Labshake search
Citations for GE Life Sciences :
3751 - 3800 of 4960 citations for 7 Methyl 1 5 dioxo 1 2 3 5 tetrahydro indolizine 6 carbonitrile since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2023Quote: ... The GST-tagged Bridge domain was purified by affinity chromatography with glutathione-SepharoseTM 4B resins (Cytiva) followed by size exclusion chromatography with Superose 6 10/300 (GE Healthcare) in the running buffer containing 150 mM NaCl and 20 mM HEPES (pH 7.5).
-
bioRxiv - Biophysics 2023Quote: ... The mixed complexes were incubated over night at 4 °C and the formed R2SP complex was separated from excess SPAG1/PIH1D2 using a Superose 6 16/60 XK (GE Healthcare), see Supplementary Information for detailed protocol ...
-
bioRxiv - Biophysics 2023Quote: ... the protein was diluted 10 times with PBS buffer and immobilized on a Nickel Sepharose 6 Fast Flow resin (GE Healthcare). The resin was washed extensively with milliQ water followed by PBS buffer pH 7.4 ...
-
bioRxiv - Molecular Biology 2023Quote: ... The concentrated protein sample was centrifuged at 10,000 × g and 4°C for 10 min before the supernatant was loaded onto a lysis buffer equilibrated Superose 6 increase 10/300 GL column (GE Healthcare), connected to a 1260 Bioinert Infinity LC system and equipped with a multi-angle light scattering detector (miniDawn 3141MD3 ...
-
bioRxiv - Biophysics 2023Quote: ... The protein was further concentrated by a 100-kDa cutoff concentrator (Milipore) and loaded onto a Superose 6 increase 10/300 column (GE Healthcare) running in lysis buffer with 1 mM MgCl2 and 0.03% digitonin ...
-
bioRxiv - Biophysics 2023Quote: ... The protein was further concentrated by a 100-kDa cutoff concentrator (Milipore) and loaded onto a Superose 6 increase 10/300 column (GE Healthcare) running in lysis buffer with 0.03% digitonin ...
-
bioRxiv - Biochemistry 2023Quote: ... The sample was concentrated with a 100 kDa cutoff concentrator to 500 μL and loaded on a Superose 6 Increase 10/300 column (GE Healthcare) equilibrated with gel filtration buffer (20 mM Tris-HCl pH 7.4 ...
-
bioRxiv - Biochemistry 2023Quote: ... the soluble fraction was passed over the appropriate affinity resin of Strep-Tactin XT Superflow (IBA) or Ni Sepharose 6 Fast Flow affinity resin (GE Healthcare), eluted with wash buffer (50 mM Tris–HCl pH 8.0 ...
-
bioRxiv - Biophysics 2023Quote: Size exclusion chromatography (SEC) was performed using ÄKTAprocess 6 mm Std system controlled by the Unicorn 7.0 software (GE Healthcare, Sweden). Sepharose 6 Fast Flow beads (GE Healthcare ...
-
bioRxiv - Cell Biology 2022Quote: Cellular lysates were separated on a Superose 6 HR 10/30 size-exclusion column and an AKTA Purifier protein purification system (GE Healthcare), essentially as described previously(61) ...
-
bioRxiv - Biochemistry 2022Quote: ... The ACE2-induced postfusion S-nanodisc sample was purified by gel filtration chromatography on Superose 6 Increase 10/300 column (GE Healthcare) in a buffer containing 25 mM Tris-HCl ...
-
bioRxiv - Biophysics 2023Quote: ... The concentrated protein sample was further purified by size exclusion chromatography (SEC) using a Superose 6 Increase 10/300 GL (GE Healthcare) column pre-equilibrated with the buffer E (20 mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... After His-tag purification protein was subsequently purified by size exclusion chromatography using a Superose 6 Increase 10/300 column (GE Healthcare). The oligomeric state of CsoSCA-MBP was determined from the Superose 6 Increase chromatogram and a calibration standard (Bio-Rad) ...
-
bioRxiv - Biochemistry 2023Quote: ... The proteins were eluted with HBS containing 200 mM imidazole and further purified using size-exclusion chromatography (Superdex 200 Increase 10/300 or Superose 6 Increase 10/300 columns; GE Healthcare) in 10 mM Tris ...
-
bioRxiv - Plant Biology 2023Quote: ... for 2 hours and then extensively washed with lysis buffer and eluted in lysis buffer with 5mM desthiobiotin and further purified by size-exclusion chromatography with Superose 6 increase 10/300 GL-column (GE Healthcare).
