201 - 250 of 4368 citations for PRG2 Protein Human Recombinant His Tag HPLC verified since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Microbiology 2021Quote: ... Recombinant protein was purified by chromatography using a Nickel-loaded Hitrap Chelating HP column (GE Healthcare). Unbound material was extensively washed using Tris 20mM pH8 ...
-
bioRxiv - Microbiology 2020Quote: ... Recombinant protein was purified using a 1 ml HisTrap FF column (GE Healthcare, Amersham, United Kingdom) with imidazole gradient elution ...
-
bioRxiv - Neuroscience 2020Quote: ... The recombinant proteins were purified by Ni2+-affinity chromatography using Histrap HP FPLC columns (GE Healthcare) and a size-exclusion chromatography using a HiLoad 16/60 200 PG column (GE Healthcare ...
-
bioRxiv - Immunology 2022Quote: ... Recombinant IgG mAbs were purified using HiTrap Protein A columns (Cytiva/GE Healthcare Life Sciences, 17040303).
-
bioRxiv - Biochemistry 2020Quote: ... The recombinant proteins were purified from the filtrated supernatants using a HisTrap excel column (GE Healthcare). The purified proteins were biotinylated in vitro using the BirA enzyme in the presence of 0.5 mM Biotin and 10 mM ATP ...
-
bioRxiv - Neuroscience 2022Quote: ... recombinant proteins were then eluted from a HiLoad 16/600 Superdex 200 pg column (GE Healthcare) equilibrated with 20 mM Tris-HCl (pH 7.5) ...
-
bioRxiv - Immunology 2023Quote: ... Recombinant IgG was harvested and purified after 6 days with protein G sepharose beads (GE Healthcare), dialyzed in PBS ...
-
bioRxiv - Synthetic Biology 2023Quote: ... Recombinant proteins were then purified by 1 mL Ni Sepharose (17-5318-01, GE Healthcare, USA). Columns were sequentially washed with 20 mL buffer 1 and 10 mL buffer 2 (in mM ...
-
bioRxiv - Biochemistry 2020Quote: ... The tag-free protein was further purified through ion-exchange chromatography on a Heparin HP column (GE Healthcare) and size exclusion chromatography on a 16/600 Superdex 200 pg column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2021Quote: ... His6-tag free Ape1 protein was then loaded onto a Superdex 200 10/300 GL column (GE Healthcare) in 20 mM Tris-HCl pH 7.0 ...
-
bioRxiv - Plant Biology 2024Quote: ... The tag-free CMT2 proteins were further purified through ion-exchange chromatography on a Heparin column (GE Healthcare) and size-exclusion chromatography on a 16/600 Superdex 200 pg column (GE Healthcare) ...
-
bioRxiv - Biochemistry 2022Quote: ... The recombinant proteins were further purified by gel filtration on an ÄKTA Pure fast protein liquid chromatography (FPLC) system (GE Healthcare Life Sciences). The principal peaks were collected ...
-
bioRxiv - Biochemistry 2024Quote: ... The recombinant proteins were further purified by gel filtration on an ÄKTA Pure fast protein liquid chromatography (FPLC) system (GE Healthcare Life Sciences). The principal peaks were collected ...
-
bioRxiv - Molecular Biology 2020Quote: ... Hi-Trap Q (GE Healthcare), and Superdex 200 columns (GE Healthcare) ...
-
bioRxiv - Cell Biology 2021Quote: ... Full-length human αSyn cDNA containing an N-terminal myc epitope-tag was inserted into a modified pGEX-KG vector (GE Healthcare), after a TEV protease recognition site to allow cleavage from GST (myc-αSyn contains an extra N-terminal glycine after cleavage with TEV protease) ...
-
bioRxiv - Biochemistry 2020Quote: ... Enc:EncFtn protein complex sample was loaded onto a 20 ml anion exchange column (Hi-Prep Q HP, GE Healthcare) pre-equilibrated with Buffer QA (50 mM Tris ...
-
bioRxiv - Microbiology 2020Quote: ... The His-tagged GlpQ protein was purified by Ni2+-affinity chromatography using a 1 ml HisTrap column (GE Healthcare) followed by size exclusion chromatography on a HiLoad 16/60 Superdex 200 pg column (GE Healthcare ...
