Labshake search
Citations for GE Life Sciences :
301 - 350 of 4352 citations for Recombinant Human Chemokine C X C Motif Ligand 10 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2023Quote: The surface plasmon resonance (SPR) experiments were performed at 25 °C on a BIAcore 2000 instrument (GE Healthcare). DsrC-trisulfide was immobilized on a NTA sensor chip (GE Healthcare ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... then stored at −20°C before purification by fast protein liquid chromatography (FPLC) (AKTA Purifier; GE Healthcare, UK) using a pre-packed HiLoad Superdex 30 26/600 column equipped with a UV detector ...
-
bioRxiv - Cell Biology 2024Quote: ... Live imaging was carried out in a chamber at 37°C using a Deltavision Core (Applied Precision™) microscope equipped with a CoolSnap HQ2 (Photometrics ...
-
bioRxiv - Neuroscience 2020Quote: ... the bound ligands were filtrated and collected on glass fiber papers (Whatman grade 934-AH, GE Healthcare, Pittsburgh, PA) with a M-24 Brandel filtration system (Brandel ...
-
bioRxiv - Cell Biology 2020Quote: ... Time-lapse imaging was carried out at 27 °C in an Environmental Chamber with a DeltaVision Spectris (Applied Precision) comprising an Olympus IX70 widefield inverted epifluorescence microscope ...
-
bioRxiv - Neuroscience 2021Quote: ... They were maintained within 37°C incubators at 5% CO2 in DMEM + high glucose (GE Healthcare Bio-Science, SH30022FS) supplemented with 9.09% fetal bovine serum (50 mL added to 500 mL DMEM ...
-
bioRxiv - Genomics 2019Quote: ... hybridization (at 68°C in 50% formamide) and washing was done following the instructions of the manufacturer (GE Healthcare). The riboprobes were obtained by rub-off transcriptions of linearized pBlueScript plasmids containing the full retrozymes in the presence of DIG-UTP (Roche Diagnostic GmbH ...
-
bioRxiv - Developmental Biology 2021Quote: ... dried for one hour at 80°C and exposed overnight to Phosphor screen in a cassette (GE healthcare, USA). Images were captured in Fujifilm FLA 5100 scanner (Japan ...
-
bioRxiv - Plant Biology 2021Quote: ... Two 2 ml aliquots were collected using GF/C glass microfiber filters (20 mm; Whatman, GE Healthcare Life Sciences), transferred to glass tubes ...
-
Inhibition of major histocompatibility complex-I antigen presentation by sarbecovirus ORF7a proteinsbioRxiv - Microbiology 2022Quote: ... C (W6/32) and rotated with 30 μl pre-equilibrated Protein G Sepharose 4 Fast Flow resin (GE healthcare) for 2 hours at 4°C ...
-
bioRxiv - Cell Biology 2022Quote: Living embryos were imaged at 21°C using a DeltaVision OMX V3 Blaze microscope (GE Healthcare Life Sciences, UK). The system was equipped with a 60x/1.42 NA oil UPlanSApo objective (Olympus Corp.) ...
-
bioRxiv - Biochemistry 2019Quote: RAD51 purification was carried out by chromatography at 4°C using the AKTA Pure Protein Purification System (GE Healthcare). For WT RAD51 ...
-
bioRxiv - Biophysics 2019Quote: ... its only cysteine at amino acid #265 near the flexible C terminus was labeled with Cy5 maleimide (GE healthcare) or AlexaFluor488 C5 maleimide (Thermo Fisher ...
-
bioRxiv - Biochemistry 2019Quote: ... Diluted protein samples in buffer C were loaded on a heparin HP 5 mL column (GE Healthcare, Chicago, IL) and protein was eluted with buffer D (25mM Tris pH 7.6 ...
-
bioRxiv - Molecular Biology 2020Quote: ... Reactions were incubated at 37 °C for 1 h and then passed through G-25 spin columns (GE Healthcare) according to the manufacturer’s instructions to remove unincorporated radioactivity ...
-
bioRxiv - Cell Biology 2021Quote: ... incubated for 1h at 4°C followed by incubation with protein A-sepharose beads (GE Healthcare #GE17-0780-01) for 2h at 4°C ...
-
bioRxiv - Biochemistry 2021Quote: ... RNA was then incubated with increasing amounts of ribosomal subunits/ribosomes for 15 min at 37°C before being rapidly filtrated through a cellulose nitrate membrane filter (0.2μm, GE Healthcare). The cellulose nitrate membranes were washed with 1 mL of cold TAKM5 buffer and placed into 10 mL of EcoLite (+ ...