-
bioRxiv - Immunology 2023Quote: ... Plasma lipoproteins were separated using fast-performance liquid chromatography with two Superose 6 10/300 GL columns (GE Healthcare; Boston, MA) on a Shimadzu HPLC system (Columbia ...
-
bioRxiv - Immunology 2023Quote: ... Affinity-purified proteins were incubated with HRV-3C protease to remove purification tags and subsequently purified by size-exclusion-chromatography on a Superose 6 Increase column (GE Healthcare) in TBS
-
bioRxiv - Immunology 2023Quote: ... protein was purified using cell-free culture supernatant by StrepTactin resin (IBA) and by size-exclusion chromatography using Superdex 200 (RBD and NTD) or Superose 6 (S-2P) column (GE Healthcare) in 10 mM Tris pH8 ...
-
bioRxiv - Cell Biology 2023Quote: ... Elution was performed with imidazole and the second step of purification was performed using Superose 6 Increase 10/300 GL gel filtration chromatography (GE Healthcare).
-
bioRxiv - Biochemistry 2023Quote: ... The harvested cells were lysed by pulsed sonication and the soluble fraction was affinity purified using Ni2+-Sepharose (Ni Sepharose 6 Fast Flow, GE Healthcare). The resulting MsLadC variants ...
-
bioRxiv - Biophysics 2023Quote: ... The 6×His-tagged SUMO fusion proteins were purified using a HisTrap™ HP Ni2+ affinity column (GE Healthcare Life Sciences). The fractions containing fusion protein were pooled and exchanged into a SUMO protease cleavage buffer (20 mM Tris-HCl at pH 8.0 ...
-
bioRxiv - Biophysics 2023Quote: ... The eluted sample was concentrated using an Amicon Ultra Centrifugal Filter (MWCO 100 kDa) and purified by Superose 6 Increase 10/300 column (GE Healthcare) pre-equilibrated with buffer containing 20 mM HEPES pH 7.5 ...
-
Faa1 membrane binding drives positive feedback in autophagosome biogenesis via fatty acid activationbioRxiv - Biochemistry 2023Quote: ... The cleaved protein was concentrated and loaded onto a Superose 6 Increase size exclusion chromatography column (10/300 prep grade, GE Healthcare). Elution was carried out with 150 mM NaCl ...
-
bioRxiv - Biochemistry 2023Quote: ... dIgA-604 and SIgA-604 were purified using Ni-NTA beads (Smart-Lifesciences) and a Superose 6 Increase column (GE Healthcare).
-
bioRxiv - Biophysics 2023Quote: ... protein samples were purified by size-exclusion chromatography at 4°C using a Superose 6 10/300 GL column (GE Healthcare), equilibrated with a buffer containing 0.03% (w/v ...
-
bioRxiv - Immunology 2023Quote: ... The S proteins were then separated by chromatography using resin attached with streptavidin and further purified by size exclusion chromatography using a Superose 6 10/300(GE Healthcare) in 20 mM Tris ...
-
bioRxiv - Biophysics 2024Quote: ... The protein was concentrated using a 100 kDa filter to approximately 1 mL and further purified by size-exclusion chromatography at 4°C using a Superose 6 10/300 GL column (GE Healthcare) equilibrated with buffer containing 0.06% digitonin ...
-
bioRxiv - Biochemistry 2024Quote: ... The sample was concentrated to 100 µL using a 100 kDa MWCO concentrator and the concentrate was loaded onto a size-exclusion chromatography (SEC) column (Superose 6 Increase 10/30 GL, GE Healthcare), equilibrated in a buffer composed of 20 mM Tris-Cl (pH 8) ...
-
bioRxiv - Microbiology 2024Quote: ... The fractions containing L–P protein were further purified using a size-exclusion column (Superose 6 Increase 10/300 GL, GE healthcare) equilibrated with size exclusion chromatography (SEC ...
-
bioRxiv - Immunology 2024Quote: ... The S proteins were then separated by chromatography using resin attached with streptavidin and further purified by size exclusion chromatography using a Superose 6 10/300(GE Healthcare) in 20 mM Tris ...
-
bioRxiv - Immunology 2024Quote: ... Fab was purified from clarified culture supernatant six days post-transfection using Ni-NTA affinity chromatography with IMAC Sepharose 6 Fast Flow resin (GE Healthcare). Gel filtration on a Superdex 75 10/300 column (GE Healthcare ...
-
bioRxiv - Biophysics 2021Quote: ... The supernatant was then incubated with 3 ml pre-equilibrated Ni-NTA resin (GE Healthcare, USA).
-
bioRxiv - Microbiology 2019Quote: ... First dimension isoelectric focusing (IEF) run was performed using Ettan IPGphor 3 IEF System (GE Healthcare) according to manufacturer instructions ...
