Labshake search
Citations for GE Life Sciences :
401 - 450 of 4014 citations for Monobenzyl Phthalate 100 Ug Ml In Mtbe Ring 1 2 13C2 Dicarboxyl 13C2 99% since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Bioengineering 2020Quote: A solution of 25 mg/L SC-SWCNTs and 2 mg/mL C16-PEG2k-ceramide in 1% sodium cholate was added to a 1 kDa molecular weight cutoff dialysis cartridge (GE Healthcare). The solution was dialyzed against water with multiple water exchanges for a week ...
-
bioRxiv - Biophysics 2022Quote: ... 3 volumes of 1 mg/mL affinity-purified antibody was gently rotated with 1 volume Protein A Sepharose beads (GE Healthcare) overnight at 4°C or 1 hour at room temperature ...
-
bioRxiv - Molecular Biology 2024Quote: ... 1:3 and 3:1 (w/w) at a concentration of 1 mg/mL were separated on a Superdex 200 10/30 column (GE Healthcare) using a LC1100 HPLC System (Agilent Technologies ...
-
bioRxiv - Biochemistry 2022Quote: ... 100 µL TIR-SAVED (10.9 mg.mL-1) were injected into the Superose 12 column 10/300 GL (GE Healthcare) in 20 mM Tris-HCl ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... 1 mM DTT) and purified by size-exclusion chromatography in a HiLoad 26/100 Superdex 200 column (GE Healthcare) pre-equilibrated with gel filtration buffer ...
-
bioRxiv - Microbiology 2021Quote: ... The MxiN and Spa33 were combined with an excess of MxiN and the mixture was concentrated to a final volume of 2 mL for injection onto a Hi Load 26/600 Superdex 200 pg column (GE Healthcare Life Sciences). The protein absorbance at 280 nm was monitored to detect protein elution on an AKTA system (GE Healthcare Life Sciences) ...
-
bioRxiv - Genomics 2021Quote: ... DNA was stained with 0.2 µg/ml ethidium bromide (EtBr) (Nacalai Tesque, 14631-94) and detected using a Typhoon FLA9000 gel imaging scanner (GE Healthcare, Chicago, Illinois). Gel images were processed using ImageJ 1.8.0 (NIH ...
-
bioRxiv - Cell Biology 2021Quote: ... 0.1 mM ATP) overnight at 4°C and loaded onto a 2-ml Glutathione-Sepharose 4B (GE Healthcare Life Sciences, Piscataway, NJ, USA) column pre-charged with GST-N-WASp-VCA (Nolen & Pollard ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was concentrated to 2-3 mL for separation on exclusion size chromatography (HiLoad 16/600 SuperdexTM 75pg, GE Healthcare; ÄKTA Avant). Finally ...
-
bioRxiv - Biophysics 2023Quote: ... size exclu-sion chromatography was conducted by injecting 2-5 mL sample onto HiLoad 16/600 Superdex 200 Column (GE Healthcare Life Sciences) connected to a BioRad NGC Quest 10 FPLC system ...
-
bioRxiv - Immunology 2021Quote: ... the mAb was purified using a 1 mL HiTrap Protein A HP column (GE Healthcare). The media was diluted with an equal volume of Protein A IgG Binding Buffer (Thermo Scientific ...
-
bioRxiv - Systems Biology 2022Quote: ... The filtered lysate was loaded onto a 1 ml HisTrap FF (GE Healthcare, Freiburg, Germany) and unbound protein was removed with 20 column volumes of 15% buffer B (50 mM HEPES/KOH pH 7.8 ...
-
bioRxiv - Biochemistry 2020Quote: ... 1 mM benzamidine) and loaded on a 5 ml HiTrap IMAC HP column (GE Healthcare). After a wash step for 3 column volumes in 30% IMAC buffer B (same as IMAC A but 500 mM imidazole) ...
-
bioRxiv - Biophysics 2022Quote: ... to ~ 1 mL and further purified on a Superdex 200 10/300 Increase (GE Healthcare) column equilibrated with buffer containing 20 mM Tris-HCl (pH 7.5) ...