-
bioRxiv - Biochemistry 2021Quote: ... The GST tag was removed by overnight cleavage at 4 °C using GST fusion 3C protease (Prescission, GE Healthcare). Fusion protease was removed using glutathione resin and the cleaved β2HA was collected in the flow-through ...
-
bioRxiv - Immunology 2020Quote: ... culture media was collected and incubated overnight at 4°C with nickel-Sepharose Excel (GE Healthcare 17-3712-01). His-tagged proteins were eluted from the nickel-Sepharose with 1 M imidazole in TrisCl pH 8.5 ...
-
bioRxiv - Molecular Biology 2021Quote: ... coli BL21 SI pRARE at 18 °C overnight and purified using a HisTrap FF 5-ml column (GE Healthcare) in standard buffers (50 mM HEPES-KOH pH 7.6 ...
-
bioRxiv - Biochemistry 2022Quote: All chromatography steps were performed at 4 °C using the ÄKTAxpress and ÄKTA pure protein purification systems (GE Healthcare). For affinity purification of the ADGRG4 construct ...
-
bioRxiv - Neuroscience 2023Quote: ... Appropriate antibodies were incubated with clarified lysate for overnight at 4°C and protein G sepharose beads (GE Healthcare) were incubated for 2h at 4°C ...
-
bioRxiv - Cell Biology 2022Quote: ... The extracted mononucleosome fraction was incubated for 2 h at 4°C with Protein G Sepharose beads (GE Healthcare), which were preincubated with rabbit polyclonal anti–chicken CENP-A antibody64 ...
-
bioRxiv - Immunology 2022Quote: The IgG antibody or Fab binding properties were analyzed at 25 °C using a Biacore 8K instrument (GE Healthcare) with 10 mM HEPES pH 7.4 ...
-
bioRxiv - Neuroscience 2023Quote: ... were run on 8% polyacrylamide gel and electrophoretically transferred onto nitrocellulose membrane (RPN303E, Hybond-C-extra, GE Healthcare Europe). The membranes were incubated at 4 °C under gentle shaking for 1 h in blocking buffer (1× TBS ...
-
bioRxiv - Molecular Biology 2023Quote: ... The remaining purification steps were carried out at 4 °C using an ÄKTA protein purification system (GE Healthcare/Cytiva) for column chromatography steps ...
-
bioRxiv - Molecular Biology 2023Quote: ... Reactions were incubated at 37 °C for 1 h and then passed through G-25 spin columns (GE Healthcare) according to the manufacturer’s instructions to remove unincorporated radioactivity ...
-
bioRxiv - Biophysics 2023Quote: ... Data collection was carried out at 20 °C using a Superdex200 Increase 5/150 analytical SEC column (GE Healthcare) equilibrated in the appropriate buffers (see Table S3 ...
-
bioRxiv - Biochemistry 2024Quote: ... All purification steps were performed at 4°C and the pre-packed amylose column (5ml Hi-Trap GE healthcare) was equilibrated with 25 mL Amylose column A Buffer ...
-
bioRxiv - Cancer Biology 2020Quote: ... Membranes were exposed to X-ray for 5-10 min using a biomolecular imager (ImageQuant LAS4000, GE Healthcare, USA). Relative cytokine content was determined after quantification of the dot intensity using ImageJ.
-
bioRxiv - Microbiology 2023Quote: ... 1 strip of 1 x 10 cm Whatman Grade 1 cellulose filter paper (GE Healthcare Life Sciences, Pittsburgh, PA) was added to a test tube containing 5mL of M63 media ...
-
bioRxiv - Biophysics 2023Quote: ... clarified 400,000 x g for 30 minutes and applied to a Superdex 200 Increase 10/300 GL (GE Healthcare) gel filtration column equilibrated in G-buffer containing 0.2 M ammonium acetate ...
-
bioRxiv - Bioengineering 2022Quote: ... Membranes were exposed to X-ray for 5-10 min using a biomolecular imager (ImageQuant LAS4000, GE Healthcare, USA). Relative cytokine content was determined after quantification of the dot intensity using ImageJ.
-
bioRxiv - Microbiology 2020Quote: ... The supernatant obtained by centrifugation (19,000 × g, 15 min, 4°C) was applied to a His SpinTrap column (GE Healthcare) previously equilibrated with buffer A ...
