Labshake search
Citations for Illumina :
8501 - 8550 of 10000+ citations for HDM Fluorescent Kit 2 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... Libraries for next-generation sequencing were constructed from 1-ng amplified genomes using the Nextera XT DNA Library Preparation Kit (Illumina) and sequenced using the MiSeq Reagent Kit v3 on the MiSeq Platform (Illumina) ...
-
bioRxiv - Genomics 2023Quote: Total RNA was extracted from the collected leaf samples using the Dynabeads mRNA DIRECT Kit (Illumina, San Diego, CA, USA) and quantified and assessed for integrity using a NanoDrop spectrophotometer and an Agilent Bioanalyzer ...
-
bioRxiv - Genomics 2023Quote: ... 96 libraries from 16 animals in batch 1 were performed using TruSeq RNA Library Preparation Kit v2 (RS-122-2001, RS-122-2002, Illumina) and were sequenced 50 base pairs ...
-
bioRxiv - Genomics 2023Quote: ... Illumina sequencing library was prepared using a TruSeq-based protocol (KAPA LTP Library Preparation kit Illumina, catalog num. 7961898001, Roche) and manufacturer protocol was strictly followed ...
-
bioRxiv - Microbiology 2023Quote: ... RNAs extracted from immunoprecipitated complexes using Ago2 and GFP antibody were used to generate small RNA sequencing libraries using TruSeq Small RNA Kit (Illumina), according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: ... Libraries were constructed using ∼50 ng of mRNA using the Kapa Stranded RNA-Seq Library Preparation Kit (KAPA Biosystems, Illumina). Indexes were designed according to TruSeq RNA UD specifications (#20020591 ...
-
bioRxiv - Plant Biology 2023Quote: ... Libraries were made using the TruSeq Small RNA Library Preparation Kit following the manufacture protocol (Illumina, San Diego, CA, USA) and then sequenced by Illumina NextSeq 550.
-
bioRxiv - Genomics 2023Quote: ... Libraries for RNA-seq were prepared from 1 μg of total RNA using Truseq Total RNA Library Prep Kit (Illumina) following manufacturer’s protocols ...
-
bioRxiv - Plant Biology 2023Quote: ... Plate-based RNA sample preparation was performed on the PerkinElmer Sciclone NGS robotic liquid handling system using Illumina’s TruSeq Stranded mRNA HT sample prep kit utilizing poly-A selection of mRNA following the protocol outlined by Illumina in their user guide ...
-
bioRxiv - Genomics 2023Quote: ... 1 µg RNA was converted to ribosomal depleted cDNA libraries ready for sequencing using the TruSeq Stranded Total RNA Library Prep Human/Mouse/Rat kit (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... Subsequent next-generation sequencing was performed on an Illumina MiSeq platform using the MiSeq Reagent Kit v2 (300 cycles: Illumina).
-
bioRxiv - Molecular Biology 2023Quote: ... Libraries were prepared using the Illumina TruSeq Stranded Total RNA kit with ribosomal depletion by Ribo-Zero Gold solution from Illumina according to the manufacturer’s protocol and sequenced on an Illumina HiSeq 4000 (2× 75 bp).
-
bioRxiv - Immunology 2023Quote: ... all indexed libraries were pooled with 6% PhiX spike-in DNA and sequenced using a MiSeq Reagent Nano Kit v2 (500 cycles) (Illumina) at the Fralin Genomics Sequencing Center.
-
bioRxiv - Cancer Biology 2023Quote: ... The clustering of the index-coded samples was performed on a cBot Cluster Generation System using PE Cluster Kit cBot-HS (Illumina). After cluster generation ...
-
bioRxiv - Cell Biology 2023Quote: ... Input and RNA eluted from m6A-IP were used to generate the library using TruSeq stranded mRNA sample preparation kit (Illumina). All sequencing was performed on an Illumina HiSeq 6000 according to the manufacturer’s instructions.
-
bioRxiv - Pathology 2023Quote: RNA-seq libraries were constructed from 120 RNA samples obtained from six cattle per breed at four time points at the MGX platform in Montpellier (France) using the TruSeq Stranded mRNA Library Prep Kit (Illumina) following the manufacturer’s instruction ...
