Labshake search
Citations for GE Life Sciences :
2701 - 2750 of 6253 citations for Cow Rho Associated Protein Kinase 1 ROCK1 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... The protein was further purified by gel filtration with a Superose 6 10/300 GL column (GE Healthcare). hPCNA was expressed and purified as described in (Duffy et al ...
-
bioRxiv - Biochemistry 2020Quote: All of the proteins characterized here eluted as homodimers as determined by a calibrated Superdex 75 (GE Healthcare) gel filtration chromatography column (25 mM Tris ...
-
bioRxiv - Biochemistry 2020Quote: Protein (450 μg/100 μL) was loaded on a Superdex™ 200 HR 10/30 column (GE Healthcare) equilibrated with PBS (140 mM NaCl ...
-
bioRxiv - Biochemistry 2020Quote: ... The protein was further purified by gel filtration chromatography on a Superose 6 10/300 column (GE Healthcare) in a buffer containing 25 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2020Quote: ... The tag-free protein was further purified through ion-exchange chromatography on a Heparin HP column (GE Healthcare) and size exclusion chromatography on a 16/600 Superdex 200 pg column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2020Quote: ... The protein was further purified by gel filtration chromatography on a Superose 6 10/300 column (GE Healthcare) in a buffer containing 25 mM Tris-HCl ...
-
bioRxiv - Biochemistry 2020Quote: ... The protein was further purified by gel-filtration chromatography on a Superdex 200 16/60 column (GE Healthcare) in Cas9 storage buffer (20 mM Tris-Cl ...
-
bioRxiv - Neuroscience 2020Quote: ... re-suspended in ultrapure water and pre-cleared with recombinant protein A sepharose (GE Healthcare, Chicago, IL, USA). Immunoprecipitation of Aβ species from the media was performed with the monoclonal anti-Aβ clone W0-2 (MABN10 ...
-
bioRxiv - Cell Biology 2020Quote: ... the labeled protein was separated from the solution by size exclusion chromatography using PD MiniTrap G25 (GE Healthcare). PLCγ1 nSH2-cSH2-SH3 and truncations were labeled with CoA 647 (NEB ...
-
bioRxiv - Biochemistry 2021Quote: ... The protein was subsequently loaded into an ion exchange column (HiTrap® SP FF GE Healthcare Life Sciences), pre-equilibrated in the SP buffer A to remove 6His-ZB tag and uncleaved protein ...
-
bioRxiv - Biochemistry 2021Quote: ... The protein was purified from conditioned medium by cation exchange chromatography on a SP sepharose column (GE healthcare) in 50 mM Tris ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins separated by SDS-PAGE were detected following the manufacturer’s guidelines (GE Healthcare ECL Western Blotting detection system) and the images collected using a Chemidoc imaging system (BioRad Laboratories).
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were further purified on a HiLoad 16/600 Superdex 75pg or 200pg gel-filtration columns (GE Healthcare). To obtain stoichiometric MLL1RWSAD complex ...
-
bioRxiv - Biochemistry 2020Quote: ... coli BL21 cells as described previously.13 The protein was purified using glutathione-Sepharose 4B beads (GE Healthcare) concentrated and flash-frozen in GST buffer [25 mM Tris (pH 7.5) ...
-
bioRxiv - Bioengineering 2021Quote: The His-tag affinity-purified GINKO1 protein was further applied on the size exclusion chromatography Superdex200 (GE Healthcare) column pre-equilibrated with 25 mM Tris pH 7.5 ...
-
bioRxiv - Cell Biology 2021Quote: ... while the supernatant of GST-fusion protein homogenates were loaded onto pre-equilibrated glutathione SepharoseTM beads (GE healthcare), and incubated on an orbital rotator for an hour in cold room.
-
bioRxiv - Plant Biology 2020Quote: ... Total proteins were separated by SDS-PAGE and transferred to a polyvinylidene difluoride membrane (GE Healthcare Life science). Equal loading was validated using Coomassie Brilliant Blue staining of the membrane ...
