Labshake search
Citations for Illumina :
651 - 700 of 814 citations for 3 1 Phenylethylamino propane 1 thiol since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2024Quote: ... Library generation for 10x Chromium analysis was performed following the Chromium Single Cell 3′ Reagents Kits (10x Genomics) and sequenced on an Hiseq4000 (Illumina), to achieve an average of ∼44,000 reads per cell and ∼11,000 cells per sample ...
-
bioRxiv - Cancer Biology 2024Quote: ... H146 and H69) and 3 NSCLC lines (H838, H1944 and A549) was subjected to methylation analysis using the Infinium MethylationEPIC BeadChips (Illumina) allowing the simultaneous quantitative measurement of the methylation status at 865,918 CpG sites ...
-
bioRxiv - Genomics 2021Quote: ... Total RNA (1 μg) from each sample was used for NEBNext PolyA selection and Ultra Directional RNA Library preparation (Illumina, E7490, E7420). Prepared libraries were sequenced using 2×150 bp paired-end read chemistry on an Illumina HiSeq 4000 platform.
-
bioRxiv - Molecular Biology 2021Quote: ... 1 ug of treated RNA was then input into the Illumina TruSeq Small RNA Library Preparation Kit (Illumina; Cat #: RS-200-0012) with 11 cycles of PCR amplification ...
-
bioRxiv - Genomics 2020Quote: ... Samples were prepared for sequencing using 1 ug of genomic DNA following the TruSeq PCR free kit protocol (Illumina, FC-121-3001). Resulting libraries were quality checked on an Agilent DNA 1000 bioanalyzer (Agilent Technologies ...
-
bioRxiv - Plant Biology 2020Quote: 42 RNA samples from experiment 1 were used for mRNA-Seq library preparation using the TruSeq Stranded mRNA Library Prep Kit (Illumina, CA, USA). Libraries were multiplexed and single-end 100 nt RNA-Seq was performed on a Novaseq 6000 at the GIGA Center (University of Liege ...
-
bioRxiv - Genomics 2022Quote: ... a library was prepared from 1 μg of genomic DNA and a TruSeq DNA PCR-free Sample Preparation Kit (Illumina, CA, USA). Paired-end (151 bp per read ...
-
bioRxiv - Genomics 2022Quote: ... Libraries were prepared with 1 μg of total RNA for each sample using a TruSeq Stranded mRNA Sample Prep Kit (Illumina, CA, USA). Paired-end sequencing (151 bp ...
-
bioRxiv - Microbiology 2022Quote: ... The V4 region of the 16S rRNA gene was amplified from 1 or 7μl DNA and sequenced with a MiSeq (Illumina, San Diego, CA) using the 500 cycle MiSeq Reagent Kit ...
-
bioRxiv - Cell Biology 2020Quote: ... cDNA was diluted 1:15 and subsequently tagmented and amplified for 12 cycles using the Nextera XT DNA Library Preparation Kit (Illumina FC-131). Individual libraries were QC’d by Qubit and Agilent Bioanalyzer ...
-
bioRxiv - Genetics 2020Quote: ... One sequencing experiment (Experiment 1) was performed according to the manufacturer’s directions for the TruSeq Small RNA Sample Preparation Kit (Illumina, RS-200-0012). The protocol was adapted to incorporate a 2S blocking DNA oligo for removal of prevalent Drosophila small ribosomal RNA from the sequencing library [67] ...
-
bioRxiv - Genomics 2020Quote: ... The cDNA library was generated from 1 µg of total RNA using TruSeq RNA Sample Prep Kit (Illumina, San Diego, CA, USA) following manufacturer’s protocols ...
-
bioRxiv - Immunology 2020Quote: ... The Illumina RNA-seq cDNA library was prepared using 1 μg of RNA from each sample and TruSeq V2 kits (Illumina, CA, USA), with reduced RNA fragmentation time (3 minutes ...
-
bioRxiv - Plant Biology 2021Quote: ... Libraries for RNA-Seq were prepared from 1 µg of total RNAs with the TruSeq Stranded mRNA Library Prep Kit (Illumina, CA, USA), multiplexed and sequenced in two runs with an Illumina NextSeq500 device (high throughput mode ...
-
bioRxiv - Immunology 2022Quote: ... Amplified (1 ng) cDNA was used to generate barcoded libraries using the Nextera XT DNA library preparation kit (Illumina, San Diego, CA). The size of the libraries was checked using the Agilent 2100 Bioanalyzer High Sensitivity DNA chip and their concentration was determined using the Qubit® fluorometer (ThermoFisher Scientific ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1 µg of total RNA was used as input for the TruSeq RNA Library Prep Kit v2 (Illumina, Inc., San Diego, CA) and the manufacturer’s protocol was followed ...
-
bioRxiv - Neuroscience 2024Quote: ... Illumina Sequencing libraries were prepared using the TruSeq low sample protocol from 1 µg of total RNA (Illumina, San Diego, CA, USA). The resulting libraries were sequenced in paired-end mode ...
