Labshake search
Citations for Illumina :
8501 - 8550 of 9619 citations for C Reactive Protein CRP ELISA Kit 1 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2019Quote: ... Pooled and purified libraries were fragmented using Nextera XT DNA Sample Preparation Kit (Illumina, Cat. Nos. FC-131-1024, FC-131-1096). Illumina sequencing indexes (provided with the SMART-Seq v4 3’ DE kit ...
-
Exploring the microbial diversity in oil-contaminated mangrove sediments using 16S rRNA metagenomicsbioRxiv - Microbiology 2019Quote: ... Paired-end sequencing libraries (2 × 300 bp) were prepared using the Illumina Nextera XT Library Preparation Kit (Illumina Inc., San Diego, CA) and sequenced on the Illumina MiSeq platform using V3 chemistry according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2019Quote: ... two samples per genotype were generated with the TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero (Illumina, RS-122-2201) and single-end sequenced (50 bp read-length ...
-
bioRxiv - Genomics 2021Quote: ... Sequencing libraries were constructed using Nextera® XT DNA Library Preparation Kits and 96 well v2 indexes (Illumina, San Diego, CA, USA). The libraries were quality checked using an Agilent 4200 TapeStation and pooled at equimolar concentrations ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... RNA sequencing libraries were prepared from the same material using the Illumina TruSeq stranded RNA-seq preparation kit (Illumina Inc., United States) following manufacturer’s instructions ...
-
bioRxiv - Genomics 2021Quote: ... Genome libraries for short-read sequencing were prepared with the TruSeq DNA PCR-Free Sample Prep Kit (Illumina, San Diego, CA, USA), and sequenced on the NextSeq 500 platform (Illumina ...
-
bioRxiv - Microbiology 2020Quote: ... Illumina sequencing adapters and dual-index barcodes were added to the purified amplicon products using limited cycle PCR and the Nextera XT Index Kit (Illumina, CA, USA). Amplicons from 96 samples and controls were pooled in equimolar amounts and the resultant libraries were purified by gel extraction and quantified (Qiagen ...
-
Enzymes degraded under high light maintain proteostasis by transcriptional regulation in ArabidopsisbioRxiv - Plant Biology 2021Quote: ... Total RNA-sequencing libraries were prepared using the TruSeq Stranded Total RNA with Ribo-Zero Plant kit (RS-122-2402, Illumina, CA, USA) as per manufacturer’s instructions but with input RNA and reaction volumes adjusted by one-third ...
-
bioRxiv - Genetics 2021Quote: ... 300 ∼ 420 ng of RNA was used for E8.5 cDNA library generation with the KAPA-Stranded mRNA-seq kit (Illumina Platforms, KR0960-v5.17).
-
bioRxiv - Developmental Biology 2020Quote: ... RNA was extracted from five biological replicates of each of the 222 and ii2 diet groups (10 samples in total) using the TruSeq Stranded mRNA-seq kit (Illumina, DA, USA). The samples were sequenced in one flowcell on the NextSeq 500 producing paired end reads of 75bp.
-
bioRxiv - Microbiology 2021Quote: Resistome enriched libraries and unenriched metagenomic libraries were sequenced on an Illumina HiSeq X Ten using a HiSeq X Ten Reagent Kit v2.5 (300 cycles) (Illumina, San Diego, CA) to obtain PE150 reads ...
-
bioRxiv - Cancer Biology 2021Quote: ... Strand-specific libraries were generated using the TruSeq Stranded mRNA samples preparation kit (illumine Inc., San Diego, RS-122-2101/2) according to manufacturer’s instructions (Illumina, part #15031047 Rev.E). Briefly ...
-
bioRxiv - Cancer Biology 2021Quote: ... RNA-seq libraries were constructed using a QuantSeq 3’mRNA-Seq Library Prep Kit (LEXOGEN, Vienna, Austria) and sequenced with the NextSeq500 (Illumina, CA, USA) to generate a minimum of two million single-end 75-bp reads ...
-
bioRxiv - Microbiology 2021Quote: ... 2 µL each of P7 and P5 of Nextera XT Index Kit v2 index primers (catalogue No. FC-131-2001 to 2004; Illumina, Cambridge, UK) were also added to each well ...
-
bioRxiv - Genetics 2021Quote: ... Next generation sequencing library preparations were constructed following the manufacturer’s protocol (NEBNext® Ultra™ DNA Library Prep Kit for Illumina®). For each sample ...
