Labshake search
Citations for GE Life Sciences :
201 - 250 of 1020 citations for Corticosterone 17 Deoxycortisol CLIA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: ... Preparative Superdex S200 (catalog no. 17-1043-01) for gel filtration was obtained from GE Healthcare. ATPase activity was measured with the PiColorLock™ phosphate detection system kit (Expedeon) ...
-
bioRxiv - Biochemistry 2023Quote: ... The protein eluate was captured by HiTrap IMAC column (17-5248-01, GE Healthcare, Chicago, IL) and eluted by IMAC-B buffer (50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... concentrated in a 30 kDa MWCO Vivaspin 6 centrifuge tube (GE Healthcare, Cat# 28-9323-17), and loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... Clarified dialysate was bound to a MonoS cation exchange column (GE Healthcare, Cat# 17-5168-01) equilibrated with buffer containing 20 mM Tris [pH 8.0] ...
-
bioRxiv - Cell Biology 2023Quote: ... concentrated in a 30 kDa MWCO Vivaspin 6 centrifuge tube (GE Healthcare, Cat# 28-9323-17), and loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare ...
-
bioRxiv - Genomics 2023Quote: ... 167 mM NaCl) and pre-cleared with protein-A-Sepharose beads (GE Healthcare 17-5280-02) for 30 min at 4°C ...
-
bioRxiv - Biochemistry 2023Quote: ... Supernatant was then circulated over 5 mL HiTrap Chelating column (GE Healthcare, Cat# 17-0409-01) that was inoculated with 100mM CoCl2 for ten minutes ...
-
bioRxiv - Cell Biology 2023Quote: ... The protein eluate was captured by HiTrap IMAC column (17-5248-01, GE Healthcare, Chicago, IL) and eluted by IMAC-B buffer (50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Stock Percoll was prepared by combining 9 parts of Percoll (cat# 17-0891-02, GE healthcare) with 1 part of clear (without phenol red ...
-
bioRxiv - Biochemistry 2023Quote: ... the cleared lysate was incubated with 500 µL glutathione agarose slurry (GE Healthcare, #17-0756-01) (resuspended 1:1 in lysis buffer ...
-
bioRxiv - Immunology 2024Quote: ... The oligonucleotide-DBCO was purified via Illustra NAP column (GE Healthcare Life Sciences, #17-0852-02), eluted with sterile water ...
-
bioRxiv - Biochemistry 2023Quote: ... The soluble cell lysates were applied on a Ni-sepharose excel (GE Healthcare, #17-3712-01), packed in a column of 4 ml bed volume with Sl1 buffer buffer (20mM Tris ...
-
bioRxiv - Cancer Biology 2021Quote: ... Ficoll-PaqueTM PLUS (17-1440-02) to isolate PBMCs from buffy coats was purchased from GE Healthcare.
-
bioRxiv - Microbiology 2020Quote: ... Dead cells and debris were then removed by centrifugation in 37.5% Percoll (GE Healthcare, 17-0891-02) at 2000g for 20 minutes ...
-
bioRxiv - Molecular Biology 2020Quote: ... electrophoresed at 17 W for 70 min and transferred onto an Amersham Hybond-N membrane (GE Healthcare) using the Trans-blot SD semi-dry transfer cell (Biorad ...
-
bioRxiv - Molecular Biology 2020Quote: ... layered (appr. 35 mL per tube) onto 15 mL Ficoll-Paque PLUS (GE Healthcare 17-1440-02) using SepMate-50 tubes (Stem Cell Technologies 85450) ...
-
bioRxiv - Biophysics 2020Quote: ... the sample supernatant fraction was incubated with 1 ml Glutathione Sepharose 4B (GE Healthcare, 17-0756-01) for 3 h at 4 °C to bind GST-tagged proteins ...
-
bioRxiv - Biochemistry 2020Quote: ... The filtered sample was applied to a 5 mL HisTrap HP column (GE Healthcare, #17-5248-02), pre-equilibrated with Buffer N and 40 mM imidazole using a peristaltic pump ...
-
bioRxiv - Bioengineering 2021Quote: ... and the supernatant is filtrated and applied to HisTrap™ FF (17-5319-01, GE healthcare, USA) for preliminary purification ...
-
bioRxiv - Biochemistry 2020Quote: ... DBCO beads were synthesized in house: NHS-activated Sepharose™ fast flow (#17-0906-01, GE Healthcare) was incubated to varying concentrations of dibenzocyclooctyne-amine (DBCO-amine ...
-
bioRxiv - Neuroscience 2021Quote: ... Samples were run on a HiPrep S16/60 Sephacryl S-200 HR (GE Healthcare, #17-1166-01) to separate the proteins by molecular weights and then verified by SDS-PAGE (Figure S1) ...
-
bioRxiv - Cancer Biology 2020Quote: ... Mononuclear cells (MNC) were extracted from fresh BM using Ficoll-Paque Plus (GE Healthcare, #17-1440-02). Bone marrow MNCs were also extracted from two patients (ALL10 and ALL12 ...
-
bioRxiv - Biochemistry 2021Quote: ... the supernatant was loaded onto a HisTrap column (5 mL, cat. No. 17-5248-01, GE Healthcare) pre-equilibrated with lysis buffer ...
-
bioRxiv - Neuroscience 2020Quote: ... Filtered supernatant was passed through pre-equilibrated Hitrap Heparin columns (#17-0406-01; Ge HealthCare Life science), followed by a wash with Wash Buffer 1 (20 mM Tris ...
-
bioRxiv - Cell Biology 2021Quote: ... The immuno-complexes were collected with 50 μl of protein A sepharose (17-0780-01, GE Healthcare) at 4 °C for two hours with rotation ...