-
bioRxiv - Genomics 2024Quote: DNA concentration was normalized to 1 ng/μl and subjected to library preparation using Nextera XT DNA Library Preparation Kit (Illumina, CA, USA) according to the manufacturer’s instructions and sequenced with NextSeq550 using Mid Output Kit v2.5 (300 cycles ...
-
bioRxiv - Genomics 2023Quote: 1 ng of genomic DNA from each sample was used with Illumina MiSeq Nextera XT DNA Library Preparation Kit (Illumina, Inc., USA), the paired-end library was constructed with an insert (500 bp ...
-
bioRxiv - Systems Biology 2023Quote: ... 0.5 µL of universal primer and 0.5 µL of index primer (each at 0.5µM concentration; NEBNext multiplex oligos for Illumina index primers set 1 E7335). This mix has been amplified for 15 cycles (same amplification conditions as before) ...
-
bioRxiv - Immunology 2023Quote: ... and sequencing was performed in a 1×100 bp single-read format using a NovaSeq 6000 v1.5 100-cycle reagent kit (Illumina, Cat no. 20028316). Base calling was performed with Illumina Real Time Analysis (RTA ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... and g2997a) at the forward primer binding site used in the ‘round 1 PCR’ step below (the step attaching partial Illumina sequencing adaptors), thus excluding PCR amplification of the competitor viruses during sequencing library preparation such that only the library viruses ...
-
bioRxiv - Genomics 2022Quote: ... we generated a combination of noisy ONT sequencing (MinION R.9.4.1 flow cells with the LSK-109 ligation library prep kit) and Illumina sequencing (PE 150 bp, ∼49x coverage; Illumina NovaSeq 6000). Based on published ONT benchmarking (https://nanoporetech.com/accuracy) ...
-
Lysyl oxidase regulates epithelial differentiation and barrier integrity in eosinophilic esophagitisbioRxiv - Cell Biology 2023Quote: ... Sequencing libraries were constructed from total RNA (1 μg) using a TruSeq Stranded mRNA Library Prep (Illumina Inc., San Diego, CA, USA). RNA sequencing was performed on Illumina HiSeq2000 platform ...
-
bioRxiv - Neuroscience 2023Quote: ... Female and male samples after MR1 were sequenced (single-end reads, 1×75 nt) with Illumina NextSeq 500 (Illumina, San Diego, USA). Female samples after MR2 were sequenced (single-end reads ...
-
bioRxiv - Genetics 2023Quote: ... 10 ng of amplicon DNA from PCR reaction 1 was combined with 10 µL of Nextera adapter index primers (Illumina Cat#20027213) and 25 µL Kapa HiFi Hotstart ReadyMix ...
-
bioRxiv - Microbiology 2024Quote: Indexed sequencing libraries were generated from 1 ng genomic DNA using Nextera XT DNA Library Preparation Kit (Illumina, San Diego, CA, USA) following the protocol of the manufacturer ...
-
bioRxiv - Genomics 2024Quote: ... Total RNA-seq libraries were generated from 1 μg of DNase-treated RNA using the TruSeq Stranded total RNA library preparation kit (Illumina, Cat# 15031048) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2024Quote: ... Sequencing libraries for Δ2 and Δ3 lines were prepared with 1 μg of gDNA per sample using the TruSeq® DNA PCR-Free Low-Throughput Library Prep Kit (Illumina, 20015962) according to the manufacturer’s directions ...
-
bioRxiv - Immunology 2024Quote: ... cDNA was diluted to an average of 200 pg/µl and 100 pg cDNA from each cell was tagmented by adding 1 µl TD and 0.5 µl ATM from a Nextera XT DNA Library Preparation Kit (Illumina: FC-131-1096) to 0.5 µl diluted cDNA in each well of a fresh 384-well plate ...
-
bioRxiv - Systems Biology 2024Quote: ... All libraries were dual-indexed with 8 nucleotide indexes using NEBNext® Multiplex Oligos for Illumina® (Index Primers Set 1) and were sequenced on NextSeq 2000 (Illumina) either by 2×150bp or 2×50bp configuration.
-
bioRxiv - Genomics 2024Quote: ... and 1 μL of TAE polymerase (TruePrep® DNA Library Prep Kit V2 for Illumina®, Cat. no. TD501-02, Vazyme Biotech). PCR thermocycling was carried out in Biometra Tone 96G thermocyclers (Analytik Jena) ...
-
bioRxiv - Cell Biology 2020Quote: ... an oligonucleotide containing the Illumina P7 adaptor sequence was ligated to the 3’ end of the single stranded LAM PCR fragments using Circligase (Epicentre/Illumina, #CL9025K). A P5 adaptor was added by PCR ...