-
bioRxiv - Genomics 2021Quote: Next generation sequencing library preparations were constructed following the manufacturer’s protocol (NEBNext® Ultra™ DNA Library Prep Kit for Illumina®). The libraries were sequenced using the Illumina HiSeq instrument with PE150 configuration by Genewiz Co. ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... and cDNA was synthesized using random hexamers and reverse transcriptase (included in the NEB Next® Ultra™ RNA Library Prep Kit for Illumina). After the first-strand synthesis ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... Illumina sequencing libraries were generated for 5 αHHβHH mice and 5 αLLβHL mice using TruSeq RNA Sample Preparation Kit v2 (Illumina, San Diego, CA, USA) and sequenced on an Illumina HiSeq2500 platform ...
-
bioRxiv - Microbiology 2021Quote: Indexing of purified PCR products was performed using the Nextera XT Index kit v2 (Set D) as per manufacturer’s instruction (Illumina Inc, CA, USA). The libraries after indexing were quantified using Qubit dsDNA BR assay kit (Invitrogen ...
-
bioRxiv - Immunology 2020Quote: ... One microgram of high quality RNA (RIN>8) was used as a template for library generation using the Illumina TruSeq RNA Sample Prep Kit v2 (Illumina; CA, USA) according to the manufacturer’s protocol ...
-
bioRxiv - Cell Biology 2021Quote: ... Libraries were diluted to a final concentration of 2.8 pM in HT1 buffer (supplemented with the kit) and loaded on 75-cycle high-output flow cells (Illumina, FC-404-2005) and sequenced on a NextSeq 550 (Illumina) ...
-
bioRxiv - Cell Biology 2021Quote: ... was prepared into barcoded sequencing libraries using the TruSeq Stranded Total RNA kit with Ribo-Zero Plus rRNA Depletion (Illumina, Cambridge, UK) following manufacturer’s instructions ...
-
bioRxiv - Genomics 2021Quote: ... Libraries with 250-350 bp insert sizes were prepared using the TruSeq RNA Sample Prep Kit v2 (Illumina, San Diego, CA, USA). To obtain transcriptome profiles ...
-
bioRxiv - Genetics 2019Quote: ... 300 pg of each sample was enzymatically fragmented and indexed using a Nextera XT DNA Library Preparation Kit (Illumina FC-131-1024), and Index Kit (Illumina FC-131-1001) ...
-
bioRxiv - Genomics 2021Quote: ... ~800 ng of total RNA was depleted of rRNA using the Ribo-Zero rRNA Removal Kit (Illumina, Inc., San Diego, CA, USA), sheared ...
-
bioRxiv - Genetics 2020Quote: ... RNA fragments were reverse-transcribed to create the final cDNA libraries following the NEBNext® Ultra™ RNA Library Prep Kit (Illumina) and paired-end sequencing 150bp was performed on a Novaseq 6000 ...
-
bioRxiv - Genetics 2020Quote: ... A genome-wide analysis genotyping scan was performed in all six members of family A and in the proband of family B using the HumanCytoSNP-12 DNA Analysis BeadChip Kit (Illumina, San Diego), according to manufacturer’s instruction ...
-
bioRxiv - Cancer Biology 2021Quote: ... RNA-seq libraries were prepared using the TruSeq Stranded Total RNA prep kit with Ribo-Zero Gold to remove cytoplasmic and mitochondrial rRNA according to the manufacturer’s recommendation (Illumina, San Diego, CA). Total RNA-seq libraries were run on an Illumina NextSeq 500 sequencing instrument according to the manufacturer’s protocol ...
-
bioRxiv - Genomics 2019Quote: ... as per the manufacturer’s instructions and sequenced on an Illumina NextSeq500 machine with 13 libraries pooled at 1.8 pM using one High Output Kit v2 (Illumina #FC-404-2005) with 75 cycles single-end.
-
bioRxiv - Microbiology 2022Quote: ... Libraries were sequenced using a 150 bp paired-end NextSeq High Output V2 reagent kit (Illumina, FC-404-2004, San Diego, CA). Finally ...
-
bioRxiv - Neuroscience 2022Quote: ... PolyA+ selected libraries were prepared with the TruSeq mRNA Stranded Library Prep Kit with TruSeq UDI96 indexed adaptors (Illumina, San Diego, CA). Samples were multiplexed and sequenced on the Illumina NovaSeq 6000 S4 to produce approximately 100 million ...
-
bioRxiv - Genetics 2022Quote: ... to approximately 450 bp inserts followed by library preparation using the Seqlab TruSeq Nano DNA HT kit (20000903, Illumina, San Diego, USA). Library preparation was performed according to manufacturer’s instructions which included end repair ...
-
bioRxiv - Genetics 2022Quote: ... Approximately 1 µg of total RNA were used to prepare the small RNA library according to the protocol of TruSeq Small RNA Sample Prep Kits (Illumina, San Diego). Then the single-end sequencing 50bp was performed on an Illumina Hiseq 2500 at LC Sciences (Hangzhou ...
