Labshake search
Citations for GE Life Sciences :
1 - 50 of 200 citations for 7 Phenyl acetamido deacetoxy cephalosporanic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2022Quote: ... hydrophobic chromatography on a phenyl-sepharose column (HiTrap Phenyl HP, GE Healthcare) and size exclusion chromatography on an analytical HiLoad 16/60 Superdex 75 (HiLoad 16/600 Superdex 75 pg ...
-
bioRxiv - Biophysics 2021Quote: ... 50 mM Bis-Tris pH 7) and further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction chromatography (HIC) column (GE Healthcare) and eluted against buffer D (50 mM Bis-Tris pH 7) ...
-
bioRxiv - Neuroscience 2022Quote: ... 50 mM Bis-Tris pH 7) and further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction chromatography (HIC) column (GE Healthcare) and eluted against buffer D (50 mM Bis-Tris pH 7) ...
-
bioRxiv - Plant Biology 2023Quote: ... Recombinant CaM was purified using phenyl-sepharose resin (Phenyl Sepharose® 6 Fast Flow, GE Healthcare Inc.) as described (Bender et al. ...
-
Improved Activity and Kinetics of Endoglucanase Biofuel Enzyme with Addition of an AzoTAB SurfactantbioRxiv - Bioengineering 2023Quote: ... HiTrap Phenyl HP (GE Healthcare, 17-1351-01) hydrophobic column was used to obtain β-glucosidase fraction ...
-
bioRxiv - Microbiology 2021Quote: ... followed by another purification using Phenyl Sepharose (GE Healthcare, USA).
-
bioRxiv - Immunology 2021Quote: ... and hydrophobic interactions with a HiTrap Phenyl HP column (GE healthcare. The individual TCR δ- and γ-chains of the VD1G9 TCR were ordered (IDT) ...
-
bioRxiv - Biophysics 2022Quote: ... The protein solution was applied to a Phenyl-sepharose HP (GE Healthcare) column equilibrated with 20 mM MES-NaOH pH 6.0 ...
-
bioRxiv - Molecular Biology 2022Quote: ... CaM was initially purified by affinity to phenyl sepharose (GE Life Sciences) in the presence of 5 mM CaCl2 ...
-
bioRxiv - Immunology 2023Quote: ... Phenyl-Sepharose Fast Flow (low sub) (GE Healthcare Life Sciences, Uppsala, Sweden) was added and supernatants gently mixed in 4°C for 1.5 h ...
-
bioRxiv - Cell Biology 2019Quote: ... Phenyl-Superose HR5/5 and Superose 12 HR10/30 were from GE Healthcare.
-
bioRxiv - Biophysics 2022Quote: ... the solution was loaded onto a 10 ml Phenyl-sepharose HP (GE Healthcare) column equilibrated with 20 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Biophysics 2022Quote: ... the solution was loaded onto a 10 ml Phenyl-sepharose HP (GE Healthcare) column equilibrated with 20 mM MOPS-NaOH pH 6.7 ...
-
bioRxiv - Biochemistry 2023Quote: ... hydrophobic interaction chromatography (HIC) on a 5-ml Phenyl-Sepharose column (GE Healthcare), and gel filtration on a Superdex 75 16/600 (GE Healthcare) ...
-
bioRxiv - Microbiology 2020Quote: ... The cell free supernatant was loaded onto a 5 ml HiTrap Phenyl FF (GE Healthcare) and protein was eluted by using a linear reverse gradient to 100 mM NaCl over 90 min at a flow rate of 2.5 ml/min ...
-
bioRxiv - Biochemistry 2019Quote: ... protein supernatant was bound to a phenyl sepharose column (High Load FF 16/10, GE Healthcare). The column was washed with buffer C and protein eluted with 30% ethanol in water ...
