Labshake search
Citations for GE Life Sciences :
3551 - 3600 of 5529 citations for Mouse Anti Hantavirus Nucleocapsid Protein Antibody 4958 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... The supernatant was maintained at 4°C for protein purification with a prepared HisTrap HP column (GE Healthcare). Purified protein samples were concentrated using an Amicon 4 centrifugal filtration tube centrifuged for 5 min at 3600 rcf (4 °C) ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Eluted protein was then applied to size-exclusion chromatography (Superdex 200 Increase 10/300 GL column, GE Healthcare) with the buffer containing 25 mM MES pH 6.0 ...
-
bioRxiv - Microbiology 2021Quote: ... FLAG epitope-tagged protein levels were visualized using the Amersham ECL Western blotting detection reagent (GE Healthcare, #GERPN2209). In a parallel gel ...
-
bioRxiv - Molecular Biology 2020Quote: ... Recombinant NS1-6xHis protein was further purified by gel filtration using an AKTA pure chromatograph (GE Healthcare, USA). An XK 16/60 Chromatographic Column ...
-
bioRxiv - Molecular Biology 2020Quote: ... Lysates were clarified by centrifugation and GST-tagged protein were isolated on glutathione sepharose 4B resin (GE Healthcare) at 4°C for 2 hours ...
-
bioRxiv - Plant Biology 2021Quote: ... 20X concentrated protein extract (10 ml) was loaded in an anionic-exchange Q-sepharose column (GE Healthcare, USA) previously equilibrated with 20 mM Tris-HCl pH 7.4 ...
-
bioRxiv - Microbiology 2020Quote: ... Eight days post transfection the supernatant was loaded on the HiTrap protein G HP 1ml column (GE Healthcare) in binding buffer (20 mM sodium phosphate pH 7.0 ...
-
bioRxiv - Neuroscience 2021Quote: ... The supernatant was analyzed by SDS-PAGE and proteins were transferred to a nitrocellulose membrane (GE Healthcare, #BA85). Membranes were incubated for 1 h in a blocking solution (Tris-buffered saline (TBS ...
-
bioRxiv - Cancer Biology 2020Quote: ... Protein was then purified by gel filtration using a Superdex 200 26/600 GL column (GE Life Sciences) before cleaving the His6-SUMO tag with ULP1 enzyme ...
-
bioRxiv - Cancer Biology 2020Quote: ... Proteins were resolved using SDS-PAGE gels and transferred to nitrocellulose membranes (GE Healthcare Life Sciences, cat#10600001) as previously described in [8] ...
-
bioRxiv - Cell Biology 2021Quote: ... The proteins were further purified by size exclusion chromatography (SEC; HiLoad 16/600 Superdex 200 pg, GE Healthcare) in 50 mM phosphate pH 8.0 ...
-
bioRxiv - Cell Biology 2021Quote: ... GST-Bro1V fusion protein and mutants thereof were purified using the Glutathione Sepharose 4B (GE Healthcare, United Kingdom), treated with AcTEV protease (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... the proteins were further purified by size exclusion chromatography (Superdex-75 10/300 GL column; GE Life Sciences) and judged greater than 95% pure by SDS-PAGE analysis.
-
bioRxiv - Cell Biology 2022Quote: ... and 0.1 mg protein were loaded on a Superdex 200 10/300 GL size-exclusion column (GE Healthcare) connected to an ÄKTA pure (GE Healthcare ...
-
bioRxiv - Biochemistry 2022Quote: ... The concentrated protein was subjected to size exclusion chromatography on Superose 6 increase 10/300 column (GE Healthcare).
-
bioRxiv - Biophysics 2022Quote: ... Labeled proteins were separated from free dye molecules by gel filtration using a Superdex 200 column (GE Healthcare)56.
-
bioRxiv - Biochemistry 2022Quote: ... Concentrated protein for Cryo-EM was loaded over a HiLoad 26/600 Superdex 200 pg column (GE Healthcare) using SEC Buffer (25mM HEPES pH 7.2 ...
-
bioRxiv - Biochemistry 2022Quote: ... Then the protein was purified by gel-filtration chromatography using a Superose 6 gel filtration column (GE Healthcare) pre-equilibrated with HBS buffer (10 mM HEPES ...
-
bioRxiv - Biophysics 2022Quote: ... Then the proteins were purified from the lysate with the Ni2+-NTA column of ÄKTA Pure (GE healthcare). Then the proteins were biotinylated using Avidity biotinylation kit and recommended protocol ...
-
bioRxiv - Biochemistry 2022Quote: ... Protein was further purified with gel filtration on a Hi-load 16/60 Superdex-75 column (GE Healthcare) in 25 mM Trizma (pH 7.5) ...
-
bioRxiv - Biochemistry 2022Quote: ... The eluted protein was diluted with lysis buffer before application to a 5ml HiTrap STREP column (GE Healthcare), washed with lysis buffer and eluted using buffer supplemented with 2 mM Desthiobiotin ...
-
bioRxiv - Biochemistry 2022Quote: ... The eluted protein was concentrated and applied to a Superose 6 Increase 10/300 GL column (GE Healthcare) in the same buffer.
-
bioRxiv - Neuroscience 2022Quote: ... Proteins of interest were visualized with the Amersham ECL Detection Reagents (GE Healthcare by SIGMA, Cat. No. RPN2105) or LiteAblot TURBO Extra-Sensitive Chemioluminescent Substrate (EuroClone ...