-
bioRxiv - Microbiology 2023Quote: ... Sequencing was either performed using the MinION sequencer (Oxford Nanopore Technologies) or with the Nextera XT DNA Sample Preparation kit (Illumina) as described elsewhere (46 ...
-
bioRxiv - Molecular Biology 2023Quote: ... we used one lane of a NovaSeq 6000 SP Reagent Kit v1.5 (100 cycles) (Illumina, San Diego, CA, USA, 20028401) (Illumina ...
-
bioRxiv - Genomics 2022Quote: ... Clustering of index-coded samples was performed on a cBot Cluster Generation System using the TruSeq SR Cluster Kit v3-cBot-HS (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2022Quote: Libraries from primary cardiac macrophages and total myocardium as well as Schlafenlnc-deficient and control cell lines were generated using the TruSeq Stranded RNA Kit (Illumina) according to the manufacturer’s protocol ...
-
bioRxiv - Genomics 2022Quote: Small RNA libraries were prepared starting from 5 µL RNA eluate using the TruSeq Small RNA Library Prep Kit (Illumina, RS-200-0012 ...
-
bioRxiv - Developmental Biology 2023Quote: ... cDNA was synthesised from extracted RNA according to the Smart-seq2 protocol (Picelli et al., 2014) and libraries were prepared using the Nextera XT kit (Illumina). Prior to sequencing ...
-
bioRxiv - Microbiology 2023Quote: ... robotic liquid handling system using Illuminas TruSeq Stranded mRNA high throughput (HT) sample prep kit utilizing poly-A selection of mRNA following the protocol outlined by Illumina in their user guide ...
-
bioRxiv - Cell Biology 2022Quote: ... Multiplexed libraries for the 1.5 h samples were generated using the Lexogen QuantSeq 3’ mRNA-Seq Library Prep Kit and for the 6 h samples using TruSeqHT Stranded Total RNA Library Prep protocol (Illumina).
-
bioRxiv - Cell Biology 2022Quote: ... RNA samples with an RNA Integrity Number > 8 were used to prepare libraries following the standard protocol for the TruSeq Stranded mRNA library kit (Illumina) on the Illumina Neoprep automated microfluidic library prep instrument ...
-
bioRxiv - Cancer Biology 2023Quote: ... Illumina sequencing libraries were generated with the KAPA Biosystems Stranded RNA-Seq Kit[84] and sequenced using HiSeq 2000 (Illumina) with 100bp paired-end reads ...
-
bioRxiv - Cancer Biology 2023Quote: ... whole RNA were also isolated for downstream RNA sequencing and normalization for translational efficiency analysis using the TruSeq RNA Library Prep Kit v2 (Illumina).
-
bioRxiv - Cancer Biology 2023Quote: RNA-seq libraries were prepared with 0,5-1 µg of total high quality RNA collected from samples and the Illumina Stranded Total RNA Prep kit (Illumina) according to manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2023Quote: ... Spatially tagged cDNA libraries were constructed with the 10x Genomics Visium Spatial Gene Expression 3’ Library Construction V1 Kit and then sequenced on Novaseq (Illumina)
-
bioRxiv - Cancer Biology 2023Quote: ... 1 µg of cleaned RNA samples were used to generate RNA-seq libraries using the TruSeq RNA Library Prep Kit v2 (Illumina) following the manufacturer’s protocols and sequenced using the 2 x 75 bases paired-end protocol on a NextSeq550 instrument (Illumina) ...
-
bioRxiv - Cancer Biology 2023Quote: ... Nuclei were resuspended in a transposition reaction mix prepared using the Illumina Tagment DNA Enzyme and Buffer Kit (Illumina, 20034197) and incubated at 37 °C for 30 minutes on thermomixer at 1,000 rpm to allow for transposition-based DNA fragmentation and adapter ligation ...
-
bioRxiv - Genomics 2022Quote: RNA extracts were used as input for library preparation by using RNA Prep with Enrichment kit (Cat No: 20040537, Illumina). The following steps were involved in the process ...
