Labshake search
Citations for GE Life Sciences :
651 - 700 of 3826 citations for 6 Quinoxalinol 1 2 3 4 tetrahydro 1 4 dimethyl 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2019Quote: Blood was collected at the Northwest Assistance Ministries Clinic (Houston, TX) and PBMCs were isolated from whole blood within 4 h of collection using Ficoll Paque plus (GE Healthcare) and frozen down in 7% DMSO in fetal bovine serum and cooled at −1°C/min in a freezing container (Nalgene ...
-
bioRxiv - Cell Biology 2019Quote: ... Extracts were clarified by centrifugation at 40,000 g for 10 min at 4 °C and the proteins were purified using a 5 ml GSTrap column (GE Healthcare) and subsequent size exclusion chromatography on a Superdex 200 16/60 column vs ...
-
bioRxiv - Immunology 2020Quote: ... The cell lysates were incubated with rotation at 4°C first for 45 min with antibodies to FLAG and then for 45 min with protein A–Sepharose (GE Healthcare). The resulting immunoprecipitates were subjected to immunoblot analysis.
-
bioRxiv - Immunology 2020Quote: ... The membrane was incubated first with primary antibodies for 24 h at 4°C and then with horseradish peroxidase– conjugated secondary antibodies (GE Healthcare) for 1 h at room temperature ...
-
bioRxiv - Cell Biology 2020Quote: ... lysates were mixed with 5 μl rabbit polyclonal anti-GM130 serum or 5 μl pre-immune serum for 60 min at 4°C and incubated with protein A-Sepharose (GE Healthcare) for additional 60 min ...
-
bioRxiv - Biochemistry 2020Quote: ... After concentration by spin filtration to 4-5 mL pro-rhodesain was loaded onto a HiLoad 16/600 Superdex 75 pg column (GE Healthcare), and purified by SEC (0.5 mL/min ...
-
bioRxiv - Immunology 2020Quote: ... Samples were separated by protein electrophoresis at 120 V for 2 h using 10% Bis-Tris pre-cast gels (NuPage) and transferred overnight at 4°C onto Hybond-P PVDF membranes (GE Healthcare). After blocking in ECL blocking agent (GE Healthcare) ...
-
bioRxiv - Biophysics 2019Quote: ... and protein was released from the resin by PreScission Protease (PPX) action at 4 °C overnight and further purified on a Superdex 200 column (GE Healthcare) equilibrated in SEC buffer (20 mM Tris pH 7.5 ...
-
bioRxiv - Biochemistry 2020Quote: ... Cell extract was clarified by ultracentrifugation at 140 000 x g at 4 °C for 45 min and recombinant CNOT7 protein was purified automatically using ÄKTAxpress FPLC system (GE Healthcare). The following protocol was used for automated purification ...
-
bioRxiv - Biophysics 2019Quote: ... The resulting suspensions were centrifuged (13000 rpm for 35 min at 4°C) and the supernatants were applied to an HisTrap HP column (GE Healthcare) previously equilibrated with loading buffer (20 mM HEPES ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Between 3-20 µg of total protein per sample were resolved by SDS-PAGE (4-20% gels) and transferred to Amersham Hybond P 0.45 PVDF blotting membranes (GE Healthcare, 10600023). Membranes were blocked overnight at 4 °C in 5% milk or 5% BSA in PBST ...
-
bioRxiv - Biochemistry 2021Quote: ... The lysate was clarified by centrifugation at 35000 g for 30 minutes at 4° C and the supernatant was loaded onto a pre-equilibrated HiTrap Chelating HP column charged with nickel ions (GE Healthcare). The column was washed extensively with wash buffer (20 mM Tris pH 7.9 ...
-
bioRxiv - Cell Biology 2021Quote: ... Membranes were blocked in non-fat 4% milk in TBS/T and incubated with primary and HRP-conjugated secondary (GE Healthcare) antibodies ...
-
bioRxiv - Biochemistry 2021Quote: ... spun at max speed for 30 min in a bench-top centrifuge (at 4°C) and finally loaded on a Superdex200 16/60 (GE Healthcare) previously equilibrated in MPS1 buffer (250 mM NaCl ...
-
bioRxiv - Biochemistry 2021Quote: ... samples were concentrated in 10K MWCO centricons (PAL Corporation) (5000rpm [3214xg] at 4°C) and applied on a Superdex200 HiLoad 16/600 column (GE Healthcare) using 25 mM Hepes pH 7.6 ...
-
bioRxiv - Cell Biology 2022Quote: ... 5 min at 4 °C followed by an anion exchange chromatography loading the supernatant on a HiTrap Q HP 5 ml column (GE Healthcare) and intensive wash step of 20 column volumes with ion exchange buffer A ...