-
bioRxiv - Molecular Biology 2020Quote: ... The supernatant was then loaded on a 1 mL HisTrap FF Crude column (GE Healthcare) with flow rate of 1 mL/min using the AKTA FPLC ...
-
bioRxiv - Microbiology 2021Quote: ... and the supernatant (crude extract) loaded on a 1-ml His-Trap column (GE Healthcare) previously equilibrated with Buffer H ...
-
bioRxiv - Neuroscience 2020Quote: ... The supernatant was loaded onto a 1 ml HiTRAP DEAE column (GE Healthcare, Boston, MA) for ion exchange chromatography using an GE Akta Purifier (buffer A ...
-
bioRxiv - Biochemistry 2019Quote: ... The clarified extract was applied to a 1 mL HisTrap HP column (GE Life Sciences) on an AKTA FPLC (Amersham Pharmacia) ...
-
bioRxiv - Microbiology 2020Quote: ... using multiple runs over a 1 ml Protein-A HiTrap column (GE Healthcare Life Sciences) on an ÄKTA FPLC (GE Healthcare Life Sciences) ...
-
bioRxiv - Immunology 2020Quote: ... at a flow rate of 1 ml/min using an EttanLC HPLC system (GE Healthcare) with buffer A (0.1 % trifluoroacetic acid (TFA) ...
-
bioRxiv - Microbiology 2022Quote: ... to be separated with two in-parallel 1-mL HisTrap FF crude columns (GE Healthcare). The column was washed with lysis buffer supplemented with 10 mM imidazole ...
-
bioRxiv - Molecular Biology 2023Quote: ... The dialyzed samples were subsequently loaded onto a 1 mL StrepTrap HP column (GE Healthcare), which was washed with 20 CV of binding buffer ...
-
bioRxiv - Microbiology 2022Quote: ... and loaded onto an ion exchange column (HiTrap™ Q HP 1 mL, GE Healthcare) equilibrated with 0.05% LDAO ...
-
bioRxiv - Microbiology 2022Quote: ... were loaded onto an ion exchange column (HiTrap™ Q HP 1 mL, GE Healthcare) equilibrated and washed in the same buffer ...
-
bioRxiv - Microbiology 2023Quote: ... The soluble fraction was loaded onto a StrepTap HP 1 mL affinity column (GE Healthcare) at 4°C previously equilibrated with lysis buffer ...
-
bioRxiv - Immunology 2023Quote: ... The protein solution was loaded on to a 1 ml Mono S column (GE Healthcare), eluted with a 20-bed volume linear gradient from 0 to 500 mM NaCl ...
-
bioRxiv - Synthetic Biology 2022Quote: ... for 1-2 minutes in darkness then exposed and imaged using an Amersham™ Imager 600 (GE Healthcare).
-
bioRxiv - Biochemistry 2021Quote: ... diluted to 1 mL with buffer B and added immediately onto an anion exchange resin (Q resin; GE Healthcare; 0.2 mL; equilibrated in buffer H) and incubated (5 min) ...
-
bioRxiv - Neuroscience 2022Quote: ... distilled water was replaced with a 1:1 dilute of non-ionic iodine Omnipaque 350 contrast agent (Iohexol, 350 mg iodine/ml; GE Healthcare AS) in normal saline via 3 ml syringe ...
-
bioRxiv - Immunology 2023Quote: ... to a ratio of 1 to 1 before being layered onto Ficoll Paque (1.077 g/ml; GE Healthcare Europe GmbH, Freiburg, Germany). After centrifugation (800 x g for 25 min) ...
-
bioRxiv - Cell Biology 2019Quote: ... adjusted to 100 mM Tris-HCl pH 8.0 and 1 mM EDTA and loaded onto a StrepTrap HP column (GE Healthcare) pre-equilibrated in 100 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Microbiology 2022Quote: ... 1 mL of the resulting supernatant was incubated for 1 hour at 4°C on constant agitation of 1,000 rpm with 100 µL glutathione sepharose (GS) resin (GE Healthcare), pre-equilibrated in buffer F ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... Samples were homogenised by bead beating at 4°C in 500 μl Tris-HCl lysis buffer (100 mM, pH 6.8) containing 1% Protease Inhibitor Mix (GE Healthcare). A full and detailed description of the protocol for 2-dimensional gel electrophoresis (2-DE ...