-
bioRxiv - Biochemistry 2020Quote: ... 1.5 M (NH4)2SO4) and was loaded on a 50 ml Phenyl Sepharose column (GE Healthcare). After one column volume wash step the tRNAs were eluted with a linear gradient of Phe-sepharose B buffer (20 mM NaOAc ...
-
bioRxiv - Biophysics 2022Quote: ... A second purification step was performed by hydrophobic interaction chromatography (HiTrap Phenyl HP column, GE Healthcare), where OCP was eluted in 40 mM Tris-HCl pH 8 ...
-
bioRxiv - Plant Biology 2022Quote: ... The sample was finally subjected to hydrophobic interaction chromatography using a phenyl Sepharose column (GE Healthcare) equilibrated in buffer A (50 mM Tris pH 7.5 ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were further purified using an AKTA FPLC system with HiTrap-Phenyl-HP column (GE Healthcare) and Superdex 200 size exclusion chromatography ...
-
bioRxiv - Molecular Biology 2021Quote: ... StuI was further purified by hydrophobic interaction chromatography in a HiTrap Phenyl HP column (GE Healthcare). The ion-exchange chromatography were performed as a linear gradient from 20 mM Tris ...
-
bioRxiv - Biochemistry 2021Quote: ... followed by hydrophobic interaction chromatography (HIC) using a 5 mL HiTrap Phenyl FF (HS) column (GE Healthcare). For the ion exchange procedure ...
-
bioRxiv - Microbiology 2020Quote: ... the supernatant was loaded on a HiLoad 16/10 Phenyl Sepharose HP (GE Healthcare® Life Sciences) column ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: The resulting supernatant was checked for activity prior to being applied to a 75mL Phenyl Sepharose (GE Healthcare) resin equilibrated in Buffer B (1 M ammonium sulfate ...
-
bioRxiv - Microbiology 2020Quote: ... 7 cm strips (GE Healthcare).
-
bioRxiv - Microbiology 2021Quote: ... (7) Superdex 75 resin (GE Healthcare) chromatography using an isocratic elution in Tris buffer B and (8 ...
-
Intra-mitochondrial proteostasis is directly coupled to alpha-synuclein and Amyloid β 1-42 pathologybioRxiv - Neuroscience 2020Quote: ... Alpha-synuclein was then further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction column (GE Healthcare) (76) ...
-
bioRxiv - Biochemistry 2020Quote: ... were pooled and supplemented with ammonium sulfate to a final concentration of 1.5M and loaded on a 5ml pre-packed HiTrap Phenyl HP column (GE Healthcare) equilibrated with buffer A (100mM Tris pH 7.3 ...
-
bioRxiv - Biochemistry 2022Quote: ... the affinity-purified Pvs25 protein was applied to hydrophobic interaction chromatography (HIC) (HiTrap Phenyl HP; 5 mL resin, GE Healthcare) In detail ...
-
bioRxiv - Plant Biology 2021Quote: ... was added to the supernatant to dilute the ammonium sulfate concentration to 0.5 M and the solution was applied to pre-equilibrated hydrophobic column after passing through a 0.22 μm filter (Hitrap phenyl, GE Healthcare). Proteins were eluted by an ammonium sulfate gradient from 0.5 M to 0 M with ten column volumes ...
-
bioRxiv - Biochemistry 2021Quote: ... a hydrophobic interaction chromatography using a linear decreasing (NH4)2SO4 gradient (from 1.5 M to 0 M) (HiTrap HIC phenyl column, GE Healthcare) was applied to the mixture ...
-
bioRxiv - Biophysics 2020Quote: ... the pH of the aSyn sample was adjusted to pH 7 and filtered through a 0.22 μm filter before being loaded onto a HiPrep Phenyl FF 16/10 (High Sub) column (GE Healthcare, Sweden) and eluted in HIC buffer A (50 mM Bis-Tris ...