-
bioRxiv - Cancer Biology 2021Quote: ... 10 µl of equilibrated in lysis buffer His Mag Sepharose beads Ni (GE28-9799-17, GE Healthcare) was added to each sample and kept on a roller overnight ...
-
bioRxiv - Cell Biology 2022Quote: ... This was then coupled onto NHS-ester Sepharose 4 Fast Flow resin (GE Healthcare, 17-0906-01) for 4 h at 4°C ...
-
bioRxiv - Cell Biology 2022Quote: ... The clarified lysates were incubated with glutathione sepharose (1 ml bed volume; GE Healthcare #17-0756-01), washed and eluted by the addition of 2 x 1.5 ml of 10 mM reduced L-glutathione (Sigma #T6066 ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... was added to glass slides previously treated with Repel Silane (GE Healthcare Life Sciences, 17-1332-01) and washed with ethanol ...
-
bioRxiv - Cancer Biology 2020Quote: ... cells were further purified by centrifugation over a Percoll gradient (GE Healthcare, 17-0891-01, Sigma Aldrich).
-
bioRxiv - Neuroscience 2022Quote: ... Cells were separated from myelin and debris by 30% isotonic percoll gradient (#17-0891-01, GE Healthcare) in Myelin Gradient Buffer (MGB) ...
-
bioRxiv - Immunology 2022Quote: ... The immune cells were obtained by density gradient centrifugation with Percoll (17-0891-09, GE Healthcare, USA) according to the manufacture’s instruction ...
-
bioRxiv - Cancer Biology 2022Quote: ... The supernatant was mixed with 50 µl of streptavidin sepharose (Cat. No. 17-5113-01, GE healthcare), shaking at 4°C for 3 h after being washed with PBS once ...
-
bioRxiv - Immunology 2020Quote: ... Human PBMCs were isolated from the blood by density gradient using Percoll (GE Healthcare, 17-5445-01). PBMCs were washed and resuspended in RPMI 1640 supplemented with 10% FBS.
-
bioRxiv - Plant Biology 2020Quote: The GST- and MBP-fusion proteins were separately purified using Glutathione sepharose (GE Healthcare, 17-5132-01) and Amylose resin (New England Biolabs ...
-
bioRxiv - Molecular Biology 2021Quote: ... the protein was loaded onto a 1 ml HiTrap Heparin HP column (GE Healthcare, 17-0406-01) and eluted with a linear gradient from buffer A (20 mM HEPES-NaOH pH 7.5 ...
-
bioRxiv - Biochemistry 2019Quote: ... Size exclusion using a HiLoad 26/60 Superdex 75 prep grade column (17-1070-01, GE Healthcare) was necessary to further purify IF1 from contaminants of higher molecular weight ...
-
bioRxiv - Immunology 2020Quote: ... The resuspended cells were subjected to lymphocyte enrichment using Ficoll-Paque Plus (17-1440-02, GE Healthcare). The decidual leukocytes were further purified by fluorescent activated cell sorting with 7-AAD (420404 ...
-
bioRxiv - Biochemistry 2021Quote: ... and loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris [pH 8.0] ...
-
bioRxiv - Biochemistry 2021Quote: ... Clarified dialysate was then bound to a MonoS cation exchange column (GE Healthcare, Cat# 17-5168-01) equilibrated in 20 mM Tris [pH 8.0] ...
-
bioRxiv - Immunology 2021Quote: ... IFN-α2 protein was column-purified using Nap-5 columns (GE Healthcare, Chicago, IL; #17-0853-01), incubated with 2.5ul serum ...
-
bioRxiv - Immunology 2021Quote: Human PBMCs were isolated by density gradient centrifugation using Ficoll-Paque (GE Healthcare, Cat#17-5442-03). B cells were purified by negative selection (Miltenyi Biotec ...
-
bioRxiv - Microbiology 2021Quote: ... and followed by Superose 6 10/300 gel filtration column chromatography (GE Healthcare, Cat# 17-5172-01). Proteins were then concentrated and the concentrations were determined using BCA protein concentration kit (Pierce ...
-
bioRxiv - Neuroscience 2022Quote: ... GST beads - (Glutathione Sepharose 4b beads, particle size 45 µm - 165 µm, GE Healthcare 17-0756-05) were incubated with the lysate overnight ...
-
bioRxiv - Biochemistry 2022Quote: ... Eluted samples were further purified using the HiTrap™ Q HP column (GE Healthcare, 17-1154-01). The His-LC3B-tag was cleaved using human ATG4B protease at 25°C overnight45 ...
-
bioRxiv - Cell Biology 2022Quote: ... and then combined with 60 μl of washed Protein A–Sepharose beads (17-0780-01, GE Healthcare) for 1 hour on a rotator at 4°C ...
-
bioRxiv - Plant Biology 2022Quote: ... The recombinant protein GST-LSH10 was purified using Glutathione Sepharose 4B beads (GE Healthcare, 17-0756-01) according to the manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2023Quote: ... The supernatant was collected and mixed with fresh 80% Percoll (GE Healthcare, Cat. no. 17-5445-02) prepared in mitochondrial dilution buffer (1000 mM sucrose ...
-
bioRxiv - Molecular Biology 2022Quote: ... Clarified supernatants were then incubated with 150 mL slurry of IgG beads (GE Healthcare, 17-0969-02) for 2h at 4 °C on a turning wheel ...
-
bioRxiv - Neuroscience 2022Quote: ... myelin was removed by resuspending pelleted cells into 30% isotonic Percoll (GE Healthcare, Cat#17-5445-02) and centrifuging at 300g for 15 minutes at 4°C ...