bioRxiv - Genetics 2021Quote: ... Libraries for genome sequencing were constructed with dual indexing using 0.5-2.5 ng per reaction using a Nextera XT kit (Illumina). The libraries were multiplexed and sequenced on an Illumina HiSeq 2500 v4 or NextSeq sequencer using paired end 125 bp output ...
-
bioRxiv - Genomics 2021Quote: Pooled PCR products were subjected to multiplex next-generation sequencing (NGS) using the MiSeq Reagent Kit v2 (Illumina) or the NextSeq 500/550 v2 Reagent Kit (Illumina) ...
-
bioRxiv - Cancer Biology 2021Quote: ... cDNA libraries were generated from 200 ng total RNA using a TruSeq stranded mRNA library preparation kit (Illumina). The resultant libraries were sequenced on NextSeq550 (Illumina ...
-
bioRxiv - Biochemistry 2021Quote: ... 150 ng of sheared fragments was used as input for the TruSeq Nano DNA Library Prep Kit (Illumina). Illumina libraries were prepared following the manufacturer’s protocol with one modification to yield a narrow fragment distribution optimized for 150 bp inserts by using a ratio of 5.4 parts of sample purification beads to one part of water (135 μl SPB + 25 μl nuclease-free H2O ...
-
bioRxiv - Cancer Biology 2021Quote: ... Samples were diluted to 0.2 ng/μl and tagmented with the Nextera XT DNA Library Preparation Kit (Illumina). Samples were sequenced as previously described (18) ...
-
bioRxiv - Genetics 2021Quote: ... Multiplexed NGS libraries were prepared using the TruSeq PCR Free kit according to the manufacturer’s instructions (20015963, Illumina). The obtained libraries were sequenced using a Miseq 600 cycle kit to generate 150 bp and 300 bp paired-end reads to a depth of approximately 5-20X coverage ...
-
bioRxiv - Synthetic Biology 2022Quote: ... normalized to 20 ng/μL and sent to Genewiz for Amplicon-EZ sequencing service (Illumina HiSeq 2×150). This service typically returns 40,000 sequences however in some cases fewer than 40,000 sequences were returned ...
-
bioRxiv - Systems Biology 2022Quote: ... 1 ng of cDNA was “tagmented” and bar coded using a Nextera XT DNA Sample Preparation Kit (Illumina). The final libraries were purified using AmPure XP magnetic beads (Beckman Coulter ...
-
bioRxiv - Microbiology 2023Quote: ... Illumina paired[end next-generation sequencing (NGS) was then performed using a 500-cycle Rapid Run kit (Illumina) on a Hiseq2500 sequencer operated by Genewiz (Leipzig ...
-
bioRxiv - Systems Biology 2023Quote: ... next-generation sequencing (NGS) was performed using NextSeq 500/550 high output v2 kit (150 cycles) (Illumina, USA) to obtain 800 x 106 paired reads per pool (50 x 106 paired reads per sample) ...
-
bioRxiv - Cell Biology 2023Quote: ... Stranded libraries were prepared from 500 ng total RNA input with poly-A+ selection (TruSeq Stranded mRNA, Illumina). Final library size and concentration were assessed (Qubit ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... libraries were produced from 50 ng of DNA with the Nextera XT DNA Sample Preparation Kit (Illumina, Germany) according to the manufacturer’s protocol ...
-
bioRxiv - Systems Biology 2023Quote: Sequencing libraries were prepared by tagmenting 10 ng WTA DNA with Nextera XT kit (Illumina #FC-131-1024). Indexing PCR was primed with a nextera i7 index primer (e.g ...
-
bioRxiv - Cancer Biology 2023Quote: ... NGS was performed at the Tumour Profiling Unit of the Institute of Cancer Research using NovaSeq 6000 (Illumina). 150 pair-end reads and 15% of PhiX was considered and approximately 5000 reads per time-point was aimed.
-
bioRxiv - Immunology 2024Quote: ... RNA-seq libraries were prepared by using 200 ng total RNA with TruSeq RNA sample prep kit (Illumina). Oligo(dT)-enriched mRNAs were fragmented randomly with fragmentation buffer ...
-
bioRxiv - Genomics 2023Quote: ... DNA libraries were constructed using the NGS Nextera FLEX DNA library preparation kit (Illumina Inc., San Diego, CA) according to the manufacturer’s protocol ...
