bioRxiv - Molecular Biology 2021Quote: ... and lysozyme were determined with a Real Time Thermal cycler qTower (Analytical Jena) system using a SensiFast SYBR kit (Bioline) according to the supplier’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... real-time PCR cycler with SensiFAST SYBR master mix (Bioline BIO-98050) using primers for target genes and 18S rRNA or phosphoglycerate kinase (PGK ...
-
bioRxiv - Molecular Biology 2024Quote: ... real-time PCR was conducted using the SensiFAST SYBR real-time PCR kit (Bioline). The obtained data were normalized to the human endogenous control (GAPDH ...
-
bioRxiv - Neuroscience 2022Quote: ... was performed on a Qiagen Rotor-Gene Q 2plex real-time PCR cycler with 2x SensiFAST™ SYBR No-ROX mix (Bioline, #98020). Phosphoglycerate kinase 1 (Pgk1 ...
-
bioRxiv - Neuroscience 2020Quote: ... Quantitative PCR was performed using C1000 Touch Thermal Cycler (BioRed) and SYBR mix (Bioline, GmbH, Germany), using validated primer sets (Herber et al ...
-
bioRxiv - Plant Biology 2023Quote: ... Real-time PCR was performed using SYBR green supermix (Bioline) as per the manufacturer’s instructions on a CFX384 Touch real-time PCR detection system ...
-
bioRxiv - Immunology 2021Quote: ... Real-time RT-PCR using SensiFast SYBR No-Rox kit (Bioline) was performed to determine gene expression ...
-
bioRxiv - Microbiology 2021Quote: ... Real-time PCR was performed using SensiFAST SYBR & Fluorescein Kit (Bioline) as previously described (25,32) ...
-
bioRxiv - Immunology 2022Quote: ... and used to perform a SYBR-based real-time PCR (BioLine) with primers (Table 1 ...
-
bioRxiv - Developmental Biology 2022Quote: ... For real-time PCR SYBR Green Master mix (Bioline BIO-94020) was used ...
-
bioRxiv - Developmental Biology 2023Quote: ... For real-time PCR SYBR Green Master mix (Bioline BIO-94020) was used ...
-
bioRxiv - Molecular Biology 2021Quote: ... Real-time PCR analysis was carried out using SYBR Green mix (Bioline) in a Bio-Rad CFX-100 RT-qPCR ...
-
bioRxiv - Neuroscience 2022Quote: ... Real-time quantitative PCR (RT-qPCR) reactions were performed (Bioline #BIO-98020). NCBI primer BLAST software was used for oligonucleotide design (Ye et al. ...
-
bioRxiv - Microbiology 2021Quote: ... and quantitative real-time-PCR (qRT-PCR) reactions were performed in triplicate (Bioline) and monitored by a Roche Lightcycler 96 ...
-
bioRxiv - Cancer Biology 2019Quote: ... in a HT7900 Real Time PCR System using SensiMix SYBR-Green Mix (Bioline) with standard cycling conditions ...
-
bioRxiv - Plant Biology 2021Quote: ... Real-time PCR was performed with the SensiFastTM SYBR No-Rox Kit (Bioline) in a Roche Light Cycler 480 as described by the manufacturer ...
-
bioRxiv - Microbiology 2021Quote: ... and real-time qPCR was performed using SensiFast SYBR Lo-ROX kit (Bioline). RT-qPCR was carried using primer sets for the three reporter genes and three housekeeping genes (actin I (p100 ...
-
bioRxiv - Developmental Biology 2019Quote: Quantitative Real-time PCR was performed with Sensimix SYBR Green no-ROX (Bioline) on a Corbett Rotor-Gene 6000 (Corbett) ...
-
bioRxiv - Plant Biology 2021Quote: ... Real-time quantitative PCR was performed using the Sensimix SYBR low-rox kit (Bioline) and the primers in Supplementary Table 2 ...
