Labshake search
Citations for Illumina :
801 - 850 of 3798 citations for RNA Binding Motif Protein 45 RBM45 Antibody since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2022Quote: ... We performed 150 bp paired-end RNA sequencing on all samples that yielded RNA using a NovaSeq 6000 (Illumina, Inc.).
-
bioRxiv - Microbiology 2022Quote: ... a ribosomal RNA depletion was performed on the total RNA using the Ribo-Zero rRNA Removal Kit (Gram-Positive Bacteria) (Illumina). Bar-coded RNA libraries were generated according to the manufacturers’ protocols using the Ion Total RNA-Seq Kit v2 and the Ion Xpress RNA-Seq barcoding kit (Thermo Fisher Scientific) ...
-
bioRxiv - Molecular Biology 2022Quote: Preparation of samples for RNA-Seq analysis was performed using the TruSeq RNA Sample Preparation Kit (Illumina, San Diego, CA). Briefly ...
-
bioRxiv - Plant Biology 2022Quote: ... the TruSeq RNA protocol v2 was used for the construction of TruSeq RNA libraries on PerkinElmer Sciclone (Illumina 15026495 Rev.F). After adaptor ligation ...
-
bioRxiv - Systems Biology 2022Quote: ... Sequencing libraries for the long RNA fraction were constructed using the Illumina TruSeq Stranded Total RNA Sample Preparation Kit with Ribo-Zero ribosomal RNA reduction chemistry (Illumina) in accordance with the manufacturer’s instructions with the exception that for later batches multiple Ribo-Zero washes were used to reduce the amount of rRNA sequenced ...
-
bioRxiv - Neuroscience 2022Quote: ... 500ng-1μg of total RNA per sample was enriched for polyadenylated RNA and prepared for RNA sequencing using the TruSeq Stranded mRNA Library Prep Kit (Illumina) per manufacturer instructions ...
-
bioRxiv - Genomics 2022Quote: ... Nuclear and cytoplasmic RNA was used separately as input for Illumina’s TruSeq stranded total RNA library preparation kit with Ribo-Zero (Illumina, USA), and the resulting cDNA libraries underwent 100bp paired end sequencing (Illumina HiSeq4000) ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5 μg of total RNA was used as an input material for library preparation using TruSeq RNA Sample Preparation Kit v2 (Illumina). Library size was confirmed using a Fragment Analyzer (Advanced Analytical Technologies) ...
-
bioRxiv - Neuroscience 2022Quote: ... The Genomics Facility at the Cornell Institute of Biotechnology used 500ng of RNA/sample for 3’RNA library preparation with the Lexogen QuantSeq 3’ mRNA-Seq Library Prep Kit FWD (Illumina), sequenced libraries on an Illumina NextSeq500 sequencer (single end 1×86bp) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Strand-specific libraries were generated from 500 ng total RNA using the TruSeq Stranded Total RNA Library Prep Kit (Illumina). cDNA libraries were single-end sequenced (50bp ...
-
bioRxiv - Plant Biology 2022Quote: PolyA-RNA libraries from St Pierre tomato were generated from 500 ng of total RNA using Truseq Stranded mRNA kit (Illumina). Libraries were sequenced on a NextSeq 500 platform (Illumina ...
-
bioRxiv - Molecular Biology 2022Quote: ... RNA-Seq libraries were prepared from total RNA using the TruSeq Stranded mRNA Library Prep Kit (Illumina, San Diego, CA). High-throughput sequencing was performed at UCLA Technology Center for Genomics & Bioinformatics using the Illumina HiSeq 4000 platform (paired-end 75 bp reads) ...
-
bioRxiv - Molecular Biology 2023Quote: Libraries were prepared with total RNAs using TruSeq Stranded Total RNA Library Prep Gold Kit from Illumina (San Diego, California) according to the manufacturer ...
-
bioRxiv - Plant Biology 2023Quote: ... cDNA libraries were constructed from 1 μg/sample of total RNA using library preparation kits (NEBNext Ultra II RNA Library Prep Kit for Illumina 7770L ...
-
bioRxiv - Genomics 2023Quote: ... The RNA was used for preparing the library using TruSeq Stranded Total RNA Library Preparation kit (Illumina Inc., CA, USA) with Ribo-zero Plant workflow and sequenced on Illumina NovaSeq 6000 instrument for generated 150 bp paired-end reads.
-
bioRxiv - Physiology 2023Quote: ... Total RNA (500ng) was used to initiate the Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus (Illumina 20040525) library preparation protocol ...
