Labshake search
Citations for Bangs Laboratories :
51 - 100 of 247 citations for Streptavidin magnetic beads since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: ... 10 ul of ConA-coated magnetic beads per sample (Bangs Laboratories BP531) were activated by washing twice with Binding Buffer (20mM HEPES pH7.5 ...
-
bioRxiv - Biophysics 2020Quote: We prepared two stock solutions: ‘tracer beads’ with d = 0.989 μm streptavidin coated Flash Red fluorescent beads (Bangs Laboratories) and ‘tether beads’ with 4.95 μm streptavidin coated polymer particles (Bangs Laboratories ...
-
bioRxiv - Biophysics 2020Quote: ... Streptavidin-coated micro-beads (diameter of 3 µm) were purchased from Bangs Laboratories Inc ...
-
bioRxiv - Immunology 2023Quote: ... Then fluorescent (APC) streptavidin microsphere beads (63µl from stock) (1 µm, Bangs Laboratories) were conjugated with the biotinylated Spike protein (25 µg ...
-
bioRxiv - Genomics 2021Quote: ... For the cells to bind to Concanavalin A-coated magnetic beads (Bangs Laboratories), 10 µL activated beads were added into each sample and the cell-bead mixture was rotated at RT for 10 min ...
-
bioRxiv - Molecular Biology 2024Quote: ... 500,000 cells were immobilized to activated Concanavalin A-coated magnetic beads (Bangs Laboratories) followed by permeabilization with wash buffer containing Digitonin (Promega) ...
-
bioRxiv - Immunology 2024Quote: ... Cells were then washed and bound to magnetic Con A beads (Bangs Laboratories) in 200uL PCR strip tubes ...
-
bioRxiv - Developmental Biology 2024Quote: ... cells were bound to BioMag Plus Concavalin A magnetic beads (Bangs Laboratories, BP531) and incubated with rabbit anti H3K27AC (AbCam ...
-
bioRxiv - Neuroscience 2024Quote: ... bound to wheat germ agglutinin (WGA) coated magnetic beads (Bangs Laboratories, Fishers, IN), and incubated for overnight at 4 °C with a primary antibody in Antibody Binding Buffer (20 mM HEPES pH 7.5 ...
-
bioRxiv - Cancer Biology 2023Quote: ... cells were harvested and bound to concanavalin A-coated magnetic beads (Bangs Laboratories, BP531) after a 10 min incubation at room temperature on a rotator ...
-
bioRxiv - Biochemistry 2024Quote: ... a solution of ABBSA buffer containing streptavidin-coated polystyrene beads (1 μm diameter, Bangs Laboratories), filaments of 0.3 nM TMR-phalloidin-labelled biotinylated actin (Cytoskeleton ...
-
bioRxiv - Biophysics 2024Quote: C-terminally biotinylated HA was bound to streptavidin-coated beads of 200nm diameter (Bangs Laboratories) to mimic the viral surface ...
-
bioRxiv - Genomics 2023Quote: ... after washes the cells were incubated with concanavalin A coated magnetic beads (Bangs Laboratories #BP531) for 15 min at RT ...
-
bioRxiv - Systems Biology 2024Quote: ... frozen cells were thawed and immobilized onto concanavalin A-coated magnetic beads (Bangs Laboratories, BP531). The bead-bound cells were resuspended in antibody binding buffer with BSA (20mM HEPES at pH 7.5 ...
-
bioRxiv - Neuroscience 2021Quote: ... followed by addition of 10 µl pre-activated concanavalin A coated magnetic beads (Bangs Laboratories-BP531). Tubes were held on mixing platform at RT for 10 mins ...
-
bioRxiv - Cancer Biology 2021Quote: ... 5×105 cells were washed and bound to concanavalin A-coated magnetic beads (Bangs Laboratories, BP531). The cells were then permeabilized with Wash Buffer (20 mM HEPES pH 7.5 ...