-
bioRxiv - Biophysics 2019Quote: ... aSyn was then further purified on a HiPrep Phenyl FF 16/10 (High Sub) hydrophobic interaction chromatography (HIC) column (GE Healthcare). aSyn was extensively dialysed against 20 mM Tris pH 7.2 and concentrated using 10 k MWCO amicon centrifugal filtration devices (Merck KGaA ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... for isoelectric focusing of samples loaded on 7 cm pH 4-7 Immobiline DryStrips (GE Healthcare, Uppsala, Sweden). We rehydrated each strip for 48 hours ...
-
bioRxiv - Biochemistry 2021Quote: ... and STD samples were mixed and the rehydration solution (7 M urea, 2 M thiourea, 4% CHAPS, 0.5% IPG Buffer 4-7 [GE Healthcare]) was added before overnight IPG-strips passive rehydration (pH gradient 4-7 ...
-
bioRxiv - Biochemistry 2020Quote: ... 100 μl of purified sample (3.8 mg/mL TbMORN1(7-15) and 2.6 mg/ml TgMORN1(7-15)) were injected onto a Superdex 200 10/300 (GE Healthcare) column and the flow rate was set to 0.5 ml/min ...
-
bioRxiv - Biophysics 2021Quote: ... pH 7 using PD 10 columns (GE Healthcare) and diluted to a final concentration of 20 μM ...
-
Gatekeeper helix activates Golgi SM protein Sly1 and directly mediates close-range vesicle tetheringbioRxiv - Cell Biology 2020Quote: ... pH 7) using a PD-10 column (GE Healthcare). Precipitated material was removed by centrifugation at 10,000 × g for 10 minutes and soluble protein were diluted or concentrated to ∼2.4 mg/mL ...
-
bioRxiv - Biochemistry 2022Quote: ... COS-7 cells were cultured in DMEM (GE Healthcare) supplemented with FCS (PAN-Biotech ...
-
bioRxiv - Microbiology 2021Quote: ... Data were collected using Unicorn 7 software (GE Healthcare Biosciences).
-
bioRxiv - Evolutionary Biology 2019Quote: ... We used a Vivid 7 echocardiographic system (GE Healthcare, USA) with an 11 MHz phased array pediatric transducer operating at a frame rate of 60 Hz ...
-
bioRxiv - Biochemistry 2020Quote: ... Nickelnitrilotriacetic acid-agarose was from GE Healthcare. Deidentified ...
-
bioRxiv - Microbiology 2019Quote: ... Proteins were loaded into 7 cm IPG Strips 3-10 (GE Healthcare) by overnight passive rehydration ...
-
bioRxiv - Plant Biology 2021Quote: ... The pellets were resuspended in buffer containing 7 M urea (GE Healthcare), 2 M thiourea (GE Healthcare) ...
-
bioRxiv - Cancer Biology 2019Quote: ... and 7 μL samples were spotted on Whatman DE81 paper (GE Healthcare). The unincorporated nucleotides were washed four times with 0.5 M Na2HPO4 ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... Using a Vivid 7 echocardiography device (GE Healthcare Life Sciences, Chalfont, UK) and a 12-MHz linear transducer ...
-
bioRxiv - Microbiology 2019Quote: ... IEF was performed using 24 cm 3–7 NL Immobiline DryStrip (GE Healthcare) in an IPGphor unit (GE Healthcare ...
-
bioRxiv - Microbiology 2019Quote: ... IEF was performed in 24 cm 4–7 NL Immobiline DryStrip (GE Healthcare) in an IPGphor unit (GE Healthcare ...
-
bioRxiv - Immunology 2019Quote: ... placed on Ficoll-Paque Plus (ratio 7:3) (GE Healthcare Life Sciences, 17144003), and centrifuged for 20 min at 1800 rpm at room temperature ...
-
bioRxiv - Cell Biology 2021Quote: ... HeLa and COS-7 cells were grown in high-glucose DMEM (GE Healthcare) supplemented with 10% bovine calf serum (GE Healthcare) ...