Labshake search
Citations for GE Life Sciences :
2951 - 3000 of 4868 citations for Glutathione Colorimetric Detection Kit 200 High Cuvettes since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2019Quote: ... Fractions containing FliD were pooled and applied to a HiLoad Superdex 200 16/600 column (GE Healthcare) equilibrated with 50 mM HEPES 150 mM NaCl pH 7 for FliDcj and 50 mM Tris 150 mM NaCl pH 8 for FliDpa and FliDsm.
-
bioRxiv - Microbiology 2020Quote: ... and size-exclusion chromatography was performed using a 24-ml Superdex 200 10/300 column (GE Healthcare) with 20 mM Tris (pH 7.5 ...
-
bioRxiv - Microbiology 2020Quote: ... The eluate was fractionated by gel filtration on a Superdex-200 Increase 10/300GL column (GE Healthcare) in buffer containing 30 mM HEPES ...
-
bioRxiv - Immunology 2020Quote: ... Proteins were further purified by size-exclusion chromatography using a HiLoad Superdex 200 16/600column (GE Healthcare).
-
bioRxiv - Immunology 2021Quote: ... The proteins were purified further by gel filtrations through a Superdex 200 26/60 column (GE Healthcare) equilibrated with gel filtration buffer ...
-
Bacterial killing by complement requires direct anchoring of Membrane Attack Complex precursor C5b-7bioRxiv - Immunology 2019Quote: ... Cy5-labelled proteins were purified by size-exclusion chromatography (SEC) on a Superdex 200 Increase (GE Healthcare) column with PBS and concentrated on a 30 kDa Amicon Tube ...
-
bioRxiv - Immunology 2021Quote: ... The eluted protein was further purified using a Superdex 200 Increase 10/300 GL column (GE Healthcare). The purity and size of the protein were analyzed by sulphate-polyacryl-amide gel electrophoresis (SDS-PAGE) ...
-
bioRxiv - Biochemistry 2020Quote: ... Proteins were concentrated in centrifugal concentrators and purified by size-exclusion chromatography (Superdex 200; GE Life Sciences) in gel filtration buffer (25 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biophysics 2020Quote: ... The concentrated protein sample was loaded on a Superdex 200 Increase 10/300 GL column (GE Healthcare) equilibrated with GF buffer (50 mM TRIS pH 7.4 ...
-
bioRxiv - Biophysics 2020Quote: ... The protein conjugate was purified on a Superdex 200 increase 10/30 gL column (GE Healthcare, US) with a flow rate of 0.5 mL/min with PBS as elution buffer ...
-
bioRxiv - Cell Biology 2021Quote: ... Stills with z-stacks 200 nm apart were taken using the DeltaVision Elite system microscope (GE Healthcare), 100x oil immersion objective ...
-
bioRxiv - Biochemistry 2022Quote: ... The protein was then concentrated and loaded onto a Superdex 200 Increase 10/300 column (GE Healthcare) pre-equilibrated with buffer containing 20 mM HEPES pH 7.4 ...
-
bioRxiv - Biochemistry 2022Quote: ... The elutions were concentrated to 1ml and loaded onto a HiLoad 16/600 Superdex 200 (GE Healthcare) column equilibrated in SEC buffer (10mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... Proteins were then subjected to size-exclusion chromatography using a Superdex 200 16/60 column (GE Healthcare) equilibrated with 20 mM HEPES ...
-
bioRxiv - Developmental Biology 2022Quote: ... cleaved on the column with 3C protease followed by size exclusion chromatography (HiLoad Superdex 200, GE Healthcare). The final product was collected in 25 mM HEPES pH 7.8 ...
-
bioRxiv - Cell Biology 2022Quote: ... Cell lysates were injected onto a Superdex 200 Increase 10/300 GL column (GE Healthcare Life Sciences). To slow Fe2+-oxidation and precipitation in equilibration buffer ...
-
bioRxiv - Microbiology 2022Quote: ... The product is further purified by gel filtration with Superdex 200 (GE Healthcare, Little Chalfont, United Kingdom) using the chromatography buffer (20 mM Tris-HCl ...
-
bioRxiv - Microbiology 2022Quote: ... The protein was concentrated and loaded onto a Superdex 200 16/60 size exclusion column (GE Healthcare) pre-equilibrated at 4 °C in SEC buffer ...
-
bioRxiv - Plant Biology 2022Quote: Analytical size-exclusion experiments were performed on a Superdex 200 Increase 10/300 GL column (GE Healthcare) equilibrated in 20□mM citric acid pH 5.0 ...
-
bioRxiv - Molecular Biology 2022Quote: Protein samples along with the gel filtration standard purchased from Bio-Rad were respectively applied to a size-exclusion chromatography column (Superdex-200 increase 10/300 GL, GE Healthcare) equilibrated with a buffer containing 10 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Plant Biology 2022Quote: ... and subjected for gel filtration by HiLoad® 16/600 Superdex® 200 pg column (GE Healthcare). Correct peaks were collected and the recombinant proteins were dialyzed in dialysis buffer (20 mM Tris-HCl pH 8.5 ...
-
bioRxiv - Plant Biology 2022Quote: ... and subjected for gel filtration by HiLoad® 16/600 Superdex® 200 pg column (GE Healthcare). The recombinant proteins were dialyzed in dialysis buffer (20 mM Tris-HCl pH 8.5 ...
-
bioRxiv - Plant Biology 2022Quote: Analytical SEC experiments were carried out on a Superdex 200 increase 10/300 GL column (GE Healthcare), preequilibrated in 20 mM sodium citrate ...
-
bioRxiv - Biochemistry 2024Quote: ... 200 µL of protein was injected into the Superdex 75 or Superdex200 size exclusion column (GE Healthcare) (volume less than 900 µL for preparative runs) ...