-
bioRxiv - Microbiology 2020Quote: ... All protein lysates were separated on 12% SDS-polyacrylamide gels and transferred to polyvinyl difluoride (PVDF, GE Healthcare) membranes ...
-
bioRxiv - Plant Biology 2021Quote: ... pastoris X-33 and the secreted proteins were purified by affinity chromatography (HiTrap Chelating HP column) (GE Healthcare). Eluted proteins were copper saturated with Cu(II)SO4 and applied to a 120 mL Superdex 75/16 column (GE Healthcare ...
-
bioRxiv - Microbiology 2021Quote: ... The supernatant was maintained at 4°C for protein purification with a prepared HisTrap HP column (GE Healthcare). Purified protein samples were concentrated using an Amicon 4 centrifugal filtration tube centrifuged for 5 min at 3600 rcf (4 °C) ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... Eluted protein was then applied to size-exclusion chromatography (Superdex 200 Increase 10/300 GL column, GE Healthcare) with the buffer containing 25 mM MES pH 6.0 ...
-
bioRxiv - Microbiology 2021Quote: ... FLAG epitope-tagged protein levels were visualized using the Amersham ECL Western blotting detection reagent (GE Healthcare, #GERPN2209). In a parallel gel ...
-
bioRxiv - Molecular Biology 2020Quote: ... Recombinant NS1-6xHis protein was further purified by gel filtration using an AKTA pure chromatograph (GE Healthcare, USA). An XK 16/60 Chromatographic Column ...
-
bioRxiv - Molecular Biology 2020Quote: ... Lysates were clarified by centrifugation and GST-tagged protein were isolated on glutathione sepharose 4B resin (GE Healthcare) at 4°C for 2 hours ...
-
bioRxiv - Plant Biology 2021Quote: ... 20X concentrated protein extract (10 ml) was loaded in an anionic-exchange Q-sepharose column (GE Healthcare, USA) previously equilibrated with 20 mM Tris-HCl pH 7.4 ...
-
bioRxiv - Microbiology 2020Quote: ... Eight days post transfection the supernatant was loaded on the HiTrap protein G HP 1ml column (GE Healthcare) in binding buffer (20 mM sodium phosphate pH 7.0 ...
-
bioRxiv - Neuroscience 2021Quote: ... The supernatant was analyzed by SDS-PAGE and proteins were transferred to a nitrocellulose membrane (GE Healthcare, #BA85). Membranes were incubated for 1 h in a blocking solution (Tris-buffered saline (TBS ...
-
bioRxiv - Cancer Biology 2020Quote: ... Protein was then purified by gel filtration using a Superdex 200 26/600 GL column (GE Life Sciences) before cleaving the His6-SUMO tag with ULP1 enzyme ...
-
bioRxiv - Cancer Biology 2020Quote: ... Proteins were resolved using SDS-PAGE gels and transferred to nitrocellulose membranes (GE Healthcare Life Sciences, cat#10600001) as previously described in [8] ...
-
bioRxiv - Cell Biology 2021Quote: ... The proteins were further purified by size exclusion chromatography (SEC; HiLoad 16/600 Superdex 200 pg, GE Healthcare) in 50 mM phosphate pH 8.0 ...
-
bioRxiv - Cell Biology 2021Quote: ... GST-Bro1V fusion protein and mutants thereof were purified using the Glutathione Sepharose 4B (GE Healthcare, United Kingdom), treated with AcTEV protease (Thermo Fisher Scientific ...
-
bioRxiv - Biochemistry 2022Quote: ... the proteins were further purified by size exclusion chromatography (Superdex-75 10/300 GL column; GE Life Sciences) and judged greater than 95% pure by SDS-PAGE analysis.
-
bioRxiv - Cell Biology 2022Quote: ... and 0.1 mg protein were loaded on a Superdex 200 10/300 GL size-exclusion column (GE Healthcare) connected to an ÄKTA pure (GE Healthcare ...