-
bioRxiv - Microbiology 2021Quote: ... The proteins were further purified by Ni-NTA immobilized metal-affinity chromatography using His-Trap HP columns (GE Healthcare) followed by size exclusion chromatography ...
-
bioRxiv - Biochemistry 2024Quote: Native and selenomethionine-substituted BT4246 proteins were purified using a 5 ml Hi-Trap metal affinity cartridge (GE Healthcare) according to the manufacturer’s instructions ...
-
bioRxiv - Immunology 2023Quote: ... Protein TLR827–827-PA-His was purified with IgG beads (Cat#17-0969-01, GE Healthcare, Connecticut, CT, USA) and resuspended in 200 μl of NT2 buffer 66 and used for miRNA-protein co-IP ...
-
bioRxiv - Biochemistry 2023Quote: ... most of the proteins were loaded onto a Hi-trap Q HP anion exchange column (GE Healthcare, cat. 17115401). The final purification step involved using a size exclusion column ...
-
bioRxiv - Microbiology 2024Quote: ... Supernatant containing the solubilised membrane proteins was pooled and applied to a His-TRAP nickel affinity column (GE Healthcare) using an ÄKTA Protein Purification System (Cytiva) ...
-
bioRxiv - Microbiology 2021Quote: Cell wall binding assays of recombinant PBP1 proteins fluorescently labelled with Cy2 bis- reactive dye (GE Healthcare) were performed as previously described (Bottomley et al. ...
-
bioRxiv - Microbiology 2021Quote: ... recombinant protein was purified from the filtered culture supernatant using HisTrap Excel columns (GE Healthcare Life Sciences). Each column was stored in 20% ethanol and washed with 5 column volumes (CV ...
-
bioRxiv - Molecular Biology 2020Quote: ... The GST part was cleaved off from the recombinant protein using PreScission Protease (GE Healthcare Life Sciences) according to the manufacturer’s instructions ...
-
bioRxiv - Molecular Biology 2022Quote: ... 250 µl of antiserum were coupled to 60 µl of recombinant Protein A Sepharose (rPAS, GE Healthcare). Antibodies bound beads were washed three times in CPB and supplemented with 6 µl fresh rPAS ...
-
bioRxiv - Pathology 2020Quote: ... Recombinant proteins were purified with a Ni-NTA resin and Q-Sepharose™ (GE Healthcare, Mississauga, ON). Endotoxin was removed using the Pierce™ High-Capacity Endotoxin Removal Resin (ThermoFisher Scientific ...
-
bioRxiv - Microbiology 2021Quote: ... recombinant proteins were purified by nickel affinity chromatography using HisTrap Column (GE Healthcare Life Sciences Pittsburgh, PA). Rat polyclonal antisera against L ...
-
bioRxiv - Molecular Biology 2020Quote: ... 250 μl of antiserum were coupled to 50 μl of recombinant protein A-sepharose (rPAS, GE Healthcare). Antibody beads were washed three times in PBS and treated with 5 μl fresh rPAS ...
-
bioRxiv - Microbiology 2024Quote: Recombinant WT and mutant IN proteins were analyzed using Superdex 200 10/300 GL column (GE Healthcare) with the running buffer containing 20 mM HEPES (pH 7.5) ...
-
bioRxiv - Cell Biology 2023Quote: ... Supernatants containing soluble recombinant protein were pulled-down with Glutathione (GSH) Sepharose 4FastFlow (GE Healthcare, 17-5132) for 3h at 4°C with gently rocking ...
-
bioRxiv - Molecular Biology 2023Quote: ... 170 µl of antiserum was coupled to 40 µl of recombinant Protein A Sepharose (rPAS, GE Healthcare). Antibodies bound beads were washed extensively in CPB and supplemented with 4 µl fresh rPAS ...
-
bioRxiv - Plant Biology 2022Quote: ... The recombinant protein GST-LSH10 was purified using Glutathione Sepharose 4B beads (GE Healthcare, 17-0756-01) according to the manufacturer’s protocol ...