-
bioRxiv - Bioengineering 2019Quote: ... 2 mL of human buffy coat/fresh blood mixed well with 2mL of phosphate-buffed saline (PBS) and then carefully layered on top of 2 mL of Ficoll (GE Healthcare Life Sciences, US) inside a 10ml centrifuge tube without mixing ...
-
bioRxiv - Immunology 2022Quote: ... plus ATP (100 μM) (GE healthcare). After mixing ...
-
bioRxiv - Biochemistry 2021Quote: ... 100 μL Benzamidine-Sepharose (GE Healthcare) was then added ...
-
bioRxiv - Molecular Biology 2022Quote: ... the supernatant was transferred to a new tube and mixed with 20 μl of home-made SPRI beads (equivalent of 1 ml of Sera-Mag Magnetic SpeedBeads, carboxylated, 1 μm, 3 EDAC/PA5 (GE Healthcare Life Sciences) in 50 ml of binding buffer containing 10 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Biophysics 2021Quote: ... lysed protein was purified by cation exchange using a 1 mL HiTrap SP HP (GE Healthcare) in protein buffer (50 mM Tris-HCl pH 7.0 ...
-
bioRxiv - Immunology 2019Quote: ... reaction mixture was applied to a 1 mL HiTrap KappaSelect affinity column (GE Healthcare Life Sciences). All affinity purification steps were carried out by connecting the affinity column to a peristaltic pump with flow rate of 1ml/min ...
-
bioRxiv - Molecular Biology 2020Quote: ... Ion exchange experiments were performed on a Hitrap™ Q HP (1 mL) column (GE healthcare) with ion exchange buffer A and ion exchange buffer B (20 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2019Quote: ... Reaction products were separated by ion-exchange chromatography (1 mL Hitrap Q HP, GE Life Sciences) using a gradient from 0.2 to 2 M ammonium acetate ...
-
bioRxiv - Biochemistry 2020Quote: ... The cleared supernatant was loaded onto two HisTrap HP 1 mL columns (GE Healthcare, Chicago, IL) mounted in series and equilibrated with Buffer A ...
-
bioRxiv - Biochemistry 2020Quote: ... 25 mM HEPES/NaOH pH 8) into a 1 mL HiTrap Heparin HP column (GE Healthcare). This column was further washed with buffer NT.A ...
-
bioRxiv - Biochemistry 2020Quote: ... The enzyme was purified using a 1 ml HisTrap FF column (GE Healthcare, Amersham, United Kingdom) with imidazole gradient elution and an S200 16/60 gel filtration column (Pharmacia Biotech ...
-
bioRxiv - Biochemistry 2020Quote: ... The enzyme was purified using a 1 ml HisTrap FF column (GE Healthcare, Amersham, United Kingdom). The enzyme was dialysed into 20 mM Bis-Tris propane ...
-
bioRxiv - Cell Biology 2021Quote: ... Cleared lysate was incubated with 1 mL IgG Sepharose beads suspension (6 Fast Flow, GE Healthcare) pre-rinsed with buffer for 20 ml lysate on a rotating wheel at 4°C for 1 h ...
-
bioRxiv - Systems Biology 2020Quote: ... Tag-free NCK2 proteins were further purified using a 1 ml HisTrap FF column (GE Healthcare) to remove free His-tagged GST and TEV as well as remaining impurities ...
-
bioRxiv - Microbiology 2020Quote: ... The VHHs were purified from the solution using a 1 mL HisTrap HP column (GE Healthcare). To elute the bound VHHs a linear imidazole gradient starting from 20 mM and ending at 500 mM imidazole in binding buffer over a total volume of 20 mL was used ...
-
bioRxiv - Microbiology 2020Quote: ... Recombinant protein was purified using a 1 ml HisTrap FF column (GE Healthcare, Amersham, United Kingdom) with imidazole gradient elution ...
-
bioRxiv - Microbiology 2020Quote: ... Soluble extracts were mixed with 1 mL of glutathione agarose beads (catalogue number # 17075601, GE Healthcare) and incubated for 2 h at 4°C with gentle agitation ...