-
bioRxiv - Cancer Biology 2022Quote: ... using MiSeq V2 300 cycle reagent kit after the amplified library was purified with AMPure XP beads (Beckman Coulter, CA, USA) (Illumina, CA, USA) (10).
-
bioRxiv - Bioengineering 2022Quote: ... the organoid was then resuspended in a direct permeabilization/tagmentation mastermix (25μl TD buffer (from Illumina Nextera XT DNA Library Prep Kit), 2.5μl Tn5 ...
-
bioRxiv - Cancer Biology 2022Quote: ... The libraries were prepared from total RNA by using the TruSeq Stranded mRNA Library Prep kit according to the manufacturer’s instructions (Illumina, San Diego, CA). The libraries were analyzed for insert size distribution by using a 2100 BioAnalyzer High Sensitivity kit (Agilent) ...
-
bioRxiv - Genomics 2022Quote: ... The construction of libraries was performed with Illumina preparation kits (Table S1) following the manufacturer’s recommendations (Illumina Inc., San Diego, CA, USA). The Nextera DNA Prep kit and Illumina DNA Prep were used for WGS ...
-
bioRxiv - Plant Biology 2022Quote: ... RNA-seq libraries were constructed by the POPS platform (IPS2) using the TruSeq Stranded mRNA library prep kit (Illumina®, California, U.S.A.) according to the supplier’s instructions ...
-
bioRxiv - Microbiology 2022Quote: ... DNA libraries were prepared according to the manufacturer’s protocol using the Nextera DNA Flex Library Preparation Kit (Illumina, San Diego, CA, USA). Library preparation and bead clean-up was undertaken with the Mantis® Liquid Handler (Formulatrix ...
-
bioRxiv - Microbiology 2022Quote: ... The same amount of the seven purified 3-cycle PCR products were further amplified using Platinum SuperFi II and the index primers from Nextera XT Index Kit v2 (Illumina cat. 15052163). The PCR products were purified using 1.8× beads ...
-
bioRxiv - Genomics 2022Quote: Genomic libraries were prepared from 1 ng of high-quality genomic DNA using the Nextera DNA Flex Library Prep kit (now called Illumina DNA Prep, Illumina C.A., USA), following the manufacturer instructions ...
-
bioRxiv - Microbiology 2022Quote: We prepared cDNA sequencing libraries for the transcriptome samples using the TruSeq RNA Library Prep Kit v2 (Illumina, San Diego, CA, USA). Paired-end fragment reads were generated on an Illumina NextSeq sequencer using TG NextSeq® 500/550 High Output Kit v2 (300 cycles) ...
-
bioRxiv - Synthetic Biology 2022Quote: ... pH 8.5 and sequenced on an Illumina NextSeq 550 following the manufacturer’s instructions using a NextSeq 500/550 Mid or High Output Kit (Illumina, 20024904 or 20024907), or on an Illumina NextSeq 1000 following the manufacturer’s instructions using NextSeq P2 v3 kits (Illumina ...
-
bioRxiv - Plant Biology 2022Quote: ... Five micrograms of total RNA from each sample were used to construct an RNA-Seq library by using the TruSeq RNA Sample Preparation Kit according to the manufacturer’s instructions (Illumina, San Diego, CA). A total of 72 libraries (Table S2 ...
-
bioRxiv - Molecular Biology 2023Quote: ... 100 000 nuclei were subjected to Tn5 transposition reaction using 2.5 μl TDE1 from Nextera DNA Library Prep Kit (Illumina, #FC-121-1030). After adding the transposition reaction mix ...
-
bioRxiv - Plant Biology 2022Quote: ... Total RNAs from WT and e2fabc at 9 DAG were used for construction of cDNA libraries using the TruSeq RNA Library Preparation Kit v2 (Illumina, United States) according to the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2022Quote: ... Amplified cDNA was fragmented and appended with dual-indexed barcodes using Illumina Nextera XT DNA Library Prep kits (Illumina, San Diego, CA). Libraries were validated on an Agilent 4200 TapeStation (Agilent Technologies ...
-
bioRxiv - Molecular Biology 2022Quote: ... Single-read sequencing was performed on a NovaSeq 6000 device using an S2 Reagent kit (100 cycles) according to the manufacturer’s instructions (Illumina Inc., CA, USA).
-
bioRxiv - Microbiology 2022Quote: ... enteroids were suspended in RNALater and RNA was isolated using Tru-Seq total RNA Sample Preparation v2 kit (Illumina, Great Abingdon, UK) according to manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2022Quote: ... Complementary DNA libraries from total RNA samples were prepared with Illumina TruSeq RNA preparation kits according to the manufacturer’s instructions (Illumina, San Diego, CA). RNA integrity was assessed using an Agilent 2100 Bioanalyzer (Santa Clara ...