-
bioRxiv - Microbiology 2022Quote: ... The protein was then further purified by gel filtration using Superose 6 increase 10/300 column (GE Healthcare) in 20 mM Tris pH 8.0 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Protein solution was run at room temperature on a Superdex 75 10/300 GL (GE Healthcare, Piscataway, NJ) column with 2 mg/ml gD1 and a mobile phase composed of Tris- HCl at pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... The protein was run over a size exclusion column (GE Healthcare HiPrep 26/60 Sephacryl S-300 HR) in sizing buffer (50 mM Tris-HCl pH = 8.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... protein digestion was concentrated and applied to a HiLoad™ 16/600 Superdex™ 75pg column (GE Healthcare) in 20 mM Hepes pH 7.5 ...
-
bioRxiv - Microbiology 2020Quote: ... 500 µl of freshly purified protein was loaded on a Superdex 200 10/300 GL column (GE Healthcare) equilibrated with Buffer A ...
-
bioRxiv - Biochemistry 2021Quote: ... The P5CS proteins were further purified through HiLoad 16/600 Superdex 200 pg gel-filtration chromatography (GE Healthcare) in column buffer (25 mM HEPES pH 7.5 and 100 mM KCl) ...
-
bioRxiv - Plant Biology 2021Quote: ... the purified protein was loaded on an analytical size exclusion column (SEC, superdex200 10/300, GE Healthcare, USA) pre-equilibrated with buffer containing 25mM Tris (pH 8.0) ...
-
bioRxiv - Cell Biology 2021Quote: The purified protein was analyzed by Size Exclusion Chromatography (SEC) (Superdex 200 10/30 GL column; GE Healthcare) coupled with multi-angle light scattering (MALS ...
-
bioRxiv - Molecular Biology 2020Quote: ... Proteins were resolved by SDS-PAGE and transferred to Protran nitrocellulose membranes (GE Healthcare Life Sciences, Waukesha, WI), which were incubated at 4°C overnight with primary antibodies ...
-
bioRxiv - Cell Biology 2021Quote: ... DNA fragments encoding APC proteins were inserted into pGEX-5X-1 (GE Healthcare Life Sciences, Pittsburgh, PA, USA). For in vitro transcription and translation reaction ...
-
bioRxiv - Cell Biology 2020Quote: ... Protein transfer from gel to membrane was performed with a 0.45 μm PDVF AmershamTM HybondTM membrane (GE Healthcare, formerly Amersham Biosciences ...
-
bioRxiv - Biochemistry 2021Quote: ... Cleaved DEPTOR protein was then collected and applied to a 5 mL HiTrap Heparin HP column (GE Healthcare) equilibrated with HEP-A buffer (50 mM HEPES pH 8 ...
-
bioRxiv - Biophysics 2021Quote: ... The protein was then injected on a High load superdex 200 16/600 gel filtration column (GE Healthcare) in deuterated PBS buffer pH 7.4 ...
-
bioRxiv - Biophysics 2021Quote: ... The protein was further purified via gel filtration using Superose 6 Increase 10/300 GL column (GE Healthcare) pre-equilibrated with the purification buffer (50 mM Tris-HCl ...
-
bioRxiv - Neuroscience 2022Quote: ... NM- His was purified from the supernatant via IMAC using the ÄKTA pure protein purification system (GE Healthcare) together with a 5 ml HisTrap HP His tag protein purification column (GE Healthcare) ...
-
bioRxiv - Neuroscience 2022Quote: ... The lysate was divided equally and incubated with 50 μl of prewashed 50% Protein G slurry (GE Healthcare) for each condition ...
-
bioRxiv - Immunology 2022Quote: ... Protein was concentrated and further purified by size-exclusion chromatography using Superose 6 16/60 (GE Life Sciences) in a PBS buffer ...
-
bioRxiv - Immunology 2022Quote: ... Protein was further purified by size-exclusion chromatography using a Superose 6 Increase 10/300 column (GE Healthcare) in 2 mM Tris pH 8.0 ...
-
bioRxiv - Immunology 2022Quote: ... 5% glucose) and the proteins purified by affinity chromatography using a HiTrap Heparin High-Performance column (GE Healthcare) and gradient elution (0-100% NaCl ...
-
bioRxiv - Cell Biology 2022Quote: All chromatography steps were performed at 4°C using ÄKTAxpress or ÄKTA pure protein purification systems (GE Healthcare). Firstly ...
-
bioRxiv - Cell Biology 2022Quote: ... All proteins were further purified by gel filtration on a Superdex S200 preparative or analytical column (GE Healthcare).
-
bioRxiv - Biochemistry 2022Quote: ... the labeled KRAS protein was purified by size-exclusion chromatography using 16/60 Superdex75 increase column (GE Healthcare) pre-equilibrated with 20 mM HEPES (pH 7.0) ...
-
bioRxiv - Biophysics 2019Quote: ... Eluted protein was concentrated and further purified by size exclusion chromatography using a Superdex200 column (GE Life Sciences) in 25 mM HEPES pH 7.5 ...
-
bioRxiv - Plant Biology 2019Quote: ... GST-tagged and His-tagged proteins were affinity-purified using glutathione agarose beads (GE Healthcare, Pittsburgh, PA, USA) and Ni-NTA affinity agarose beads (QIAGEN ...
-
bioRxiv - Neuroscience 2019Quote: ... Cleaved protein was concentrated (50 kDa MWCO) and run on a Superdex 200 10/300 column (GE Healthcare) in SEC buffer (20 mM Tris pH 8.0 ...
-
bioRxiv - Molecular Biology 2019Quote: ... The cleaved Cas9 protein was separated from fusion tag on HiLoad Superdex 200 16/60 column (GE Healthcare) in 20 mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2019Quote: ... the concentrated protein sample was applied onto a HiLoad Superdex 200 16/60 prep grade column (GE Healthcare) equilibrated with SEC buffer (25 mM CAPS pH 10 ...