-
bioRxiv - Biochemistry 2022Quote: ... The concentrated protein was subjected to size exclusion chromatography on Superose 6 increase 10/300 column (GE Healthcare).
-
bioRxiv - Biophysics 2022Quote: ... Labeled proteins were separated from free dye molecules by gel filtration using a Superdex 200 column (GE Healthcare)56.
-
bioRxiv - Biochemistry 2022Quote: ... Concentrated protein for Cryo-EM was loaded over a HiLoad 26/600 Superdex 200 pg column (GE Healthcare) using SEC Buffer (25mM HEPES pH 7.2 ...
-
bioRxiv - Biochemistry 2022Quote: ... Then the protein was purified by gel-filtration chromatography using a Superose 6 gel filtration column (GE Healthcare) pre-equilibrated with HBS buffer (10 mM HEPES ...
-
bioRxiv - Biophysics 2022Quote: ... Then the proteins were purified from the lysate with the Ni2+-NTA column of ÄKTA Pure (GE healthcare). Then the proteins were biotinylated using Avidity biotinylation kit and recommended protocol ...
-
bioRxiv - Biochemistry 2022Quote: ... Protein was further purified with gel filtration on a Hi-load 16/60 Superdex-75 column (GE Healthcare) in 25 mM Trizma (pH 7.5) ...
-
bioRxiv - Biochemistry 2022Quote: ... The eluted protein was diluted with lysis buffer before application to a 5ml HiTrap STREP column (GE Healthcare), washed with lysis buffer and eluted using buffer supplemented with 2 mM Desthiobiotin ...
-
bioRxiv - Biochemistry 2022Quote: ... The eluted protein was concentrated and applied to a Superose 6 Increase 10/300 GL column (GE Healthcare) in the same buffer.
-
bioRxiv - Immunology 2022Quote: IgG was purified by separation over a HiTrap Protein A HP Antibody Purification Column (GE Life Sciences, 17040203) fitted to a GE Life Sciences Akta Purifier 10 HPLC ...
-
bioRxiv - Neuroscience 2022Quote: ... Proteins of interest were visualized with the Amersham ECL Detection Reagents (GE Healthcare by SIGMA, Cat. No. RPN2105) or LiteAblot TURBO Extra-Sensitive Chemioluminescent Substrate (EuroClone ...
-
bioRxiv - Microbiology 2022Quote: ... The protein was then further purified by gel filtration using Superose 6 increase 10/300 column (GE Healthcare) in 20 mM Tris pH 8.0 ...
-
bioRxiv - Molecular Biology 2022Quote: ... Protein solution was run at room temperature on a Superdex 75 10/300 GL (GE Healthcare, Piscataway, NJ) column with 2 mg/ml gD1 and a mobile phase composed of Tris- HCl at pH 7.5 ...
-
bioRxiv - Biochemistry 2022Quote: ... The protein was run over a size exclusion column (GE Healthcare HiPrep 26/60 Sephacryl S-300 HR) in sizing buffer (50 mM Tris-HCl pH = 8.0 ...
-
bioRxiv - Biochemistry 2020Quote: ... protein digestion was concentrated and applied to a HiLoad™ 16/600 Superdex™ 75pg column (GE Healthcare) in 20 mM Hepes pH 7.5 ...
-
bioRxiv - Microbiology 2020Quote: ... 500 µl of freshly purified protein was loaded on a Superdex 200 10/300 GL column (GE Healthcare) equilibrated with Buffer A ...
-
bioRxiv - Biochemistry 2021Quote: ... The P5CS proteins were further purified through HiLoad 16/600 Superdex 200 pg gel-filtration chromatography (GE Healthcare) in column buffer (25 mM HEPES pH 7.5 and 100 mM KCl) ...
-
bioRxiv - Plant Biology 2021Quote: ... the purified protein was loaded on an analytical size exclusion column (SEC, superdex200 10/300, GE Healthcare, USA) pre-equilibrated with buffer containing 25mM Tris (pH 8.0) ...