-
bioRxiv - Neuroscience 2020Quote: ... Sequencing libraries (1.3 nM) were chemically denatured and applied to an Illumina NovaSeq flow cell using the NovaSeq XP chemistry workflow (Illumina-20021664). Following transfer of the flowcell to an Illumina NovaSeq instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... The cell solutions were immediately transferred to ice and transported to the Wellcome Trust Centre for Human Genetics (WTCHG) for scRNAseq via 10x genomics chromium (10x genomics, US) (Single Cell 3’ v3) and Illumina hiseq 4000 (Illumina, US). This approach achieved 66-72K mean reads per cell and a sequencing depth of 53-55% per cell before filtering.
-
bioRxiv - Molecular Biology 2020Quote: ... RNA was extracted and sequence reads (100 bp paired-end) were generated with Illumina TruSeq high output version 3 chemistry on a HiSeq 2500 (Illumina, Inc.) at NRC-Plant Biotechnology Institute (NRC-PBI) ...
-
bioRxiv - Cancer Biology 2020Quote: ... TN5 tagmentation and library amplification realized 3’end fragments by Nextera XT DNA Sample Preparation Kit (Illumina, Cat#FC-131-1024) according to the manufacturer’s instructions while P5_TSO and Nextera_N7xx took the place of the custom primers ...
-
bioRxiv - Developmental Biology 2022Quote: ... 500 ng of total RNA were used as input for QuantSeq (QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina; Lexogen) following the autoQuantSeq automated workflow ...
-
bioRxiv - Neuroscience 2020Quote: ... Samples were processed according to the standard 10x Chromium 3’ workflow and pooled before sequencing over two lanes (Illumina HiSeq 4000).
-
bioRxiv - Cancer Biology 2020Quote: ... 500 ng alkylated RNA was used and prepared with a commercially available kit (QuantSeq 3′ mRNA-Seq Library Prep Kit FWD for Illumina and PCR Add-on Kit for Illumina, Lexogen). Sequencing was performed on an Illumina NovaSeq SP platform in 100bp-single-read mode.
-
bioRxiv - Genomics 2021Quote: ... and ligated to custom CpG-free annealed adapters (Oligo 3 - Custom CpG-free P7 adapter and Oligo 4 - Custom CpG-free P5 adapter; annealed according to the standard Illumina protocol). The adapter-ligated gDNA was purified and amplified in 20 reactions using KAPA HiFi master mix (Roche ...
-
bioRxiv - Genomics 2021Quote: ... and 1µM Dexamethasone or 0.1% ethanol for 3 hours. Transposition was performed using the OmniATAC protocol (Corces et al. 2017) and the tagment DNA TDE1 enzyme (Illumina, 20034197). DNA was purified using the MinElute PCR purification kit (Qiagen) ...
-
bioRxiv - Cell Biology 2022Quote: The input samples were submitted to the Washington University Genome Technology Access Center to obtain and sequence the cDNA libraries (10XGenomics, 3’v3.1; Illumina NovaSeq S4) according to established protocols ...
-
bioRxiv - Molecular Biology 2022Quote: ... 1.5 μl of PCR 1 were used as template for PCR 2 (14 cycles) and used forward primers 5’-AATGATACGGCGACCACCGAGATCTACAC-NNNNNNNN-ACACTCTTTCCCTACACGAC-3’ (compatible to Illumina i5) and reverse primers 5’-CAAGCAGAAGACGGCATACGAGAT-NNNNNNNN-GTGACTGGAGTTCAGACGTG-3’ (compatible to Illumina i7) ...
-
bioRxiv - Immunology 2024Quote: ... 2024) using the command CreateSeuratObject with the following parameters: min.cells = 3 and either min.features = 200 (for Illumina reads from MBC gate) or min.features = 100 (for the Oxford Nanopore reads from the ASC gate) ...
-
bioRxiv - Molecular Biology 2023Quote: ... 1 x 105 mESCs and 5 x 104 S2 cells were resuspended in Tagment DNA Buffer and treated with 3 µL TDE1 Tagment DNA Enzyme (Illumina 20034197). After thorough mixing ...
-
bioRxiv - Genomics 2023Quote: For all tandem repeat identification and quantification we used DNA sequences from 2,504 individuals from the Phase 3 of the 1,000 Genomes Project (∼30x coverage Illumina short-read data) (Byrska-Bishop et al ...
-
bioRxiv - Genomics 2023Quote: ... 200ng alkylated RNA were used as input for generating 3’-end mRNA sequencing libraries using a commercially available kit (QuantSeq 3ʹ mRNA-Seq Library Prep Kit FWD for Illumina, Lexogen).
-
bioRxiv - Genomics 2024Quote: ... we further pooled the hybrid selection into 3 “super pools.” 2) The hybrid selected libraries were sequenced on a NovaSeq 6000 (Illumina, 20012850) with a S1 Reagent Kit v1.5 (200 cycles ...
-
bioRxiv - Cancer Biology 2024Quote: ... Collected single cells were placed on ice and further processed using the Chromium™ Single Cell 3’ Solution (10x Genomics) and sequenced on a NovaSeq 6000 (Illumina) with Illumina 3’ v3.1-paired end chemistry ...