-
bioRxiv - Neuroscience 2021Quote: ... 0.4% IGEPAL CA-630 was added to improve binding to concanavalin A magnetic beads (Bangs Laboratories BP531). CUT&RUN was performed on brain nuclei ...
-
bioRxiv - Immunology 2022Quote: ... re-suspended in 400μl (final) of wash buffer containing 20μl of BioMagplus Concanavalin A-coated magnetic beads (Bangs Laboratories) per reaction and rotated for 15min at 4°C to allow the cells to bind ...
-
bioRxiv - Cell Biology 2020Quote: ... the MatTek dish was placed on a Leica SP8 confocal microscope and ~10,000 streptavidin coated silica beads (2 μm, Bangs Laboratories) were added ...
-
bioRxiv - Cell Biology 2020Quote: ... J774.A1 cells expressing GFP-LC3A (human) were assayed with IgG coated magnetic beads (ProMag 3 Series-Amine, Bangs Laboratories). The magnetic beads were prepared according to the manufacture’s guidelines ...
-
bioRxiv - Microbiology 2022Quote: ... was incubated with a solution containing streptavidin-coated polystyrene beads containing the dye Flash red with 1 µm diameter (Bangs Laboratories). To ensure homogenous coverage with LecB-biotin ...
-
bioRxiv - Cancer Biology 2023Quote: ... 400,000 NC cells were mixed with 100,000 Kc167 cells then incubated for 5-10 minutes with 10 µl of Concanavalin A-coated magnetic beads (Bangs Laboratories #BP531) in Binding Buffer (20 mM HEPES-KOH pH 7.9 ...
-
bioRxiv - Cancer Biology 2022Quote: ... 5×105 NPCs grown either in alone or in coculture conditions were attached to concanavalin A–coated magnetic beads (Bangs Laboratories, BP531) and incubated overnight at 4°C in 0.05% Digitonin-Antibody buffer containing a rabbit anti mouse-p53 Ab (1:100 Leica ...
-
bioRxiv - Cancer Biology 2022Quote: ... 200,000 cells were harvested and washed twice and captured by the addition of 10□μl pre-activated concanavalin A coated magnetic beads (Bangs Laboratories-BP531). Cells were then resuspended in 100 μl cold Antibody Buffer and 1□0μl antibody (H3K4me3 ...
-
bioRxiv - Genomics 2023Quote: ... 0.2 x 106 cells were bound to 10 μL of Bio-Mag Plus Concanavalin A coated magnetic beads (Bangs laboratories, cat. No. BP531), equilibrated with binding buffer (20 mM K-HEPES pH7.9 ...
-
bioRxiv - Biophysics 2021Quote: ... 1 μm streptavidin coated polystyrene particles and 150 nm streptavidin coated gold nanoparticles were purchased from Bangs Laboratories and Nanopartz respectively ...
-
bioRxiv - Immunology 2021Quote: 0.2 μm streptavidin coated polystyrene microspheres (Bangs Laboratories) were incubated at 37°C for 1 h with biotinylated anti-IgM at a final concentration of 0.561 μg/109 microspheres and biotinylated OVA (Nanocs ...
-
bioRxiv - Biophysics 2023Quote: ... beads (60 μm diameter polystyrene beads; Bangs laboratories) were imaged on each day of experiments to find the intensity to conversion factor after comparison with IRM images of cells ...
-
Long-Range Electrostatic Interactions Significantly Modulate the Affinity of Dynein for MicrotubulesbioRxiv - Biophysics 2021Quote: ... streptavidin-coated polystyrene microspheres (CP01004, Bangs Laboratories, Inc., Fishers, IN) three times with centrifugation (11,000 × g ...
-
bioRxiv - Immunology 2021Quote: 0.2 μm Dragon Green streptavidin microspheres (Bangs Laboratories, 10 mg/ml) were incubated at 37°C for 1 h with biotinylated anti-IgM at a final concentration of 1.52 μg/109 microspheres ...