-
bioRxiv - Biophysics 2020Quote: ... the sample was loaded onto a freshly poured 3 mL G50 Sephadex column (GE Life Sciences) equilibrated in CoWB ...
-
bioRxiv - Microbiology 2019Quote: ... Three additional siRNAs targeting the 3’-UTR of KSRP mRNA (siKSRPe) were synthesized (Dharmacon, GE Healthcare) and pooled to a 20 µM stock solution ...
-
bioRxiv - Systems Biology 2023Quote: ... The membrane was washed again 3 times and imaged on an Amersham Imager 600 (GE Healthcare). The primary antibodies used were 1:1000 rabbit anti-SPP1 (Proteintech #22952-1-AP) ...
-
bioRxiv - Biochemistry 2023Quote: ... The supernatant was mixed with 3 ml of IgG Sepharose Fast Flow beads (GE Healthcare, 17096901) equilibrated with CMG buffer/300 mM KCl and incubated for 2 hours at 4°C on a rotating wheel ...
-
bioRxiv - Immunology 2023Quote: ... Eluted protein was concentrated with 3 kDa MWCO filters (Amicon) before size-exclusion chromatography (GE Healthcare). Proteins were stable at 4ºC.
-
bioRxiv - Microbiology 2023Quote: ... Biotin-labelled HCV 3’UTR RNA was immobilized on streptavidin-coated sensor chips (GE Healthcare Lifescience) to a final concentration of 300 Resonance Units (RU)/flow cell ...
-
bioRxiv - Bioengineering 2023Quote: ... An adapter was 3-D printed to allow a GE 9LD transducer (GE Healthcare, Wauwatosa, WI) to be easily attached to or removed from the FASTER device (Fig ...
-
bioRxiv - Immunology 2023Quote: MIL-3 Fab was loaded onto a gel filtration Superdex 200 column 10/30 (GE Healthcare) in 10 mM Tris-HCl ...
-
bioRxiv - Microbiology 2020Quote: ... S protein was purified by running the supernatant through a streptactin column and then by size exclusion chromatography using a Superose 6 increase 10/300 column (GE Healthcare Biosciences). Protein fractions corresponding to the trimeric S protein were collected and concentrated.
-
bioRxiv - Cell Biology 2020Quote: ... Elutions with CAV1 were concentrated and further purified by size exclusion chromatography using Superpose 6 Increase 10/300 GL (GE Healthcare, Illinois) equilibrated with a buffer composed of 200 mM NaCl ...
-
bioRxiv - Immunology 2022Quote: ... BG505 Env trimer was purified from transfected cell supernatants as described47 by 2G12 immunoaffinity and size-exclusion chromatography (SEC) with a Superose 6 16/600 column followed by Superdex 200 Increase 10/300 GL column (GE Life Sciences).
-
bioRxiv - Biochemistry 2019Quote: ... 100 μL of purified protein/complex at 2-5 mg/mL was injected onto a Superdex 200 Increase 10/300 GL or Superose 6 Increase 10/300 GL column (GE Life Sciences) in a buffer containing 20 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2019Quote: Size exclusion chromatography experiments with HeLa cell extracts were performed with a pre-packed Superose 6 10/300 GL column (GE Healthcare ©). The column was equilibrated with buffer A (20 mM Hepes ...
-
bioRxiv - Microbiology 2019Quote: ... The concentrated protein complex was further purified using size-exclusion chromatography with a Superose-6 Increase 10/300-GL (GE Life Sciences) column equilibrated in Buffer B (50 mM HEPES ...
-
bioRxiv - Genomics 2021Quote: ... Neisseria sicca and Neisseria elongata was migrated on a 6% polyacrylamide gel and then transferred onto nitrocellulose membrane (Amersham Hybond™ N+ from GE healthcare). The oligonucleotides were labeled in 5’ by using 5 pmoles of oligonucleotide ...
-
bioRxiv - Cell Biology 2021Quote: ... The eluted Cavin4a-FL and Cavin4b-FL proteins were loaded on size exclusion chromatography column Superose™ 6 Increase 10/300 GL column (GE healthcare) pre-equilibrated with 0.22 μm filtered 50 mM HEPES ...
-
bioRxiv - Microbiology 2020Quote: ... The resulting pellet was resuspended in TET and complexes were further separated by Superose 6 10/300 column chromatography in TET buffer with 150 mM NaCl using an AKTA Pure system (GE Life Sciences). The sample collected from the column was used for microscopy and visualized by SDS-PAGE with silver staining (ProteoSilver™ Plus Silver Stain Kit) ...