Labshake search
Citations for GE Life Sciences :
51 - 100 of 2278 citations for Neutrophil cytosol factor 1 NCF1 Human His since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: ... His-tag was cleaved by thrombin (GE Healthcare) and NaCl concentration was reduced to 100 mM ...
-
bioRxiv - Biochemistry 2023Quote: ... and purified using His-Trap HP (GE Healthcare) followed by gel filtration using HiLoad 16/60 Superdex 75 columns on an ÄKTA Xpress ...
-
bioRxiv - Biophysics 2024Quote: ... loaded onto a His-Trap column (GE Healthcare), and eluted by applying a linear imidazole gradient from 20 mM to 200 mM over 30 column volumes ...
-
bioRxiv - Plant Biology 2024Quote: ... purified on a His-Trap column (GE Healthcare) following the manufacturers’ instructions ...
-
bioRxiv - Biochemistry 2019Quote: ... fractions containing PGDH-His or RBBP9-His were concentrated and loaded onto a gel filtration column (Superdex 200, 10/300 GL, GE Healthcare) pre-equilibrated with 20mM sodium dihydrogen phosphate pH 7.4 ...
-
bioRxiv - Molecular Biology 2022Quote: ... NaCl concentration was readjusted to 500 mM by spiking with 5M NaCl stock solution and protein solution was dialyzed overnight into SEC1 buffer at 4°C followed by protein separation from His tag on a His-Trap column (GE Healthcare), concentration with an Amicon Ultra 15 MWCO10kDa (Millipore ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: SARS-CoV-2 PLpro-His (PLpro-His) protein was concentrated and loaded to a HiLoad 16/60 Superdex 75 size exclusion column (GE Healthcare) pre-equilibriated with 20 mM Tris pH 8.0 and 5 mM NaCl ...
-
bioRxiv - Molecular Biology 2019Quote: ... Both the cleaved His-tag and the His-tagged protease were removed from protein solutions by passage over loose nickel beads (GE Healthcare). The tag-free NDC-NDC was further purified with HiTrap SP HP ion exchange column (GE Healthcare ...
-
bioRxiv - Biochemistry 2022Quote: ... soluble His-GST-APLFAD (or His-SUMO-APLFAD) was loaded on a 5 mL HisTrap FF column (GE Healthcare Life Sciences), pre-equilibrated in lysis buffer (50 mM Tris ...
-
bioRxiv - Biochemistry 2023Quote: ... the His-MBP and His tags were removed by TEV protease and a passage through a Ni2+chelating Sepharose (GE Healthcare). The final purification step was size-exclusion chromatography on Superdex 200 size exclusion chromatography (GE Healthcare).
-
bioRxiv - Microbiology 2023Quote: His-SUMO-SEAL and His-SUMO-SEALGGG were analyzed by size-exclusion chromatography (SEC) on a Superdex S75 column (GE Healthcare) in buffer containing 20 mM of HEPES-NaOH ...
-
bioRxiv - Cell Biology 2019Quote: ... His-TWF-1 was further purified with Superdex-75 increase 10/300 GL gel filtration column (GE Healthcare) equilibrated 20 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2019Quote: ... The supernatant corresponding to His-JMJD6 (1-343) was loaded to 7mL of Ni-NTA resin (GE Healthcare), washed with nickel-binding buffer containing 20mM imidazole ...
-
bioRxiv - Biochemistry 2019Quote: ... Enzymes were purified from the cell lysate using a 1 ml His-Trap FF crude column (GE Healthcare) using an elution gradient from 10 to 250 mM imidazole in 25 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Microbiology 2021Quote: ... The lysate supernatant was than loaded on a Ni-NTA column (GE Healthcare, His Trap FF 1 ml) pre-equilibrated with a binding buffer (8 M Urea ...
-
bioRxiv - Microbiology 2020Quote: ... MS3_01370 was purified by IMAC by loading onto a prepacked 1 ml His-Trap HP column (GE Healthcare) equilibrated with lysis buffer at a flow rate of 1 ml/min using an AKTA-pure-25 FPLC (GE Healthcare) ...
-
bioRxiv - Biochemistry 2023Quote: ... Filtered lysate was applied to a 1-ml His-Trap (all FPLC columns were obtained from GE Healthcare) column using an ÄKTA FPLC ...