-
bioRxiv - Molecular Biology 2021Quote: BioMag Nuclease-Free Streptavidin particles (Bangs Laboratories, USA, Cat. No. BM568) were washed and equilibrated with the binding buffer (5 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2023Quote: ... and additionally had 1μm streptavidin-coated silica microspheres (Bangs Labs Inc.), and three separate [ATP] (1 ...
-
bioRxiv - Microbiology 2021Quote: ... red fluorescent beads (Bangs Laboratories) were coated with 5-Dodecanoylaminofluorescein Di-β-D-Galactopyranoside (C12FDG ...
-
bioRxiv - Immunology 2020Quote: ... Silica beads (SS06N, Bangs Lab), NHS-ester form of Alexa 488 and 647 dyes (Thermo fisher Scientific) ...
-
bioRxiv - Neuroscience 2020Quote: Fluorescent beads (FSEG004; Bangs Laboratories, Inc.) were immerged into water and mounted between a standard microscope slice and a thin (4 um ...
-
bioRxiv - Microbiology 2023Quote: ... Tracer beads (Bangs Laboratories, Fishers, IN) embedded in samples were tracked over the course of an 8 second video ...
-
bioRxiv - Physiology 2024Quote: ... 1 μm fluorescent beads (Bangs Laboratories) were added to the pre-polymer solution and polymerized into the gel’s bulk to enable visualization via fluorescence microscopy ...
-
bioRxiv - Genomics 2024Quote: ... Concanavalin A beads (Bangs Laboratories, BP531) were activated by resuspending into 10 volumes of Bead Binding Buffer (20 mM HEPES pH 7.5 ...
-
bioRxiv - Bioengineering 2024Quote: ... and PS-CNP beads (Bangs Laboratories) were purchased ...
-
bioRxiv - Neuroscience 2024Quote: ... One to 1.5 microliters of 5.8 µm diameter magnetic microbeads (Bangs Laboratories, Fishers, IN) were injected into the anterior chamber of both eyes using a manual micromanipulator (WPI ...
-
bioRxiv - Bioengineering 2021Quote: Polystyrene microspheres coated with Streptavidin (mean diameter 4.95 µm) were purchased from Bangs Laboratories (US). Washes and incubations were preferably performed in low-binding tubes (Eppendorf ...
-
bioRxiv - Cell Biology 2021Quote: ... a 5% w/v suspension of 3.0 µm beads or 0.5% w/v suspension of 2.0 µm Dragon Green fluorescent beads (Bangs Laboratories) was incubated with 0.5 mg/mL DQ-Red BSA (ThermoFisher Scientific ...
-
bioRxiv - Immunology 2022Quote: Multivalent MOG-bead antigens were generated using non-functionalized 1 μm diameter silica beads (Bangs Laboratories, Inc. (SS04000) using the manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2020Quote: ... Activated Concanavalin-A beads (Bangs Laboratories BP531) in binding buffer (20 mM HEPES pH 7.5 ...
-
bioRxiv - Biophysics 2020Quote: Streptavadin-coated beads (Bangs Laboratories, Inc; CP01004) were freshly washed each day by centrifuging for 1 minute at 5000 x g and then resuspending in 20 mM HEPES pH 6.8 ...
-
bioRxiv - Microbiology 2022Quote: ... 5 μm carboxylated silica beads (Bangs Labs) were washed in Mes buffer (Sigma M1317 ...
-
bioRxiv - Bioengineering 2022Quote: The Bangs beads (Bangs Laboratories, Cat: 815A) were collected and resuspended in PBS ...
-
bioRxiv - Immunology 2023Quote: ... Silica beads were purchased from Bangs Laboratories, Inc ...
-
bioRxiv - Genetics 2022Quote: ... 10 μl Concanavalin A beads (Bangs Laboratories) were equilibrated with 100 μl binding buffer (20 mM HEPES-KOH ...
-
bioRxiv - Synthetic Biology 2022Quote: ... 1×107 5μm silica beads (Bangs Laboratories) were vortexed thoroughly and washed three times with PBS using 1500xg and 30 seconds centrifugation steps ...