-
bioRxiv - Immunology 2023Quote: ... Clustering of the index-coded samples were performed on a cBot cluster generation system using HiSeq PE Cluster Kit v4-cBot-HS (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Genetics 2023Quote: ... Sequencing for both input and output libraries were performed using a NextSeq Mid or High Output Kit with 150-cycles (Illumina). Additionally ...
-
bioRxiv - Developmental Biology 2022Quote: ... 1 μg of total RNA from each sample was used to generate RNA-seq libraries using TruSeq Stranded mRNA Library Preparation Kit Set A (Cat. No. RS-122-2101, Illumina) according to the manufacturer’s instruction ...
-
bioRxiv - Developmental Biology 2023Quote: ... Nuclei were mixed with 50 µl of transposition reaction mix containing Tagment DNA Enzyme 1 (Nextera DNA Library Preparation Kit, Illumina). The transposition reaction was carried out at 37°C and 600rpm for 30 min ...
-
bioRxiv - Developmental Biology 2023Quote: ... 50ng of RNA was utilized to create sequencing libraries for 75bp single end reads using the True Seq mRNA V2 Kit from Illumina, Inc ...
-
bioRxiv - Developmental Biology 2023Quote: Ribosomal RNAs were depleted from 1 µg of total RNA using TruSeq Stranded Total RNA kit Ribo-Zero components (Illumina) according to the manufacturer’ s protocol ...
-
bioRxiv - Developmental Biology 2023Quote: ... Indexed libraries were pooled and sequenced on an Illumina MiSeq using a MiSeq Reagent Nano Kit v2 (250×250; Illumina) with 10% PhiX spike-in.
-
bioRxiv - Developmental Biology 2023Quote: ... 100 cycle sequencing kit (v1.5) to a minimum depth of 50K reads per cell (Illumina Inc., San Diego, CA, USA). Base calling was done by Illumina RTA3 and output was demultiplexed and converted to FastQ format with Cell Ranger (10X Genomics ...
-
bioRxiv - Genomics 2023Quote: ... chrRNA were then subjected to library preparation using True-seq stranded total RNA library prep gold kit (Ref#220599) from Illumina using 1 μg of chrRNA ...
-
bioRxiv - Genomics 2023Quote: ... Five ng of ChIP DNA were used to prepare sequencing libraries with Illumina ChIP Sample Library Prep Kit (Illumina, USA). After end-repair and adaptor ligation ...
-
bioRxiv - Genomics 2023Quote: ... The RNA-seq libraries were subjected to two rounds of 75bp paired end sequencing on a NextSeq 550 platform using a 150-cycle kit (Illumina).
-
bioRxiv - Evolutionary Biology 2022Quote: Total DNA was isolated using the Epicentre MasterPure™ Complete DNA and RNA Purification Kit (Illumina Inc., Madison, WI, USA) including RNase digestion ...
-
bioRxiv - Cell Biology 2023Quote: ... Pools were sequenced with 75 cycle run kits (26bp Read1, 8bp Index1 and 55bp Read2) on the NextSeq 500 Sequencing System (Illumina) to $70%–80% saturation level.
-
bioRxiv - Microbiology 2023Quote: Sequencing libraries were prepared from the same DNA extracted from the individual collected in October 2010 and previously reported in [10] using the Nextera kit (Illumina) according to the manufacturer’s instructions and concentrations measured using the QuantIT kit (Molecular Probes ...
-
bioRxiv - Biochemistry 2023Quote: The clustering of the index-coded samples was performed on a cBot Cluster Generation System using TruSeq PE Cluster Kit v3-cBot-HS (Illumina) according to the manufacturer‘s instructions ...
-
bioRxiv - Neuroscience 2023Quote: ... Sequencing libraries were constructed from 300 ng of RNA per sample using the TruSeq Stranded mRNA Library Prep kit (Illumina).
-
bioRxiv - Physiology 2023Quote: ... Eighteen pM libraries were clustered in a high-output flow cell using HiSeq Cluster Kit v4 on a cBot (Illumina). After cluster generation ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... We then performed a second PCR step in which unique dual-index combinations were appended to the amplicons using the Nextera XT index kit (Illumina). Second-step PCRs were performed in a 25 μL ...