-
bioRxiv - Cancer Biology 2023Quote: ... RNA libraries were generated from 150 ng of RNA using Illumina’s TruSeq Stranded mRNA Sample Prep Kit (Illumina). Libraries were pooled and single end sequenced (1×75 ...
-
bioRxiv - Neuroscience 2023Quote: ... 1 ng of amplified RNA was used to prepare cDNA libraries (Nextera XT DNA library preparation kit; Illumina). cDNA libraries for 4 biological replicates for both control (THD’GAL4/+ ...
-
bioRxiv - Developmental Biology 2024Quote: ... TDE buffer 25 mL (Illumina)) ...
-
bioRxiv - Plant Biology 2021Quote: ... we sequenced a subset of 12 samples (six Salix and six Xanthium from both extraction methods) with the Illumina technology (Illumina Inc., San Diego, USA). Libraries were prepared using either the “NEBNext Ultra II DNA Library Prep Kit for Illumina®” (for old herbarium specimens ...
-
bioRxiv - Microbiology 2020Quote: ... Five DNA extractions were performed per soil sample and pooled for metagenomic library preparation with the TrueSeq DNA kit (Illumina Inc., San Diego, CA). Sequencing was performed on the Illumina HiSeq platform to generate 6.4 billion of paired-end reads of 150bp.
-
bioRxiv - Pathology 2024Quote: ... Samples were sent to LGC Genomics GmbH (Berlin, Germany) for DNA extraction and sequencing (150 bp paired-end reads on an Illumina NextSeq 500/550 platform). All DNA extraction ...
-
bioRxiv - Genomics 2021Quote: ... 3nM libraries were loaded across 4 lanes on the HiSeq 4000 (Illumina).
-
bioRxiv - Genomics 2023Quote: ... 4 out of 49 samples only had microarray genotype data from Illumina Omni2.5 chips ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The final library was diluted to 4 nM using Resuspension Buffer (Illumina). The rest of the library preparation was completed following the Denature and Dilute Libraries Guide for MiniSeq System by Illumina ...
-
bioRxiv - Molecular Biology 2023Quote: ... 2 or 4 nM concentration and run on NextSeq 550 sequencer (Illumina) with NextSeq 500/550 High Output v2.5 (75 cycles PE ...
-
bioRxiv - Genetics 2021Quote: ... Sequencing libraries for whole-genome sequencing were prepared from 200-300 ng of DNA using DNA Prep Kit (Illumina), with KAPA HiFi Uracil+ Kit (Roche ...
-
bioRxiv - Genomics 2020Quote: ... Hiseq3000 SBS&Cluster high-throughput NGS library preparation kit (Cat. No. FC-410-1002, Illumina, San Diego, CA, USA), (VAHTS Universal DNA Library Prep Kit (ND608-01 ...
-
bioRxiv - Genomics 2020Quote: The amplified fragments (2 ng) were processed using the Nextera XT DNA Library Prep kit and indexes adapters (Illumina) following the procedure recommended by the manufacturer ...
-
bioRxiv - Microbiology 2019Quote: ... Libraries that passed QC (>3 ng/μL) were sequenced using an Illumina HiSeq sequencer (Illumina, San Diego, CA, USA) with the paired-end 150-bp sequencing model based on >5G raw data output per sample.
-
bioRxiv - Genetics 2019Quote: ... We tagmented 5 ng of cDNA using 1 uL Nextera Tagment DNA Tn5 transposase (Illumina, San Diego, CA, 15027916) in a 10 uL tagmentation mix for 10 minutes at 55 °C.
-
bioRxiv - Genomics 2019Quote: ... We normalized the cDNA concentrations and used 0.075 ng of each in a quarter volume of a NexteraXT (Illumina) library construction reaction ...
-
bioRxiv - Molecular Biology 2019Quote: Strand-specific mRNA-seq libraries were prepared from 500–4000 ng total RNA using the TruSeq Stranded mRNA (Illumina) or SENSE mRNA-Seq (Lexogen ...
-
bioRxiv - Cancer Biology 2019Quote: Total RNA was diluted to 50 ng/µl and prepared using the TruSeq Stranded mRNA Library Preparation Kit (Illumina). Samples were sequenced on a NextSeq 500 instrument with NextSeq 500/550 High Output v2.5 kits (Illumina ...
