DNA library spiked with 1% PhiX viral DNA was clustered on cBot (Illumina) and then sequenced on a HiScanSQ module (Illumina) ...