-
Phosphorylation controls spatial and temporal activities of motor-PRC1 complexes to complete mitosisbioRxiv - Biochemistry 2023Quote: ... Recombinant proteins were then concentrated and loaded on a Superdex 200 Increase 10/300 GL (GE Healthcare) pre-equilibrated in size-exclusion chromatography buffer ...
-
bioRxiv - Microbiology 2024Quote: ... The recombinant proteins were purified using a GE Healthcare HisTrap HP nickel column (GE HealthCare, Chicago, US). Purified proteins were dialyzed at 4 °C for 24 hours using a MW14000 dialysis membrane (Biosharp ...
-
bioRxiv - Cell Biology 2021Quote: Tag-free syndapin I and III were generated by expressing both proteins in the pGEX-6P vector (GE Healthcare) and cutting of the GST tag from purified proteins using PreScission protease (GE Healthcare ...
-
bioRxiv - Immunology 2022Quote: ... The antibodies were purified from Expi293 cell supernatant by high-performance liquid chromatography (HPLC) coupled with HiTrap Protein A HP columns (Cytiva, formerly GE Healthcare). Monoclonal antibodies were then dialyzed by SnakeSkin dialysis tubing (10K MWCO ...
-
bioRxiv - Immunology 2024Quote: ... using an AKTAmicro HPLC system (GE Healthcare). HPLC Buffer A (0.1% TFA ...
-
bioRxiv - Biochemistry 2020Quote: The purified rhGFAT2-his protein was subjected to a size exclusion chromatography using a Superdex 200 column (GE Healthcare, USA). The column was equilibrated with 1 CV of 20 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biophysics 2020Quote: ... the proteins were first purified from bacterial cell lysates using His-Trap HP (Ni-NTA) columns (GE Healthcare Life Sciences), as per the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... The proteins were further purified by size exclusion chromatography (Hi-load 16/60 Superdex 200 column, GE Healthcare Life Sciences) in a buffer (20 mM Tris-HCl ...
-
bioRxiv - Biophysics 2024Quote: ... All proteins were purified by Ni-NTA affinity chromatography using a 1 mL His Trap column (GE Healthcare Life Science). The column was equilibrated with balance buffer (50 mM PBS pH 7.5 and 150 mM NaCl ...
-
bioRxiv - Microbiology 2022Quote: ... and His-trap column (GE healthcare) previously equilibrated with Lysis Buffer ...
-
bioRxiv - Neuroscience 2020Quote: ... A His-capture kit (GE Healthcare) was used to immobilize anti-His antibodies on CM5 chips (as recommended by the manufacturer) ...
-
bioRxiv - Biophysics 2023Quote: ... Hi-Trap Heparin HP (GE Healthcare), and Superdex 200 10/300 GL columns (GE Healthcare) ...
-
bioRxiv - Microbiology 2021Quote: ... recombinant proteins were further purified by anion-exchange chromatography on a Resource Q column (GE Healthcare, United States) that was pre-equilibrated with buffer A (20 mM Tris–HCl ...
-
bioRxiv - Neuroscience 2020Quote: ... re-suspended in ultrapure water and pre-cleared with recombinant protein A sepharose (GE Healthcare, Chicago, IL, USA). Immunoprecipitation of Aβ species from the media was performed with the monoclonal anti-Aβ clone W0-2 (MABN10 ...
-
bioRxiv - Molecular Biology 2020Quote: ... Recombinant NS1-6xHis protein was further purified by gel filtration using an AKTA pure chromatograph (GE Healthcare, USA). An XK 16/60 Chromatographic Column ...
-
bioRxiv - Immunology 2020Quote: ... Recombinant proteins were purified directly from the filtered culture supernatants using HisTrap Excel columns (GE Healthcare Life Sciences). Each column was stored in 20% ethanol and washed with 5 column volumes (CV ...
-
bioRxiv - Neuroscience 2022Quote: ... The recombinant protein in the supernatant of the cell lysate was mixed with Glutathione Sepharose resin (GE Healthcare) and the mixture was washed extensively in 10mM HEPES pH 7.3 ...