-
bioRxiv - Immunology 2021Quote: ... 13,200 rpm at 4°C) and the resulting supernatant was precleared for 30 min using rProtein A Sepharose fast-flow beads (GE Healthcare). The precleared lysate was incubated with HLA-DR specific antibody L243 (43 ...
-
bioRxiv - Cell Biology 2020Quote: ... 100 – 300 µg protein was loaded on 10 – 12% SDS-PAGE and transferred at 4°C overnight to a nitrocellulose blotting membrane (A29434119, GE Healthcare) in transfer buffer (25 mM Tris pH 8 ...
-
bioRxiv - Genetics 2021Quote: ... and then incubated with primary antibodies overnight at 4°C and then again with horseradish peroxidase–linked secondary antibodies (GE Healthcare) in PBST with 5% dry milk for 1 hour at RT ...
-
bioRxiv - Biochemistry 2020Quote: ... All purification steps were carried out at 4°C using the ÄKTA Pure fast protein liquid chromatography (FPLC) system (GE healthcare). Protein purity was assessed by SDS-PAGE ...
-
bioRxiv - Biophysics 2021Quote: ... These solutions were prepared either by dialysis against the buffer at 4°C or by passage through PD-10 desalting columns (GE Healthcare). Protein concentrations were measured spectrophotometrically using known values for the extinction coefficient ...
-
bioRxiv - Microbiology 2019Quote: ... clarified lysates were mixed with 1 µg anti-HA monoclonal antibody and rotated with 30 µl pre-equilibrated Protein G Sepharose 4 Fast Flow resin (GE healthcare) for 3 hours at 4°C ...
-
bioRxiv - Immunology 2021Quote: ... 0.5-1 mL plasma or serum was heat inactivated at 56°C for 45 minutes and incubated overnight with Protein G Sepharose 4 Fast Flow beads (GE Healthcare) at 4°C ...
-
bioRxiv - Molecular Biology 2021Quote: ... Eluted proteins were digested at 4°C with specific proteases and further purified by ion-exchange chromatography using a HiTrap SP HP or monoQ (GE Healthcare) columns and a gradient running from 0% buffer A (40 mM TRIS ...
-
bioRxiv - Neuroscience 2022Quote: ... Aβ42 peptides in the filtrate were further concentrated to ∼50 μM at 4°C and 4000×g with a 5 000 Da Vivaspin concentrator (GE Healthcare). The Aβ42 peptide concentration was calculated using an extinction coefficient of 1400 M-1cm-1 ...
-
bioRxiv - Biophysics 2022Quote: ... The lysate was centrifuged at 4 °C and 20000 g for 30 min and the supernatant applied to a gravity flow column with 4 mL pre-equilibrated Ni-NTA Sepharose resin (GE Healthcare). The column was washed with 50 mL of high-salt Tris-HCL buffer (50 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Neuroscience 2022Quote: ... 1 mg of total protein was pre-cleared for 3h at 4°C by incubation with glutathione-coupled sepharose beads (GE Healthcare) previously equilibrated in Wash buffer 1 (50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biophysics 2022Quote: ... proteins were concentrated by ultrafiltration at 4 °C (MWCO: 10 kDa) and passed over a Superdex 75 26/60 gel filtration column (GE Healthcare) equilibrated in 20 mM sodium phosphate pH 7.4 ...
-
bioRxiv - Microbiology 2022Quote: ... Radioactive signal was visualized by exposing 4 h a Storage Phosphor Screen BAS-IP MS 2040 (Fujifilm) then imaged with a Typhoon FLA 9500 (GE Healthcare).
-
bioRxiv - Plant Biology 2022Quote: ... The lysate was centrifuged at 15557 g for 30 min at 4°C and the supernatant was loaded on a HisTrap column (GE Healthcare) equilibrated in 20 mM HEPES 150 mM NaCl 20 mM imidazole 0.02% NaN3 pH = 7.4) ...
-
bioRxiv - Plant Biology 2022Quote: ... Purification tags were then removed by incubating with 3C protease (10 μg/mg fusion protein) overnight at 4°C followed by passing through tandem Ni2+-NTA and MBP Trap HP columns (GE Healthcare). The flow-through was concentrated as appropriate and loaded on a Superdex 75 26/600 gel filtration column for final purification and buffer exchange into 20 mM HEPES pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... The sample was incubated at 4°C for 30 minutes and further purified using a HiLoad 26/600 Superdex 200 (GE healthcare).
-
bioRxiv - Cell Biology 2022Quote: ... After sonication the lysate was clarified by centrifugation (22 500 rpm/61 236 x g, 20 min, 4 °C) and applied to a HisTrap FF column (GE Healthcare) equilibrated with 10 column volumes (CV ...