-
bioRxiv - Neuroscience 2023Quote: ... Paired-end strand-specific sequencing libraries were prepared from 40 ng total RNA using the TruSeq Stranded Total RNA Ribo-Zero Gold Library Preparation kit (Illumina). Following quality control on a BioAnalyzer (Agilent) ...
-
bioRxiv - Microbiology 2023Quote: ... was depleted and cDNA libraries were prepared from 100 ng total RNA by Stranded Total RNA Prep Ligation with Ribo-Zero Plus (Illumina). The quantity and quality of the prepared library were analyzed by the Qubit dsDNA BR Assay Kit and the Agilent 2100 Bioanalyzer using a DNA 1000 Kit ...
-
bioRxiv - Genomics 2023Quote: ... Preparation of samples for RNA-Seq analysis was performed using the TruSeq RNA Sample Preparation Kit (Illumina, San Diego, CA). Briefly ...
-
bioRxiv - Microbiology 2023Quote: ... Ribosomal RNA was depleted and libraries were constructed using the Illumina Stranded Total RNA Prep with Ribo-Zero Plus (Illumina) using 100 ng of RNA input ...
-
bioRxiv - Physiology 2023Quote: RNA-seq libraries were prepared from total RNA using the TruSeq Stranded mRNA kit (Illumina, Inc., San Diego, CA, USA). Library size distribution was validated using an Agilent 4200 TapeStation (Agilent Technologies ...
-
bioRxiv - Cancer Biology 2023Quote: ... whole RNA were also isolated for downstream RNA sequencing and normalization for translational efficiency analysis using the TruSeq RNA Library Prep Kit v2 (Illumina).
-
bioRxiv - Cancer Biology 2023Quote: RNA-seq libraries were prepared with 0,5-1 µg of total high quality RNA collected from samples and the Illumina Stranded Total RNA Prep kit (Illumina) according to manufacturer’s instructions ...
-
bioRxiv - Genomics 2022Quote: RNA extracts were used as input for library preparation by using RNA Prep with Enrichment kit (Cat No: 20040537, Illumina). The following steps were involved in the process ...
-
bioRxiv - Biochemistry 2023Quote: ... Libraries from randomly primed total RNA were prepared using the xGen NGS RNA (Integrated DNA Technologies) kit for HEK293 and the Nextera XT (Illumina) kit for E ...
-
bioRxiv - Genomics 2023Quote: ... Strand-specific RNA-SEQ libraries were prepared using an oligo-dT based RNA-SEQ library protocol (Illumina/NEB/Kapa provided). Library quality and quantity was assessed using the Agilent bio-analyzer and libraries were sequenced using an Illumina NovaSeq 6000.
-
bioRxiv - Molecular Biology 2023Quote: ... rRNA was removed from the purified RNA using Ribo-Zero Gold rRNA Removal Kit accompanied by TruSeq Stranded Total RNA Kit (Illumina). RNA was then reverse-transcribed for 30[min at 50°C using ProtoScript II (New England Biolabs ...
-
bioRxiv - Bioengineering 2023Quote: RNA was extracted from the spinal cord and prepared for RNA sequencing with TruSeq Standard mRNA sample Prep Kit (Illumina). Deep sequencing was performed on the Illumina NovaSeq6000 ...
-
bioRxiv - Microbiology 2023Quote: ... RNA extracts from the microneutralisation and TCID50 experiments were used as input into the RNA Prep with Enrichment kit (Illumina Inc ...
-
bioRxiv - Genomics 2023Quote: ... Roughly 15% of each lysate was kept for RNA isolation and used for RNA-seq of poly(A)-enriched fractions on a HiSeq2500 platform (Illumina). After sequencing of both Ribo-and mRNA-seq libraries ...
-
bioRxiv - Cancer Biology 2023Quote: ... 100 ng DNase treated RNA was used to generate ribo-minus treated total RNA stranded libraries using Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus kit (Illumina) according to manufactures’ instructions ...
-
bioRxiv - Plant Biology 2023Quote: ... 250ng of total RNA from mature pollen and 1000 nanograms of total RNA from inflorescences or leaf tissues were used for RNA-seq library preparation with TruSeq Stranded mRNA kit (Illumina). The final library was sequenced on Illumina NovaSeq 6000 or HiSeq 4000 instruments.
-
bioRxiv - Molecular Biology 2023Quote: Dual indexed FFPE libraries were constructed with a 500 ng input of total RNA utilizing the TruSeq Stranded Total RNA Library Construction riboGold kit (Illumina). Two pools of five samples each were pooled at an equimolar ratio yielding ∼900ng (Pool 1 ...