-
Isonicotinamide extends yeast chronological lifespan through a mechanism that diminishes nucleotidesbioRxiv - Biochemistry 2021Quote: ... and quantitated by real-time PCR reactions using SensiMix SYBR Hi-ROX Mastermix (Bioline) run on a StepOne Plus thermocycler (Applied Biosystems) ...
-
bioRxiv - Microbiology 2021Quote: ... Real-time PCR was carried out using the SensiFAST SYBR Hi-ROX kit (Bioline, BIO92005). Briefly ...
-
bioRxiv - Physiology 2019Quote: ... Quantitative real-time PCR were carried out using SensiFAST™ SYBR No-ROX (2X, Bioline) on a LightCycler 480 System (Roche Diagnostics ...
-
bioRxiv - Cell Biology 2023Quote: ... Real-time PCR was performed using the SensiFAST SYBR Lo-ROX Kit (BIO-94020, Bioline). Primers are shown in Supplementary Table 1 ...
-
CRISPR-SID: identifying EZH2 as a druggable target for desmoid tumors via in vivo dependency mappingbioRxiv - Cancer Biology 2021Quote: ... Real-time quantitative PCR was performed using the SensiFAST™ SYBR® No-ROX Kit (Bioline) combined with a LightCycler® 480 Real-Time PCR System (Roche) ...
-
bioRxiv - Neuroscience 2022Quote: Target gene real-time qPCR analyses were conducted using SYBR Green Master Mix (Bioline #BIO-98005) with the LightCycler® 480 System (Roche ...
-
bioRxiv - Pathology 2023Quote: ... All real-time PCR reactions were performed in 20 μL volumes containing 10 μL Immomix (Bioline) and 5 μL of DNA template ...
-
bioRxiv - Cell Biology 2024Quote: ... Real time qPCR was performed using a RotorGene 6000 (Corbett Research) instrument with SYBR (Bioline, UK) and results were analysed using beta-actin (Actb ...
-
bioRxiv - Plant Biology 2020Quote: ... Quantitative Real-Time PCR was performed using a SensiFAST™ SYBR® No-ROX Kit (Bioline; www.bioline.com). Fluorescence was monitored with a CFX384 thermal cycler (Bio-Rad) ...
-
bioRxiv - Microbiology 2020Quote: ... Real-time RT PCR was performed using the SensiFAST™ Probe Lo-ROX one-step kit (Bioline). In each reaction the primers final concentration was 600nM and the probe concentration was 300nM ...
-
bioRxiv - Microbiology 2020Quote: ... Real-time RT-PCR was conducted with SensiFAST™ Probe Lo-ROX One-Step Kit (Bioline, 78005) and analyzed with the 7500 Real Time PCR System (Applied Biosystems) ...
-
bioRxiv - Plant Biology 2023Quote: ... and real time PCR reactions were completed in duplicate for each sample using a SensiMix SYBR (Bioline); 95◻ for 10 min ...
-
bioRxiv - Molecular Biology 2022Quote: ... Real- time PCR was performed using 2x SensiMix SYBR and Fluorescein Kit (Bioline, QT615-05, Luckenwalde, Germany), 20ng cDNA and pre-tested gene-specific primer sets (listed in Supplementary table 3) ...
-
bioRxiv - Molecular Biology 2019Quote: ... Real-time PCRs were analyzed by SensiFAST™ SYBR® Hi-ROX Kit (BIO-92020, Bioline, London, UK). A PCR program was used as described ...
-
bioRxiv - Immunology 2021Quote: ... Real time quantitative PCR (RT-qPCR) analysis was carried out using the SensiMix SYBR No-Rox kit (Bioline), using primers and conditions shown in Supplemental Table 1 ...
-
bioRxiv - Cell Biology 2022Quote: ... Real-time PCR analysis was performed according to the manufacturer’s protocol (SensiMix™ SYBR® & Fluorescein Kit, Bioline) with a MyiQ Single-Color Real-Time PCR detection system (Bio-Rad ...