-
bioRxiv - Immunology 2023Quote: ... as binding of DH270 UCA chimeric antibodies containing CDRH3 loops identified from the natural BCR database (Figure 4) was analyzed by Surface Plasmon Resonance on a BIAcore 3000 instrument (GE Healthcare). Biotinylated SOSIP Env 10.17DT was immobilized on a CM5 chip coated with streptavidin ...
-
bioRxiv - Biochemistry 2022Quote: ... The fractions that contained BED were concentrated and further purified at 4 °C on a preparative Superdex 75 16/600 size exclusion column (GE Healthcare) equilibrated with 25 mM HEPES.Na pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... All chromatography procedures were carried out at 4°C using either an ÄKTA express or ÄKTA pure chromatography system (GE Healthcare). 1 mL StrepTrapTM HP (cat# 28907546 ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was centrifuged for 30 min at 30000 x g at 4°C and loaded onto a Ni-NTA affinity chromatography column (HisTrap FF crude, GE Healthcare). His-tagged proteins were eluted with a linear gradient of buffer B (50 mM Hepes pH 8 ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was centrifuged for 30min at 30000 x g at 4°C and loaded onto a Ni-NTA affinity chromatography column (HisTrap FF crude, GE Healthcare). His-tagged proteins were eluted with a linear gradient of buffer B (PBS 1X ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was centrifuged for 1h at 20000 x g at 4°C and loaded onto a Ni-NTA affinity chromatography column (HisTrap FF crude, GE Healthcare). His-tagged protein was eluted with a linear gradient of buffer B (50 mM Hepes pH 7 ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was centrifuged for 30min at 30000 x g at 4°C and loaded onto a Ni-NTA affinity chromatography column (HisTrap FF crude, GE Healthcare). The His-tagged protein was eluted with a linear gradient of buffer B (Hepes 50 mM pH 8 ...
-
bioRxiv - Neuroscience 2023Quote: ... Cells were filtered and then pelleted at 300 g for 10 minutes at 4°C before being resuspended in 22% Percoll (GE Healthcare) and centrifuged at 900 g for 20 minutes with acceleration set to 4 and deceleration set to 1 in order to remove cellular debris ...
-
bioRxiv - Molecular Biology 2023Quote: ... and 20-30 μg of protein was electrophoresed on 4-12% (or 12% for OGG1 blot) Bis-Tris gels (Thermo) before transferring to PDVF or nitrocellulose membranes (GE Healthcare). For PAR 10H western blots ...
-
bioRxiv - Biochemistry 2023Quote: ... Gels were run at 4 °C overnight as described above and scanned with GE Amersham Typhoon-5 fluorescence gel and blot scanner (GE Healthcare) with red laser.
-
bioRxiv - Cell Biology 2023Quote: ... and indicated prey proteins at a 5X molar excess to tepsin (mATG8 and/or AP-4 β4 appendage) were incubated with glutathione sepharose resin (GE Healthcare) for 2 hours at 4°C in 20 mM HEPES (pH 7.5) ...
-
bioRxiv - Biochemistry 2023Quote: ... the N-terminal His tag was cleaved by overnight dialysis with TEV protease at 4 °C and purified by size exclusion chromatography (SEC) (HiLoad Superdex-200 16/600 column, GE Healthcare) in CHIP storage buffer (50 mM HEPES ...
-
bioRxiv - Biophysics 2023Quote: ... The mixture was incubated at room temperature for 4 hours and was purified using gel filtration chromatography (ÄKTA with Superdex-200 increase column; GE Healthcare) equilibrated with storage buffer ...
-
bioRxiv - Biophysics 2023Quote: ... 3,000 g × 15 min at 4 °C) and further purified by size-exclusion chromatography (ÄKTA pure system, Superdex-75 Increase 10/300 GL, GE Healthcare). The unfolding and refolding process for GlnBP WT was conducted under the same conditions as described for the GlnBP variants.
-
bioRxiv - Plant Biology 2023Quote: ... DNA was isolated from leaf tissue of 4-wk-old plants by using Illustra Nucleon Phytopure extraction kit reagents (GE Healthcare). DNA was isolated from agarose gel pieces using QIAquick gel extraction kit (Qiagen).
-
bioRxiv - Biochemistry 2023Quote: ... 4°C) and the soluble proteins with His6 tag were purified on 1ml of nickel phosphate loaded sepharose beads (GE Healthcare). Bound proteins were washed in lysis buffer with 25mM imidazole then with 400mM Imidazole ...
-
bioRxiv - Biophysics 2023Quote: ... Q7 or Q20 at a concentration of ~4-7mg/ml were loaded onto an S200 Increase size-exclusion column (Superdex 200 Increase10/300 GL, GE Healthcare) at a flow rate of 0.5 ml min-1 ...