-
bioRxiv - Microbiology 2022Quote: ... Neutrophils were purified from the remaining cells by overlaying on a Ficoll density gradient (GE Healthcare, Chicago, IL) following centrifugation in Ficoll-Paque Centrifugation Media (GE Healthcare ...
-
bioRxiv - Biochemistry 2019Quote: ... adjusted to 0.15 M NaCl and 1 % (v/v) Triton X-100 and were applied to a 1 mL Hi-Trap heparin column (GE Healthcare Life Sciences) equilibrated with a modified phosphate-buffered saline (PBS) ...
-
bioRxiv - Genetics 2019Quote: ... The final antisera were purified separately using His-DBN-1(1-132) bound to NHS-activated Sepharose High Performance (GE Healthcare Life Science). Both purified antibodies were tested in western blot ...
-
bioRxiv - Molecular Biology 2021Quote: ... loaded onto 5 ml His-FFTrap column (GE Healthcare), equilibrated in His-A buffer (50 mM HEPES/NaOH pH 8.5 ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... and ion-exchange (Hi-Load Q column, GE Healthcare) for the 5FW-labeled protein ...
-
bioRxiv - Microbiology 2020Quote: ... were transferred onto a His SpinTrap column (GE Healthcare). The purified fractions were subjected to desalting and concentration using an Amicon Ultra centrifugal filter unit (30 kDa cutoff ...
-
bioRxiv - Molecular Biology 2019Quote: ... or Ni-NTA-Agarose (GE healthcare, His-B-MYB). Lysates of HeLa cells expressing HA-tagged B-MYB constructs were incubated with 5 mg immobilized GST or GST-WW1/2-YAP for 3 hours at 4°C ...
-
bioRxiv - Immunology 2021Quote: ... functionalised with an anti-His capture kit (GE Healthcare) using a Biacore T200 instrument ...
-
bioRxiv - Microbiology 2020Quote: ... The six-His-tagged BclA3CTD protein was purified under native conditions using the His-Trap column as recommended by the manufacturer (GE Healthcare Life Science). The purified protein was desalted and concentrated with the Centricon cutoff 10 kDa (Merck Millipore) ...
-
bioRxiv - Plant Biology 2022Quote: ... and the mixture of MoCel10A-His and OsCBMIP-His preincubated at 4 °C for 30 min were applied on Superdex G-75 column (GE Healthcare, Buckinghamshire, UK) equilibrated with sodium phosphate buffer (50 mM ...
-
bioRxiv - Microbiology 2021Quote: ... Binding of His-tagged Cg1978-C-His to GyrA-N-Strep was analyzed by SPR analysis in a Biacore 3000 device (GE Healthcare, Freiburg, Germany) using a Sensor Chip CM5 (GE Healthcare ...
-
bioRxiv - Cell Biology 2019Quote: ... The supernatant was loaded at 1 ml/min on a His-Trap FF-crude 5 mL column (GE Healthcare) equilibrated with PBS buffer ...
-
bioRxiv - Microbiology 2021Quote: ... and the resulting soluble fraction was applied on a Ni-NTA column (GE Healthcare, His Trap FF 1 ml) and purified according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... The His-tagged GlpQ protein was purified by Ni2+-affinity chromatography using a 1 ml HisTrap column (GE Healthcare) followed by size exclusion chromatography on a HiLoad 16/60 Superdex 200 pg column (GE Healthcare ...
-
bioRxiv - Molecular Biology 2024Quote: ... The soluble extract was loaded onto the Hi-Trap Chelating HP 1 ml pre-packed column (GE Healthcare/Cytiva) pre-equilibrated with buffer A containing 500 mM NaCl ...
-
bioRxiv - Microbiology 2021Quote: ... Purified 6x-His-SUMO or 6x-His-SUMO-Pat1 were coupled to NHS-activated Sepharose 4 fast flow resin (GE Healthcare, 17-0906-01) in ligand coupling buffer (200 mM NaHCO3 ...
-
bioRxiv - Molecular Biology 2020Quote: ... coli strain BL21 and purified using His-trap (GE Healthcare), Hi-Trap Q (GE Healthcare) ...