-
bioRxiv - Microbiology 2024Quote: Recombinant WT and mutant IN proteins were analyzed using Superdex 200 10/300 GL column (GE Healthcare) with the running buffer containing 20 mM HEPES (pH 7.5) ...
-
bioRxiv - Microbiology 2024Quote: ... The purified sample was further separated by HiLoad 16/600 Superdex 200 pg (GE Healthcare, 120 mL) (20 mM HEPES pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: Proteins were analyzed on a Superdex 200 10/300 GL column from GE healthcare (Chicago, IL, USA) equilibrated using a mobile phase containing 150 mM KCl and 50 mM Tris-HCl pH 7.6 run at 0.4 ml/min ...
-
bioRxiv - Neuroscience 2023Quote: ... and run over a 26/60 Sephacryl S-200 HR gel filtration column (GE Healthcare Life Sciences) equilibrated in 50 mM Tris-HCl ...
-
bioRxiv - Molecular Biology 2023Quote: ... His6-SUMO-AGO1 NcGN was further purified by application on a Superdex 200 16 600 (GE Healthcare) size exclusion chromatographic column connected to an Äkta Purifier system (GE Healthcare ...
-
bioRxiv - Biochemistry 2022Quote: ... The protein was further purified by SEC using a Superdex 200 Increase 10/300 column (GE Healthcare) equilibrated with Buffer B ...
-
bioRxiv - Biochemistry 2022Quote: ... For crystallography proteins were purified further via size-exclusion chromatography (HiLoad 16/600 Superdex 200, GE Healthcare) in 20 mM HEPES ...
-
bioRxiv - Plant Biology 2023Quote: ... and the eluted proteins were further purified via gel filtration chromatography with a superdex 200 (GE Healthcare) column ...
-
bioRxiv - Immunology 2023Quote: ... Monomeric antibodies were purified by size exclusion chromatography on a Superdex 200 26/600 column (GE Healthcare) in 25 mM Citrate ...
-
bioRxiv - Biochemistry 2022Quote: ... Eluted proteins were pooled and concentrated before separation on a Superdex 200 16/60 column (GE Healthcare) equilibrated in GF2 Buffer (50 mM Tris-HCl pH 7.5 ...
-
Phosphorylation controls spatial and temporal activities of motor-PRC1 complexes to complete mitosisbioRxiv - Biochemistry 2023Quote: ... Recombinant proteins were then concentrated and loaded on a Superdex 200 Increase 10/300 GL (GE Healthcare) pre-equilibrated in size-exclusion chromatography buffer ...
-
bioRxiv - Genetics 2023Quote: ... Protein containing fractions were further purified by size exclusion chromatography using Superdex 200 10/300 (GE Healthcare) gel-filtration column in SEC buffer (20 mM HEPEs pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... and further purified by gel filtration chromatography on HiLoad 16/600 Superdex 200 pg column (GE Healthcare) in 25 mM Tris-HCl ...
-
bioRxiv - Cell Biology 2022Quote: ... The eluted TEAD4-YBDprotein was purified via size-exclusion chromatography using a Superdex 200 column (GE Healthcare). Purified TEAD4-YBD was concentrated to 2 mg/mL in a buffer containing 20 mM Tris (pH 8.0) ...
-
bioRxiv - Biophysics 2023Quote: ... The cleaved protein was applied to a Superdex 200 Increase 10/300 GL column (GE Healthcare, USA) pre-equilibrated with gel filtration buffer (150 mM NaCl ...
-
bioRxiv - Biophysics 2023Quote: ... Sample was then applied to SEC using a HiLoad 16/600 Superdex 200 pg (GE Life Sciences) on an Akta Pure (GE Life Sciences ...
-
bioRxiv - Microbiology 2023Quote: ... Peak fractions were collected and directly loaded onto a Superdex 200 16/600 pg column (GE healthcare) preequilibrated in 300 mM NaCl and 50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2023Quote: ... the sample was purified by size-exclusion chromatography using a Superdex 200 (16/600) column (GE Healthcare) in equilibrated in buffer 20 mM Tris-HCl pH 8.0 ...
-
bioRxiv - Biochemistry 2023Quote: ... and loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris [pH 8.0] ...
-
bioRxiv - Biochemistry 2023Quote: ... The dialyzed proteins were concentrated and purified by SEC (HiLoad Superdex-200 16/600 column, GE Healthcare) into tau buffer ...
-
bioRxiv - Immunology 2023Quote: ... 10% glycerol) and further purified by size-exclusion chromatography on a Superose 200 Increase column (GE Healthcare).
-
bioRxiv - Cell Biology 2023Quote: ... and loaded onto a 24 mL Superdex 200 10/300 GL (GE Healthcare, Cat# 17-5174-01) size exclusion column equilibrated in 20 mM Tris [pH 8.0] ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... and further purified by size-exclusion chromatography on a Superdex 200 10/300 column (GE Life Sciences) in SEC buffer (20 mM HEPES pH 7.6 ...
-
bioRxiv - Microbiology 2023Quote: ... followed by size exclusion chromatography (SEC) using a Superdex 200 Increase 10/300 GL column (GE HealthCare). Protein purity was assessed by Coomassie-stained SDS-PAGE ...
-
bioRxiv - Cell Biology 2023Quote: ... followed by size exclusion chromatography using a Superdex 200 10/300 GL column (GE Healthcare, Catalog # 17517501). The purification buffer was 150 mM NaCl ...
-
bioRxiv - Biochemistry 2023Quote: ... and then loaded on a size exclusion chromatography (SEC) column (Superdex 200 Increase 10/300, GE Healthcare) pre-equilibrated with 25 mM HEPES pH 7.4 ...