-
bioRxiv - Biophysics 2021Quote: ... Protein was purified via its C-terminal green fluorescence protein (GFP) tag using GFP nanobody coupled Sepharose Beads (GE Healthcare) and eluted by removing the GFP tag with the PreScission Protease ...
-
bioRxiv - Biochemistry 2021Quote: ... The soluble fraction was recovered by centrifugation (50,000 g, 20 min, 4°C) and applied to a HisTrap FF NiNTA column (GE Healthcare). After washing with buffer A (50 mM HEPES pH 7.5 ...
-
bioRxiv - Cell Biology 2020Quote: ... Titrations were performed at 25°C with a stirring speed of 750 rpm using the MicroCalTM iTC200 System (GE Healthcare). A total of 20 injections with 2 μL each and a spacing of 180 seconds were titrated into the 200 μL protein sample (25 mM Hepes pH 7.5 ...
-
bioRxiv - Molecular Biology 2020Quote: ... was pre-equilibrated for 1.5 hrs at 4°C with Sup6-150 buffer without inhibitors or DTT on an AKTA Purifier system (GE Healthcare). 500 μL lysate (2 mg protein ...
-
bioRxiv - Biochemistry 2019Quote: ... Following dialysis the E215C K490 construct was reacted for 4 h at 4°C with Cy3-maleimide (GE Healthcare, PA13131) at a motor/Cy3 dye ratio of 1:10 as previously described (Tomishige et al ...
-
bioRxiv - Cell Biology 2019Quote: ... 4°C) and the supernatant was applied to a 5ml HiTrap IgG Sepharose FF column (GE Healthcare, #28-9083-66). After washing with APC purification buffer ...
-
bioRxiv - Cell Biology 2019Quote: ... Sonicated lysate was cleared by centrifugation at 12,000g for 20 minutes at 4°C and then applied to pre-washed glutathione sepharose beads (GE healthcare) overnight at 4°C with rotation ...
-
bioRxiv - Cell Biology 2019Quote: HEK-293T were obtained from ATCC and cultured at 37°C and 5% CO2 in high-glucose DMEM (GE Healthcare) supplemented with 10% FBS (Atlanta Biologicals) ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were cleared by centrifugation at 48,284 g for 45 min at 4°C and loaded into a HisTrap FF cartridge (GE Healthcare). Proteins were eluted with 100 mM HEPES ...
-
bioRxiv - Biochemistry 2021Quote: ... After centrifugation at 27.000 xg for 30 min at 4 °C the supernatant was incubated with 4 mL Ni2+-Sepharose resin (GE Healthcare) for 1 hour at 4 °C under gentle agitation ...
-
bioRxiv - Biochemistry 2020Quote: ... BiP and Grp94 were expressed in Escherichia coli strain BL21* at 37°C and purified via Histrap column (GE Healthcare), by ion exchange on MonoQ column (GE Healthcare) ...
-
bioRxiv - Neuroscience 2020Quote: ... The supernatant was incubated at 4°C for 1 h with Ni-charged IMAC Sepharose 6 Fast Flow (GE Healthcare). The resin was then washed three times with His-A buffer (lysis buffer + 20 mM imidazole) ...
-
bioRxiv - Biochemistry 2021Quote: ... Lysates were clarified by centrifugation (15,000 g for 40 min at 4 °C) and incubated with 5 mL glutathione Sepharose 4B (GE Healthcare) for 1.5 hr at 4 °C with gentle shaking ...
-
bioRxiv - Microbiology 2020Quote: ... The lysate was centrifuged for 30 min at 30.000x g at 4 °C and loaded onto a Ni-NTA affinity chromatography column (HisTrap FF crude, GE Healthcare). His-tagged proteins were eluted with a linear gradient of buffer B (50 mmol L−1 Hepes at pH 8 ...
-
bioRxiv - Microbiology 2021Quote: ... The solution was centrifuged for 30 min at 38,000 × g and 4°C to remove precipitates and applied onto a 5 mL HisTrap HP column (GE Healthcare) equilibrated with buffer ParB3 ...
-
bioRxiv - Biophysics 2021Quote: ... and loaded at 4 °C with a flow rate of 0.5 ml min−1 onto a 5 ml HisTrap HP column (GE Healthcare) equilibrated with 50 mM Tris-HCl pH 8.0 ...