-
bioRxiv - Cancer Biology 2023Quote: ... RNA samples were sequenced using Truseq Stranded Total RNA Library Prep Kit and Illumina HiSeq4000 PE100 (Illumina, San Diego, CA) by the Genome Quebec Innovation Centre ...
-
bioRxiv - Molecular Biology 2023Quote: ... Sequencing libraries were prepared from purified RNA for two or three biological replicates using TruSeq RNA Library Prep kit v2 (Illumina). Libraries were sequenced on the Illumina HiSeq 2500 or Illumina NovaSeq.
-
bioRxiv - Plant Biology 2023Quote: ... The RNAseq library for each sample was prepared with a 1250 ng of total RNA using the TruSeq RNA Sample Preparation kit (Illumina) according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2024Quote: ... The RNA was fragmented and transformed into double-stranded cDNA libraries using the TruSeq RNA Sample Preparation Kit v2 (Illumina), following manufacturer’s protocol ...
-
bioRxiv - Microbiology 2023Quote: ... isolated RNA samples were deprived of ribosomal RNA with Illumina Ribo-Zero Plus rRNA Depletion Kit (Illumina, San Diego, CA) and processed into a cDNA library for Illumina with the NEBNext Ultra II Directional RNA Library Prep Kit for Illumina (New England Biolabs) ...
-
bioRxiv - Neuroscience 2024Quote: ... RNA was analyzed using a BioAnalyzer and samples with 8.7-10.0 RNA integrity number values were used for library preparation using the Illumina TruSeq RNA Sample Preparation v2 Guide (Illumina). Libraries were sequenced on an Illumina NextSeq 500 as 42bp paired-end reads (PE42) ...
-
bioRxiv - Physiology 2023Quote: ... 1 µg of total RNA was used as input for Truseq Stranded total RNA library preparation following the low sample protocol (Illumina). Sequencing was performed on the NextSeq2000 instrument (Illumina ...
-
bioRxiv - Plant Biology 2023Quote: ... value of 8 was employed for RNA-Seq library construction using the TruSeq Stranded Total RNA Library Prep Plant kit (Illumina). Hisat2 (Kim et al. ...
-
bioRxiv - Neuroscience 2024Quote: ... 250 ng of total RNA per sample was used for library construction with the TruSeq RNA Sample Prep Kit (Illumina) and pair-end sequenced using the Illumina HiSeq 2500 instrument ...
-
bioRxiv - Cell Biology 2024Quote: ... 100 ng of DNase-treated total RNA was used for library preparation with the Illumina Stranded Total RNA Prep Ligation with Ribo- Zero Plus kit (Illumina). The libraries were evaluated using an Agilent High-Sensitivity DNA Kit (Agilent ...
-
bioRxiv - Molecular Biology 2024Quote: ... Extracted total RNA was send to Azenta Life Sciences for library preparation (sRNA: NEBNext Small RNA Library Prep Set for Illumina; mRNA ...
-
bioRxiv - Molecular Biology 2024Quote: ... Extracted total RNA was send to Azenta Life Sciences for library preparation (sRNA: NEBNext Small RNA Library Prep Set for Illumina; mRNA: NEBNext Ultra II RNA Library Prep Kit for Illumina) and paired-end Illumina sequencing (NovaSeq 2×150bp).
-
bioRxiv - Cancer Biology 2024Quote: ... RNA-seq libraries for the cell lines and the CLL RNA were prepared using the TruSeq-stranded-total RNA SamplePrep kit (Illumina) according to the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2024Quote: ... RNA samples were then subjected to RNA-Seq library preparation following the stranded total RNA prep Ligation with Ribo-Zero plus kit (Illumina). After depletion of the rRNA by hybridization with directed probes ...
-
bioRxiv - Cancer Biology 2024Quote: Libraries were constructed from 500 ng of total RNAs isolated from 4T1 (scrambled vs Tlr7 shRNA) using the TruSeq RNA Library Prep Kit (Illumina). Constructed libraries were sequenced using Illumina NextSeq (High Output ...
-
bioRxiv - Cancer Biology 2024Quote: PolyA mRNA was enriched from total RNA and constructed into a library for RNA-seq using the Stranded Total RNA Prep with Ribo-Zero Plus Kit (Illumina). cDNA libraries were sequenced using paired-end 150bp on the Illumina NovaSeq 6000 platform at 50 million reads per samples ...
-
bioRxiv - Cancer Biology 2024Quote: ... RNA-seq libraries were prepared from total RNA using the TruSeq Stranded mRNA kit (Illumina, Inc., San Diego, CA, USA). Sequencing was performed using an Illumina NovaSeq 6000 employing a paired-end ...