-
bioRxiv - Molecular Biology 2021Quote: ... RNA sequencing was performed by BGI (Hong Kong) using 1000 ng RNA for the TruSeq cDNA library construction (Illumina). 3Gb data was generated per sample on a HiSeq 2000 sequencer (Illumina ...
-
bioRxiv - Genomics 2019Quote: ... and aliquots of 270–500 ng were made into cDNA libraries using the TruSeq mRNA-Seq library kit (Illumina).
-
bioRxiv - Cell Biology 2022Quote: ... 600 ng RNA was used for library preparation using the NEBNext Ultra8482 II Directional RNA Library Prep Kit (Illumina) and the QIAseq FastSelect RNA Removal Kit (Qiagen) ...
-
bioRxiv - Cell Biology 2019Quote: ... cDNA libraries were prepared using 500 ng of total RNA using the TruSeq RNA Sample Preparation Kit v2 (Illumina) with the added benefit of molecular indexing ...
-
bioRxiv - Cancer Biology 2019Quote: ... The sequencing libraries were constructed from 500 ng of total RNA using the Illumina’s TruSeq RNA Sample pre kit V2 (Illumina) following the manufacturer’s instructions ...
-
bioRxiv - Genetics 2019Quote: ... 10 ng of ChIP DNA was used to construct ChIP-Seq libraries using TruSeq ChIP Library Preparation Kit (Illumina). Reads from the Myf6 ChTAP- and the EV-ChTAP-Seq were mapped to the mouse mm10/GRCm38 mouse genome assembly ...
-
bioRxiv - Cancer Biology 2021Quote: ... Sequencing libraries were prepared from total RNA (500 ng) using the TruSeq Stranded mRNA Library Preparation kit (Illumina, Inc.) and uniquely barcoded adapters (RNA LT adapters ...
-
bioRxiv - Microbiology 2021Quote: ... The Illumina NGS libraries were prepared using the Nextera DNA Flex Library Prep following the manufacturer’s instructions (Illumina Inc.). High-throughput sequencing was performed with a MiSeq Illumina sequencer (2 × 300 bp ...
-
bioRxiv - Developmental Biology 2021Quote: ... Dual indexed sequencing libraries were made out of 5 ng cDNA from the above preparations using Illumina Nextera library preparation kit according to manufacturer’s instructions (Illumina). Quality checked and equimolar pooled libraries were sequenced in a HiSeq 4000 Illumina system ...
-
bioRxiv - Genomics 2022Quote: ... RNA-seq libraries were prepared from 600 ng of total RNA (RNA integrity number (RIN) >8.0) with TruSeq Stranded Total RNA Human/Mouse/Rat kit (Illumina). For polysome immunoprecipitation experiments ...
-
bioRxiv - Plant Biology 2021Quote: Total RNA (500 ng per sample) was used to synthesize libraries using a TruSeq Stranded mRNA Kit v2 (Illumina). Cluster generation was performed at the Functional Genomics Center Zurich (FGCZ ...
-
bioRxiv - Cancer Biology 2021Quote: ... RNA-Seq libraries were prepared with 500 ng total RNA using the TruSeq stranded mRNA Sample Preparation Kit according to the manufacturer’s protocol (Illumina). RNA-seq libraries were multiplexed ...
-
bioRxiv - Neuroscience 2022Quote: ... 500 ng of RNA was used as input for library preparation using the Illumina TruSeq (Illumina, San Diego, US). Libraries were quality checked ...
-
bioRxiv - Physiology 2022Quote: ... RNA-seq libraries were prepared from 500 ng of total RNA with the Illumina TruSeq Stranded mRNA reagents (Illumina) using a unique dual indexing strategy ...
-
bioRxiv - Microbiology 2022Quote: ... Extracted DNA was adjusted to a concentration of 0.2 ng/μL and treated using the Nextera XT DNA library preparation kit (Illumina) to produce fragments of approximately 500 bp ...
-
bioRxiv - Plant Biology 2022Quote: ... At least 2 ng of ChIP-DNA were used for Illumina library preparation according to the manufacturer’s instructions (Illumina). Library construction and sequencing (150 bp of paired-end sequences ...