-
bioRxiv - Cell Biology 2023Quote: ... Quantitative real-time PCR reactions were performed with different sets of primers and Sensifast SYBR (Bioline, Taunton, MA) on a CFX96 or CFX384 Real-Time PCR Detection System (Bio-Rad ...
-
bioRxiv - Plant Biology 2020Quote: ... Real-time PCR reactions were performed in a 384-well microlitre using SensiFAST SYBR® No-ROX Kit (Bioline). The primers used here were designed using the open-source program QuantPrime-qPCR primer designed tool (Arvidsson et al. ...
-
bioRxiv - Cancer Biology 2021Quote: ... The relative amount of mRNA transcripts was measured by real-time PCR using SensiFAST SYBR N-ROX Kit (Bioline) and calculated by Bio-Rad CFX Manager Software ...
-
bioRxiv - Neuroscience 2023Quote: ... Real-time RT-PCR was performed using a SensiFastTM SYBR® Hi-ROX kit (#BIO-92020; Bioline USA Inc.) in an Applied Biosystems QuantStudio 7 Flex Real-Time PCR system (Thermo Fisher Scientific Inc.) ...
-
bioRxiv - Plant Biology 2023Quote: ... Real-time RT-PCR was performed on 1:10 diluted cDNA using the SensiFAST SYBR No-ROX Kit (Bioline). Three biological and technical replicates were analyzed per genotype ...
-
bioRxiv - Cell Biology 2020Quote: ... The relative amount of PAK transcript variants was measured by quantitative real-time PCR (qPCR) using SensiFAST SYBR No-ROX Kit (Bioline) and calculated using Bio-Rad CFX Manager Software ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Telomere length was measured using real-time quantitative PCR (qPCR) and a SensiMix SYBR No-ROX Kit (Bioline, Sydney, Australia). The telomere primers used were Tel1b (5’-CGGTTTGTTTGGGTTTGGGTTT GGGTTTGGGTTTGGGTT-3’ ...
-
bioRxiv - Microbiology 2019Quote: ... Reverse transcription and quantitative real-time PCRs (qRT-PCR) were performed using the SensiFast SYBR No-ROX One Step kit (Bioline) in a Rotor-Gene Q Lightcycler (Qiagen) ...
-
bioRxiv - Plant Biology 2020Quote: ... Quantitative real-time PCR reactions using cDNA samples as template were carried out using a SensiFAST SYBR No-ROX Kit (Bioline) in a CFX96 Touch (BIO-RAD ...
-
bioRxiv - Microbiology 2021Quote: ... Quantitative PCR was done using 10 ng (broth culture) or 100 ng (fecal samples) of genomic DNA as template with SYBR Green Real-Time qPCR reagents (Bioline), primers at a final concentration of 1 μM ...
-
bioRxiv - Microbiology 2020Quote: ... Real-time PCR reactions were performed in 12 μL mixtures containing 1 x SensiFAST SYBR No-ROX mix (Bioline, Australia), 400 nM of each forward and reverse primer (Table 3 ...
-
bioRxiv - Biochemistry 2022Quote: ... First-strand cDNA synthesis and subsequent real-time PCR was performed using SensiFast ™ SYBR No-Rox One-Step Kit (Cat.No. BIO- 72005 (Bioline)) ...
-
bioRxiv - Cell Biology 2022Quote: ... The resulting cDNA was subjected to real-time PCR in a Rotorgene 6000 (Corbett Life Science, New South Wales, Australia) using Immomix (2× dilution; Bioline), SYBR Green I (10,000× dilution ...
-
bioRxiv - Microbiology 2022Quote: ... IS2404 real-time PCR mixtures contained of 10.0□μl of 2x SensiFast Probe NO-ROX mix (BioLine Cat# BIO-86005), 3.2□μl of nuclease-free water ...
-
bioRxiv - Microbiology 2023Quote: ... Reverse transcription and quantitative real-time PCRs (qRT-PCR) were performed using the SensiFast SYBR No-ROX One Step kit (Bioline) in a Rotor-Gene Q lightcycler (Qiagen) ...