-
bioRxiv - Molecular Biology 2022Quote: ... was purified and washed on His-Trap columns (GE Healthcare) with buffer Ac (50 mM Tris pH 7.9 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Recombinant proteins were purified using a HIS-Trap (GE Healthcare) or Amylose resin (New England Biosciences ...
-
bioRxiv - Biophysics 2022Quote: ... and purified over a His-Trap HP column (GE Healthcare). The proteins were gel-filtered and their size was confirmed via a Superdex 200 column on an AKTA Pure system (GE Healthcare).
-
bioRxiv - Biochemistry 2021Quote: ... A His-Trap crude FF column (GE Healthcare Life Sciences) was used for this purification ...
-
bioRxiv - Microbiology 2021Quote: ... the obtained supernatants were filtered through sterile PVDF filters (pore size 0.22 μm) and loaded on 1 ml His-Trap columns (GE Healthcare), pre-equilibrated with ten column volumes of each Millipore water and sodium phosphate buffer A ...
-
bioRxiv - Biophysics 2021Quote: ... the myosin was purified by His-tag affinity purification with a 1 ml HisTrap HP nickel-sepharose column (GE Healthcare). The eluted myosin solution was then dialyzed overnight at 4 °C in a low-salt buffer (25 mM imidazole pH 7.0 ...
-
bioRxiv - Microbiology 2020Quote: ... Clarified cell lysates (following 40 min centrifugation at 11,000 x g and 0.2 μm filtration) were loaded onto prepacked columns (1 ml) of Ni-Sepharose media (His trap, GE Healthcare) using a benchtop peristaltic pump ...
-
bioRxiv - Immunology 2020Quote: ... Neutrophils (polymorphonuclear cells, PMNs) and peripheral blood mononuclear cells (PBMCs) were isolated by ficoll paque discontinuous gradient separation (GE Healthcare). PMNs were purified from the erythrocyte pellet by 5% dextran sedimentation ...
-
bioRxiv - Immunology 2022Quote: ... Neutrophils were isolated and purified by Percoll density gradient (72%, 63%, 54%, and 45%) (GE Healthcare; Cat. 17-5445-01). Isolated neutrophils were resuspended in RPMI 1640 (Corning ...
-
bioRxiv - Microbiology 2022Quote: Neutrophils were purified by centrifugation for 30 min at 1,300xg on a discontinuous Percoll gradient (GE Healthcare #17-0891-01) consisting of 62% (v/v ...
-
bioRxiv - Biophysics 2021Quote: ... The protein samples without a His tag were purified by an anion-exchange chromatography (HiTrapQ HP 1 mL column, GE healthcare) followed by gel filtration chromatography (Superdex 75 10/300 GL column ...
-
bioRxiv - Biophysics 2021Quote: ... The purification was done by purifying these two supernatants with 1 M NaCl containing Tris buffer using Hi-Trap Q-FF anion exchange column of ÄKTA Pure (GE healthcare). To maintain the oxidation activity of DsbA 0.3% H2O2 was added to the purified protein for overnight ...
-
bioRxiv - Molecular Biology 2020Quote: ... the buffer was supplemented with 30 mM imidazole and an additional 100 mM NaCl and passed through a 1 ml Hi-Trap Chelating column (GE Healthcare) to capture the N-terminal fragment that was cleaved by the TEV protease ...
-
bioRxiv - Microbiology 2020Quote: ... Purification of the protein from the soluble fraction was done in Binding buffer on a 1 mL His Trap Column (GE Healthcare) according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2020Quote: ... Solubilized IBs were purified by immobilized metal affinity chromatography (IMAC) by loading onto a prepacked 1 ml His-Trap HP column (GE Healthcare) equilibrated with lysis buffer containing 8M urea at a flow rate of 1 ml/min using an AKTA-pure-25 FPLC (GE Healthcare) ...
-
bioRxiv - Microbiology 2022Quote: The solution containing the proteins was loaded on a prepacked 1 ml or 5 ml His Trap HP Nickel column (GE Healthcare), which had been washed with 5 column volumes of water and equilibrated with 5 column volumes of buffer A (20 mM sodium phosphate ...